A novel in-flight geometric calibration method for mapping cameras with composite-frame

被引:0
|
作者
Fang, Yong [1 ,2 ]
Wang, Gang [3 ]
Hu, Haiyan [1 ,2 ]
Gao, Li [1 ,2 ]
Zhang, Li [1 ,2 ]
Gong, Hui [1 ,2 ]
Wang, Tao [2 ,4 ]
Ma, Sen [2 ,4 ]
机构
[1] Xian Res Inst Surveying & Mapping, Xian 710054, Peoples R China
[2] State Key Lab Geoinformat Engn, Xian 710054, Peoples R China
[3] Nanjing Jianbing Aerosp Remote Sensing Informat Te, Nanjing 211106, Peoples R China
[4] Changan Univ, Coll Geol Engn & Geomat, Xian 710054, Peoples R China
关键词
Integrated arrays imaging system; In-flight calibration; Distortion corrected; Composite large frame; Imaging error compensation;
D O I
10.1016/j.measurement.2025.117048
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The new aerial mapping cameras usually have a large-format frame to satisfy the dual demand of a wide field-ofview (FOV) and high resolution. One of the main techniques is to utilize a composite-frame composed of integrated multiple arrays. However, in-flight geometric calibration (IGC) is still a challenge for ensuring the metric accuracy of composite-frame cameras. In this paper, we propose a new method for IGC of a novel compositeframe mapping camera, and verify its accuracy and applicability. The method mainly consists of geometric test field design and crossing route self-calibrating bundle adjustment with additional parameters. It can overcome the strong correlation of the solved parameters, which occurs among the additional parameters, the internal orientation, the external orientation element, and other unknowns. This method can also avoid the problems of aggravated computation results or non-convergence. Using a 1200 m x 1200 m test field on a flat terrain, we tested the method on the composite-frame mapping camera DMZ II in 2021. The results demonstrate that the method fulfills the calibration requirements of the composite-frame camera, and can overcome the negative effects of flat terrain conditions. The calibration accuracy reaches the level of 0.1 pixel, corresponding to the geometric error of less than 1 um, and the parameters can effectively describe the distortion distribution of the composite-frame. It was successfully applied to practical aerial photogrammetry engineering in Jiayuguan area in 2022. In addition, the algorithm for generating distortion free images after calibration has been updated, using indirect correction combined with free network adjustment to suppress the random error caused by various factors over long periods of time, in order to improve the quality and robustness of computational imaging. The method offers a reliable and efficient way for IGC of large-format aerial cameras with composite frames, greatly reducing the requirements for ground calibration fields, while also providing valuable references for other aerial and space mapping cameras that adopt integrated arrays imaging mechanism.
引用
收藏
页数:22
相关论文
共 50 条
  • [21] THE FUTURE SPACEBORNE HYPERSPECTRAL IMAGER ENMAP: ITS IN-FLIGHT RADIOMETRIC AND GEOMETRIC CALIBRATION CONCEPT
    Schneider, M.
    Mueller, R.
    Krawzcyk, H.
    Bachmann, M.
    Storch, T.
    Mogulsky, V.
    Hofer, S.
    XXII ISPRS CONGRESS, TECHNICAL COMMISSION I, 2012, 39-B1 : 267 - 272
  • [22] In-flight Camera Platform Geometric Calibration of the Aerial Multi-Head Camera System
    Lee, Young-Jin
    Yilmaz, Alper
    Mendoza-Schrock, Olga
    PROCEEDINGS OF THE IEEE 2010 NATIONAL AEROSPACE AND ELECTRONICS CONFERENCE (NAECON), 2010, : 136 - 139
  • [23] Geometric in-flight calibration of the stereoscopic line-CCD scanner MOMS-2P
    Kornus, W
    Lehner, M
    Schroeder, M
    ISPRS JOURNAL OF PHOTOGRAMMETRY AND REMOTE SENSING, 2000, 55 (01) : 59 - 71
  • [24] In-flight absolute radiometric calibration of MODIS using the irradiance-based method
    Wei, Wei
    Li, Xin
    Zhao, Chun-yan
    Qiu, Gang-gang
    Zheng, Xiao-bing
    HYPERSPECTRAL REMOTE SENSING APPLICATIONS AND ENVIRONMENTAL MONITORING AND SAFETY TESTING TECHNOLOGY, 2016, 10156
  • [25] New method of in-flight absolute calibration for thermal infrared channals of satellite sensors
    Tong, JJ
    Qiu, KM
    Li, XW
    JOURNAL OF INFRARED AND MILLIMETER WAVES, 2005, 24 (04) : 277 - 280
  • [26] Method of in-flight wavelength calibration for wide band hyper-spectral imager
    Wang Y.
    Shi E.
    Wang H.
    Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2019, 48 (03):
  • [27] Soho Cds–nis in-flight intensity calibration using a plasma diagnostic method
    E. Landi
    M. Landini
    C. D. Pike
    H. E. Mason
    Solar Physics, 1997, 175 : 553 - 570
  • [28] A new method for in-flight intensity calibration of high-resolution EUV and FUV spectrometers
    Feldman, U
    Landi, E
    Doschek, GA
    Mariska, JT
    ASTRONOMY & ASTROPHYSICS, 2005, 441 (03): : 1211 - 1215
  • [29] SOHO CDS-NIS in-flight intensity calibration using a plasma diagnostic method
    Landi, E
    Landini, M
    Pike, CD
    Mason, HE
    SOLAR PHYSICS, 1997, 175 (02) : 553 - 570
  • [30] Uncertainty Evaluation of an In-Flight Absolute Radiometric Calibration Using a Statistical Monte Carlo Method
    Chen, Wei
    Zhao, Haimeng
    Li, Zhanqing
    Jing, Xin
    Yan, Lei
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2015, 53 (05): : 2925 - 2934