Clinical and in vitro application of robotic computer-assisted implant surgery: a scoping review

被引:1
|
作者
Zhou, W. K. [1 ,2 ]
Wang, J. J. [1 ,2 ]
Jiang, Y. H. [1 ,2 ]
Yang, L. [1 ,2 ]
Luo, Y. L. [1 ,2 ,3 ]
Man, Y. [1 ,2 ,3 ]
Wang, J. [1 ,2 ,3 ]
机构
[1] Sichuan Univ, West China Hosp Stomatol, State Key Lab Oral Dis, 3rd Sect,Renmin Nan Rd, Chengdu 610041, Sichuan, Peoples R China
[2] Sichuan Univ, West China Hosp Stomatol, Natl Clin Res Ctr Oral Dis, 3rd Sect,Renmin Nan Rd, Chengdu 610041, Sichuan, Peoples R China
[3] Sichuan Univ, West China Hosp Stomatol, Dept Oral Implantol, Chengdu, Sichuan, Peoples R China
关键词
Dental implants; Computer-assisted surgery; Robotic surgical procedures; Intraoperative complications; Postoperative complications; Operative time; PLACEMENT;
D O I
10.1016/j.ijom.2024.09.006
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
In recent years, the emergence and application of robotic computer- assisted implant surgery (r-CAIS) has resulted in a revolutionary shift in conventional implant diagnosis and treatment. This scoping review was performed to verify the null hypothesis that r-CAIS has a relatively high accuracy of within 1 mm, with relatively few complications and a short operative time. This review was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta- Analyses Extension for Scoping Reviews (PRISMA-ScR). From the 3355 publications identified in the PubMed, Scopus, Web of Science, and Google Scholar databases, 28 were finally included after a comprehensive review and analysis. The null hypothesis is partly accepted, as r-CAIS has a relatively high accuracy (coronal and apical deviation within 1 mm), and no significant adverse events or complications have been reported to date, although additional confirmatory studies are needed. However, there is insufficient evidence for a shorter surgical time, and further clinical research on this topic is required.
引用
收藏
页码:74 / 81
页数:8
相关论文
共 50 条
  • [31] Computer-assisted surgery
    Feussner, H.
    COLOPROCTOLOGY, 2018, 40 (02) : 100 - 101
  • [32] Does implant drill design influence the accuracy of dental implant placement using static computer-assisted implant surgery? An in vitro study
    Anna Takács
    Gyula Marada
    Kinga Turzó
    Ákos Nagy
    Orsolya Németh
    Eitan Mijiritsky
    Márton Kivovics
    Attila Mühl
    BMC Oral Health, 23
  • [33] Does implant drill design influence the accuracy of dental implant placement using static computer-assisted implant surgery? An in vitro study
    Takacs, Anna
    Marada, Gyula
    Turzo, Kinga
    Nagy, Akos
    Nemeth, Orsolya
    Mijiritsky, Eitan
    Kivovics, Marton
    Muhl, Attila
    BMC ORAL HEALTH, 2023, 23 (01)
  • [34] Computer-assisted bone augmentation, implant planning and placement: An in vitro investigation
    Unger, S.
    Benic, G. I.
    Ender, A.
    Pasic, P.
    Hammerle, C. H. F.
    Stadlinger, B.
    CLINICAL ORAL IMPLANTS RESEARCH, 2023, 34 (07) : 719 - 726
  • [35] Accuracy Comparison between Robot-Assisted Dental Implant Placement and Static/Dynamic Computer-Assisted Implant Surgery: A Systematic Review and Meta-Analysis of In Vitro Studies
    Jain, Saurabh
    Sayed, Mohammed E.
    Ibraheem, Wael I.
    Ageeli, Abrar A.
    Gandhi, Sumir
    Jokhadar, Hossam F.
    Alresayes, Saad Saleh
    Alqarni, Hatem
    Alshehri, Abdullah Hasan
    Huthan, Halah Mohammed
    Alami, Atheer
    Al Wadei, Mohammed Hussain Dafer
    Aljabri, Yahya
    MEDICINA-LITHUANIA, 2024, 60 (01):
  • [36] Guided and computer-assisted implant surgery and prosthetic: The continuous digital workflow
    Pascual, D.
    Vaysse, J.
    REVUE DE STOMATOLOGIE DE CHIRURGIE MAXILLO-FACIALE ET DE CHIRURGIE ORALE, 2016, 117 (01) : 28 - 35
  • [37] Papilla Formation in Response to Computer-Assisted Implant Surgery and Immediate Restoration
    Schnitman, Paul A.
    Hayashi, Chie
    JOURNAL OF ORAL IMPLANTOLOGY, 2015, 41 (04) : 459 - 466
  • [38] Influence of template design on the accuracy of static computer-assisted implant surgery
    Chung, Jinmook
    Park, Junghyun
    Son, Hyeonseong
    Hong, Seoung-Jin
    Pae, Ahran
    JOURNAL OF ADVANCED PROSTHODONTICS, 2025, 17 (01): : 22 - 35
  • [39] A methodological tool for computer-assisted surgery interface design: Its application to computer-assisted pericardial puncture
    Dubois, E
    Nigay, L
    Troccaz, J
    Carrat, L
    Chavanon, O
    MEDICINE MEETS VIRTUAL REALITY 2001: OUTER SPACE, INNER SPACE, VIRTUAL SPACE, 2001, 81 : 136 - 138
  • [40] Accuracy of the Yakebot dental implant robotic system versus fully guided static computer-assisted implant surgery template in edentulous jaw implantation: A preliminary clinical study
    Wang, Wenxue
    Xu, Hao
    Mei, Dongmei
    Zhou, Chen
    Li, Xiaojing
    Han, Ze'yu
    Zhou, Xiaobin
    Li, Xin
    Zhao, Baodong
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2024, 26 (02) : 309 - 316