Sensitive Determination of Bisphenol A In Urine Using Automated Solid-Phase Extraction Followed by LC-MS/MS Analysis: Application to a Human Biomonitoring Study in Brazil

被引:0
|
作者
de Souza, Camila F. [1 ,2 ]
Peteffi, Giovana P. [1 ,2 ]
Loredo, Cole D. [1 ,3 ]
Bastiani, Marcos F. [1 ,2 ]
Bondan, Amanda P. [1 ,3 ]
Grassi, Giovanna S. [1 ]
Ferrareze, Carolina W. [1 ,3 ]
Winter, Paola [1 ]
Hahn, Roberta Z. [1 ,2 ]
Antunes, Marina, V [1 ,3 ]
Linden, Rafael [1 ,2 ]
机构
[1] Univ Feevale, Lab Toxicol Analit, BR-93352000 Novo Hamburgo, RS, Brazil
[2] Univ Feevale, Programa Posgrad Qualidade Ambiental, BR-93352000 Novo Hamburgo, RS, Brazil
[3] Univ Feevale, Programa Posgrad Toxicol & Anal Toxicol, BR-93352000 Novo Hamburgo, RS, Brazil
关键词
urine; hair; bisphenol A; biomonitoring; UHPLC-MS/MS; LIQUID-LIQUID MICROEXTRACTION; MASS-SPECTROMETRY METHOD; HUMAN EXPOSURE; BPA; QUANTIFICATION; BIOMARKER; PHENOLS; ANALOGS; HEALTH; WATER;
D O I
10.21577/0103-5053.20240226
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Bisphenol A (BPA), an endocrine disruptor present mostly in polycarbonate plastics and epoxy resins, can migrate into food and beverages, resulting in human exposure. This study aimed to develop and validate an improved liquid chromatography-tandem mass spectroscopy (LC-MS/MS) method for measuring BPA levels in urine, applying this method for BPA exposure evaluation in a Brazilian cohort, along with BPA hair levels. Samples from 100 volunteers were collected. Urine samples were extracted using an automated solid-phase extraction procedure. The assay had a 6.5-min run time, a linear range of 0.10-25 ng mL-1, precision of 3.8-18.1%, and accuracy of 96.6-103.4%. BPA was detected in all tested urine samples (median 0.86 ng mL-1). In hair, 47% of samples had detectable BPA concentrations (median 4.8 ng g-1). No correlation was found between BPA levels in urine and hair. All levels were below the safety threshold, indicating minimal risk for the studied population, with higher urinary BPA linked to canned product consumption and higher hair levels to a healthier diet.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Determination of etoricoxib in human plasma using automated on-line solid-phase extraction coupled with LC-APCI/MS/MS
    Dalmora, Sergio Luiz
    Brum Junior, Liberato
    Ferretto, Ricardo Machado
    de Oliveira, Paulo Renato
    Barth, Thiago
    Sangoi, Maximiliano da Silva
    QUIMICA NOVA, 2008, 31 (03): : 574 - 578
  • [32] Optimization of a Multiresidue Analysis of 65 Pesticides in Surface Water Using Solid-Phase Extraction by LC-MS/MS
    Nakhjavan, Bahar
    Bland, Jason
    Khosravifard, Maryam
    MOLECULES, 2021, 26 (21):
  • [33] Analysis of Acidic Endogenous Phytohormones in Grapes by Using Online Solid-Phase Extraction Coupled with LC-MS/MS
    Yu, Jian-Na
    Meng, Qing-Yan
    Liu, Wen-Jie
    Lu, Ya-Ling
    Ren, Xiao-Lin
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2014, 52 (09) : 1145 - 1149
  • [34] Comparison of different solid-phase extraction materials for the determination of fluoroquinolones in chicken plasma by LC-MS/MS
    Janusch, Franziska
    Scherz, Gesine
    Mohring, Siegrun A. I.
    Stahl, Jessica
    Hamscher, Gerd
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 951 : 149 - 156
  • [35] Rapid and Sensitive LC-MS/MS Assay for Quantitation of Letrozole Using Solid-Phase Extraction from Human Blood Plasma and Its Application to Pharmacokinetic Studies
    A. I. Platova
    I. I. Miroshnichenko
    S. N. Ptitsina
    N. I. Yurchenko
    Pharmaceutical Chemistry Journal, 2014, 48 : 292 - 297
  • [36] Simultaneous Determination of Twelve Sweeteners and Nine Preservatives in Foods by Solid-Phase Extraction and LC-MS/MS
    Tsuruda, Sayuri
    Sakamoto, Tomonori
    Akaki, Kouichi
    FOOD HYGIENE AND SAFETY SCIENCE, 2013, 54 (03): : 204 - 212
  • [37] Determination of atorvastatin and metabolites in human plasma with solid-phase extraction followed by LC-tandem MS
    Hermann, M
    Christensen, H
    Reubsaet, JLE
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 382 (05) : 1242 - 1249
  • [38] Determination of nitrofuran metabolites in honey using a new derivatization reagent, magnetic solid-phase extraction and LC-MS/MS
    Melekhin, Artem O.
    Tolmacheva, Veronika V.
    Shubina, Elena G.
    Dmitrienko, Stanislava G.
    Apyari, Vladimir V.
    Grudev, Artyom, I
    TALANTA, 2021, 230
  • [39] Sensitive determination of gentamicin in plasma using ion-exchange solid-phase extraction followed by UHPLC-MS/MS analysis
    dos Santos, Ana Laura Anibaletto
    da Silva, Anne Caroline Cezimbra
    Lizot, Lilian de Lima Feltraco
    Schneider, Anelise
    Hahn, Roberta Zilles
    Meireles, Yasmin Fazenda
    Pagnussat, Lidiane Riva
    Nonnenmacher, Julia Livia
    Hahn, Siomara Regina
    Linden, Rafael
    PRACTICAL LABORATORY MEDICINE, 2021, 26
  • [40] Determination of trace hydroxyl polycyclic aromatic hydrocarbons in urine using graphene oxide incorporated monolith solid-phase extraction coupled with LC-MS/MS
    Li, Zi-Ling
    Li, Na
    Du, Li
    Wang, Ya-Hui
    Fang, Bo
    Wang, Man-Man
    Wang, Qian
    JOURNAL OF SEPARATION SCIENCE, 2019, 42 (20) : 3234 - 3242