Acetabular Augments Used in Revision Hip Arthroplasty: Minimum 10-year Follow-Up of Implant Survivorships, Functional Scores, and Radiographic Outcomes

被引:0
|
作者
Braunstein, Doris [1 ]
Greenberg, Arieh [1 ,2 ]
Chaudhry, Faran [1 ,3 ]
Daud, Anser [1 ,2 ]
Sa, Oleg A. [1 ,2 ]
Gross, Allan E. [1 ,2 ]
Kuzyk, Paul R. [1 ,2 ]
机构
[1] Mt Sinai Hosp, Dept Orthopaed Surg, Toronto, ON, Canada
[2] Univ Toronto, Dept Surg, Div Orthopaed Surg, Toronto, ON, Canada
[3] Univ Toronto, Temerty Fac Med, Toronto, ON, Canada
来源
JOURNAL OF ARTHROPLASTY | 2025年 / 40卷 / 03期
关键词
revision total hip arthroplasty; acetabular defect; acetabular augment; hip; flying buttress augment; dome augment; TRABECULAR METAL AUGMENTS; POROUS TANTALUM AUGMENTS; PELVIC DISCONTINUITY; BONE LOSS; DEFECTS; RECONSTRUCTION; COMPONENT; CAGE; ALLOGRAFT; RING;
D O I
10.1016/j.arth.2024.09.004
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Acetabular bone loss is a major challenge in the setting of revision total hip arthroplasty (THA). Porous tantalum augments have emerged as a viable solution to acetabular bone loss in revision THA. The purpose of this study was to evaluate the survivorship, clinical, and radiological outcomes of these implants. Methods: We identified 104 augment implants from our retrospective chart review of revision THA from June 2003 to July 2013. Of these patients, 75 (72.1%) were women, the mean age at surgery was 66 years (range, 27 to 87), and the mean follow-up was 13.2 years (range, 0.25 to 18.2). Kaplan-Meier survival analysis was performed, with failure defined as revision for aseptic loosening of the acetabular reconstruction. Results: There was significant improvement in the Harris Hip Score from 40.0 to 77.3 (P < 0.001) and the Oxford Hip Score from 14.9 to 36.3 (P < 0.001). Survivorship for failure due to aseptic loosening was 98.8% (95% CI [confidence interval] 96.4 to 100) at 24 months with 60 hips at risk, and 90.4% (95% CI 83.0 to 97.8) at 60 and 120 months with 38 and 18 hips at risk, respectively. The overall number of complications was 34 (32.7%). Of these complications, 21 (20.2%) required repeat revision surgery. The revision rate due to aseptic loosening of the augment, infection, dislocation, aseptic loosening of the femoral component, reconstruction failure, and heterotopic ossification was seven (6.7%), five (4.8%), four (3.8%), two (1.9%), two (1.9%), and one (0.96%), respectively. Conclusions: Treatment of acetabular defects during revision THA using porous tantalum augments provides acceptable implant survivorship and favorable clinical outcomes at mid-term (5 to 10 years) and long-term (> 10 years) follow-up. (c) 2024 The Authors. Published by Elsevier Inc. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:751 / 757
页数:7
相关论文
共 50 条
  • [41] Revision Total Hip Arthroplasty Utilizing an Acetabular Reinforcement Ring with a Metal Augment: A Minimum Eight-Year Follow-Up Study
    Kim, Han Soul
    Kim, Ji Wan
    Chang, Jae Suk
    Kim, Chul-Ho
    MEDICINA-LITHUANIA, 2023, 59 (06):
  • [42] Radiographic Progression of Osteoarthritis after Rotational Acetabular Osteotomy: Minimum 10-Year Follow-up Outcome According to the Tonnis Grade
    Min, Byung-Woo
    Kang, Chang Soo
    Lee, Kyung-Jae
    Bae, Ki-Cheor
    Cho, Chul-Hyun
    Choi, Jung-Hoon
    Sohn, Hyuk-Joon
    Sin, Hong-Kwan
    CLINICS IN ORTHOPEDIC SURGERY, 2018, 10 (03) : 299 - 306
  • [43] Minimal Incision Total Hip Arthroplasty A Concise Follow-up Report on Functional and Radiographic Outcomes at 10 Years
    Stevenson, Ciara
    Ogonda, Luke
    Blaney, Janine
    Dennison, Janice
    O'Brien, Seamus
    Beverland, David
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2017, 99 (20): : 1715 - 1720
  • [44] Acetabular microfracture in hip arthroscopy: clinical outcomes with minimum 5-year follow-up
    Domb, Benjamin G.
    Rybalko, Danil
    Mu, Brian
    Litrenta, Jody
    Chen, Austin W.
    Perets, Itay
    HIP INTERNATIONAL, 2018, 28 (06) : 649 - 656
  • [45] FUNCTIONAL-EVALUATION OF TOTAL HIP-ARTHROPLASTY WITH 5-YEAR TO 10-YEAR FOLLOW-UP EVALUATION
    PERRIN, T
    DORR, LD
    PERRY, J
    GRONLEY, J
    HULL, DB
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1985, (195) : 252 - 260
  • [46] Unicompartmental knee arthroplasty: 10-year follow-up
    Bistolfi, A.
    Crova, M.
    Deledda, D.
    Paonessa, M.
    Cimino, A.
    Ravera, L.
    Massazza, G.
    MINERVA ORTOPEDICA E TRAUMATOLOGICA, 2012, 63 (03) : 155 - 161
  • [47] Total Wrist Arthroplasty: A 10-Year Follow-Up
    Fischer, Per
    Sagerfors, Marcus
    Jakobsson, Hugo
    Pettersson, Kurt
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2020, 45 (08): : 780.e1 - 780.e10
  • [48] Revision Total Hip Arthroplasty for Large Medial Defects With Witch's Hat-Shaped Structural Allografts - Minimum 10-Year Follow-Up
    Peng, Kuo-Ti
    Hsu, Wei-Hsiu
    Shih, Hsin-Nung
    Chen, Chun-Chieh
    Yeh, Jih-Hsi
    JOURNAL OF ARTHROPLASTY, 2014, 29 (02): : 428 - 431
  • [49] Use of constrained acetabular components for hip instability: An average 10-year follow-up study
    Bremner, BRB
    Goetz, DD
    Callaghan, JJ
    Capello, WN
    Johnston, RC
    JOURNAL OF ARTHROPLASTY, 2003, 18 (07): : 131 - 137
  • [50] 10-YEAR FOLLOW-UP OF MULLER HIP REPLACEMENTS
    REIKERAS, O