Fluorescent biosensor for ultra-stability detection of Pax-5a based on a double cascade amplification strategy

被引:0
|
作者
Liu, Chang [1 ]
Zhang, Xinyi [1 ]
Xu, Jun [1 ]
Gao, Min [1 ]
Wang, Suqin [1 ]
Li, Hongbo [1 ]
机构
[1] Jiangxi Normal Univ, Coll Chem & Mat, Key Lab Energy Catalysis & Convers Nanchang, Nanchang 330022, Peoples R China
基金
中国国家自然科学基金;
关键词
Acute lymphoblastic leukemia; Fluorescent biosensor; Entropy-driven toehold-mediated strand; displacement; Double cascade amplification; Ultra-stability; DISPLACEMENT AMPLIFICATION; DNA; ISOFORMS;
D O I
10.1016/j.saa.2024.125632
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
The development of B-lymphoblastic leukemia is tightly associated with aberrant expression of Pax-5a. This work presented a novel dual signal amplification strategy-based Pax-5a detection method by combining the rolling circle amplification reaction (RCA) and the Entropy-driven toehold-mediated strand displacement (ETSD). Particularly noteworthy is the employed ETSD, which effectively improves the rate and stability of the reaction due to its unique entropy-driven principle. The uniqueness of this method is the combination of two amplification techniques, each utilizing its own strengths to achieve our intended purpose. This sensing method has been effectively used to determine the Pax-5a gene which with a reliable linear correlation for detection within a range and achieving a detection limit of 3.34 pM, calculated using the formula (3 sigma/S). Furthermore, even in 1 % of human serum samples, the biosensor can identify the target gene with exceptional sensitivity. The recovery rates fall within the range of 96.68-101.76 %, with a relative standard deviation (RSD) of 5.47 %. The method has a strong specificity based on sequence-specific hybridization of nucleic acids, thereby effectively preventing potential false-positive results. This fluorescent biosensor has a high detection capability for Pax-5a, and offers stable results. It provides a new way for early clinical diagnosis of acute lymphoblastic leukemia.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] A new photoelectrochemical biosensor for ultrasensitive determination of nucleic acids based on a three-stage cascade signal amplification strategy
    Xiong, Erhu
    Yan, Xiaoxia
    Zhang, Xiaohua
    Li, Yanmei
    Yang, Ruiying
    Meng, Leixia
    Chen, Jinhua
    ANALYST, 2018, 143 (12) : 2799 - 2806
  • [32] Sensitive Detection of Proteins Using Assembled Cascade Fluorescent DNA Nanotags Based on Rolling Circle Amplification
    Xue, Qingwang
    Wang, Zhenguang
    Wang, Lei
    Jiang, Wei
    BIOCONJUGATE CHEMISTRY, 2012, 23 (04) : 734 - 739
  • [33] Human serum biomarker detection based on a cascade signal amplification strategy by a DNA molecule machine
    Liu, Jing
    Xin, Xiaoyan
    Zhou, Hong
    Zhang, Shusheng
    CHEMICAL COMMUNICATIONS, 2015, 51 (54) : 10843 - 10846
  • [34] Label-free electrochemical aptasensor for adenosine detection based on cascade signal amplification strategy
    Shen, Jing
    Wang, Hongyang
    Li, Chunxiang
    Zhao, Yanyan
    Yu, Xijuan
    Luo, Xiliang
    BIOSENSORS & BIOELECTRONICS, 2017, 90 : 356 - 362
  • [35] A novel electrochemical biosensor for ultrasensitive detection of serum total bile acids based on enzymatic reaction combined with the double oxidation circular amplification strategy
    Tian, Gang
    Ding, Min
    Xu, Biao
    He, Yifan
    Lyu, Wenjing
    Jin, Mingchao
    Zhang, Xiaoqing
    BIOSENSORS & BIOELECTRONICS, 2018, 118 : 31 - 35
  • [36] Electrochemical biosensor for detection of ampicillin in milk based on Au5Pt and DNA cycle dual-signal amplification strategy
    Li, Mingyao
    Li, Ruiyi
    Li, Zaijun
    MICROCHIMICA ACTA, 2025, 192 (01)
  • [37] A novel fluorescent aptasensor for the detection of theophylline based on cryonase-driven signal amplification strategy
    Feng, Tingting
    Kang, Zhechen
    Yan, Shuzhu
    Huang, Yu
    Liu, Rui
    LUMINESCENCE, 2024, 39 (02)
  • [38] A fluorescent amplification strategy for high-sensitive detection of 17 β-estradiol based on EXPAR and HCR
    Wang, Yu
    Zhao, Xudong
    Zhang, Man
    Sun, Xuan
    Bai, Jialei
    Peng, Yuan
    Li, Shuang
    Han, Dianpeng
    Ren, Shuyue
    Wang, Jiang
    Han, Tie
    Gao, Yifei
    Ning, Baoan
    Gao, Zhixian
    ANALYTICA CHIMICA ACTA, 2020, 1116 : 1 - 8
  • [39] A cascade amplification strategy based on rolling circle amplification and hydroxylamine amplified gold nanoparticles enables chemiluminescence detection of adenosine triphosphate
    Wang, Ping
    Zhang, Tonghuan
    Yang, Taoyi
    Jin, Nan
    Zhao, Yanjun
    Fan, Aiping
    ANALYST, 2014, 139 (15) : 3796 - 3803
  • [40] An ultrasensitive impedance biosensor for Salmonella detection based on rotating high gradient magnetic separation and cascade reaction signal amplification
    Huang, Fengchun
    Xue, Li
    Qi, Wuzhen
    Cai, Gaozhe
    Liu, Yuanjie
    Lin, Jianhan
    BIOSENSORS & BIOELECTRONICS, 2021, 176 (176):