The Load-Bearing Capacity Assessment of GFRP Foundation Piles for Transmission Line Poles Using Experimental Tests and Numerical Calculations

被引:0
|
作者
Derlatka, Anna [1 ]
Labocha, Slawomir [2 ]
Lacki, Piotr [1 ]
机构
[1] Czestochowa Tech Univ, Fac Civil Engn, Dabrowskiego 69 Str, PL-42201 Czestochowa, Poland
[2] Acad Silesia, Fac Architecture Bldg & Appl Arts, Rolna 43 Str, PL-40555 Katowice, Poland
来源
APPLIED SCIENCES-BASEL | 2025年 / 15卷 / 04期
关键词
glass fibre-reinforced polymer; GFRP; foundation; pile; transmission line poles;
D O I
10.3390/app15042231
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Featured Application The proposed solution to monopiles made of glass fibre reinforcement polymer composite materials can be implemented in the foundation construction of low- and medium-voltage overhead transmission lines. The disadvantage of GFRP monopiles is their high deformability. The great advantages of GFRP monopiles, related to their very low dead weight, easy material processing, corrosion resistance, and dielectric properties, can be used in the case of low-voltage line poles.Abstract This article proposes a novel tube foundation intended for use under transmission line poles. The glass fibre reinforcement polymer (GFRP) piles were driven into sand. A steel tube pole, approximately 6 m high, was mounted on the foundation. The analysed foundations were designed as a monopile to be implemented in the construction of low- and medium-voltage overhead transmission lines. Experimental field tests of innovative piles made of the composite material were carried out on a 1:1 scale. The aim of this work was to develop an isotropic material model treating the GFRP composite as homogeneous. This approach does not fully reproduce the anisotropic behaviour of the composite, but it allows for the engineering design of structures made of the composite material. Laboratory tests in the form of a static tensile test on the samples and a tensile test on the rings cut from a hollow section were performed. The results of the experimental tests and FEM models of the GFRP rings and monopile embedded in sand were compared. The ultimate limit state (ULS) and serviceability limit state (SLS) of the analysed pile were assessed as 14.4 and 9.6 kNm, respectively. The developed numerical model, based on FEM, allows for the load-bearing capacity of the monopile made of GFRP to be reliably determined. From an engineering point of view, the developed numerical model of the GFRP material can be used to calculate the pile load-bearing capacity using engineering software that has limited capabilities in defining material models.
引用
收藏
页数:22
相关论文
共 44 条
  • [41] Assessment of bearing capacity and permeability of foundation rocks at the Gumustas Waste Dam Site (NE Turkey) using empirical and numerical analysis
    Selcuk Alemdag
    Arabian Journal of Geosciences, 2015, 8 : 1099 - 1110
  • [42] Considering realistic weld imperfections in load bearing capacity calculations of ring-stiffened shells using the analytical numerical hybrid model
    Pasternak, H.
    Li, Z.
    Stapelfeld, C.
    Launert, B.
    Jaeger-Canas, A.
    STABILITY AND DUCTILITY OF STEEL STRUCTURES 2019, 2019, : 882 - 889
  • [43] Numerical analysis of load-bearing capacity of shear-strengthened reinforced concrete beams without shear reinforcement using side-bonded CFRP sheets
    Nguyen, Ngoc Tan
    Du, Duc Hieu
    Bui, Quang Trung
    Nguyen, Dinh Thanh
    EUROPEAN JOURNAL OF ENVIRONMENTAL AND CIVIL ENGINEERING, 2025, 29 (05) : 859 - 880
  • [44] Exceptional load-bearing capability of Al FPCB/Cu FPCB lap joints using instantaneous laser-based large area facial soldering: Experimental and numerical investigations
    Kim, Seoah
    Kim, YehRi
    Jo, Eunjin
    Lee, Hyeon-Sung
    Mhin, Sungwook
    Lee, Tae-Young
    Yoo, Sehoon
    Ko, Yong-Ho
    Kim, Dongjin
    JOURNAL OF MATERIALS RESEARCH AND TECHNOLOGY-JMR&T, 2024, 30 : 6668 - 6685