Additively manufactured zirconia periodontal splint integrated prosthesis: A proof-of-concept

被引:0
|
作者
Wang, Ziyan [1 ,2 ]
Guo, Lvhua [1 ,2 ]
Deng, Ke [3 ]
Yu, Ting [1 ,2 ]
Li, Ping [1 ,2 ]
机构
[1] Guangzhou Med Univ, Sch & Hosp Stomatol, Guangdong Engn Res Ctr Oral Restorat & Reconstruct, Dept Prosthodont, Guangzhou, Peoples R China
[2] Guangzhou Med Univ, Guangzhou Key Lab Basic & Appl Res Oral Regenerat, Guangzhou, Peoples R China
[3] Univ Hong Kong, Div Periodontol & Implant Dent, Faulty Dent, Hong Kong, Peoples R China
基金
中国国家自然科学基金;
关键词
Additively manufacturing; Material jetting; 3D printing; Periodontal splint; Zirconia; Trueness; DENTAL CERAMICS; BOND STRENGTH; RESIN; TEETH;
D O I
10.1016/j.jdent.2025.105701
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To provide a digital workflow for designing custom zirconia periodontal splints using material jetting (MJ) technology to support and rehabilitate periodontally compromised anterior teeth. Methods: Initially, the maxillary and mandibular teeth were scanned using a Trios3 intraoral scanner (IOS). Subsequently, the periodontal splint was digitally designed using a computer-aided design software. Then, a zirconia periodontal splint was produced using MJ technology with a three-dimensional (3D) printer (Carmel 1400C). Additionally, the trueness of the periodontal splint was analyzed using 3D detection software (Geomagic Control X 2018). Finally, the periodontal splint was adhered using resin cement. Results: In terms of trueness, the intaglio surface and the prosthesis of the periodontal splint matched well, whereas the lingual surface showed some deviation areas. The trueness root mean square (RMS) value of the splint was 57.7 mu m and the deviation remained within +/- 200 mu m. For clinical treatment, the periodontal splint was precisely bonded and achieved the effect of supporting and rehabilitating periodontally compromised anterior teeth. After six months of treatment, the follow-up results showed that the splint remained intact, with no further absorption of the alveolar bone. Conclusions: Additively manufactured zirconia periodontal splints exhibit good trueness and aesthetics. Periodontal splints can achieve precise bonding and maintain long-term bonding stability, and can help stabilize loosened teeth and prevent further absorption by the alveolar bone. Clinical significance: This proof-of-concept outlines a digital workflow for designing zirconia periodontal splints using MJ technology to improve outcomes of periodontitis treatments. Moreover, the adhesive stability and efficacy of periodontitis treatment using the periodontal splint were preliminarily verified.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Additively Manufactured Compliant Hybrid Gas Thrust Bearing for Supercritical Carbon Dioxide Turbomachinery: Design and Proof of Concept Testing
    Ertas, Bugra
    JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2021, 143 (08):
  • [22] Proof-of-Concept of a Millimeter-Wave Integrated Heterogeneous Network for 5G Cellular
    Okasaka, Shozo
    Weiler, Richard J.
    Keusgen, Wilhelm
    Pudeyev, Andrey
    Maltsev, Alexander
    Karls, Ingolf
    Sakaguchi, Kei
    SENSORS, 2016, 16 (09)
  • [23] A Proof-of-Concept of an Integrated VR and AI Application to Develop Classroom Management Competencies in Teachers in Training
    Docter, Margreet W.
    de Vries, Tamara N. D.
    Nguyen, Huu Dat
    van Keulen, Hanno
    EDUCATION SCIENCES, 2024, 14 (05):
  • [24] Building the evidence base for integrated care planning: proof-of-concept analysis of a multi-sector integrated dataset in Estonia
    Poppe, Adriana
    Aavik-Maertmaa, Gerli
    Rebane, Ene
    Meyer, Ingo
    INTERNATIONAL JOURNAL OF INTEGRATED CARE, 2022, 22
  • [25] Surface Plasmon Coupled Directional Emission for Integrated Fluorescence-Raman Biodetection: A Proof-of-Concept Study
    Wang, Jin
    Zhai, Yan-Yun
    Pan, Xiao-Hui
    Xu, Lin-Tao
    Li, Zhao
    Cao, Shuo-Hui
    Li, Yao-Qun
    CHEMISTRYMETHODS, 2022, 2 (06):
  • [26] Combined and hybrid marker models for radiostereometry assessment of polyethylene liner motion in dual mobility hip prosthesis: a proof-of-concept study
    Jorgensen, Peter Bo
    Kaptein, Bart L.
    Soballe, Kjeld
    Jakobsen, Stig S.
    Stilling, Maiken
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2021, 5 (01)
  • [27] Combined and hybrid marker models for radiostereometry assessment of polyethylene liner motion in dual mobility hip prosthesis: a proof-of-concept study
    Peter Bo Jørgensen
    Bart L. Kaptein
    Kjeld Søballe
    Stig S. Jakobsen
    Maiken Stilling
    European Radiology Experimental, 5
  • [28] Real-time prediction of intradialytic relative blood volume: a proof-of-concept for integrated cloud computing infrastructure
    Sheetal Chaudhuri
    Hao Han
    Caitlin Monaghan
    John Larkin
    Peter Waguespack
    Brian Shulman
    Zuwen Kuang
    Srikanth Bellamkonda
    Jane Brzozowski
    Jeffrey Hymes
    Mike Black
    Peter Kotanko
    Jeroen P. Kooman
    Franklin W. Maddux
    Len Usvyat
    BMC Nephrology, 22
  • [29] Real-time prediction of intradialytic relative blood volume: a proof-of-concept for integrated cloud computing infrastructure
    Chaudhuri, Sheetal
    Han, Hao
    Monaghan, Caitlin
    Larkin, John
    Waguespack, Peter
    Shulman, Brian
    Kuang, Zuwen
    Bellamkonda, Srikanth
    Brzozowski, Jane
    Hymes, Jeffrey
    Black, Mike
    Kotanko, Peter
    Kooman, Jeroen P.
    Maddux, Franklin W.
    Usvyat, Len
    BMC NEPHROLOGY, 2021, 22 (01)
  • [30] Hydrogen production with integrated CO2 capture in a novel gas switching reforming reactor: Proof-of-concept
    Wassie, Solomon A.
    Gallucci, Fausto
    Zaabout, Abdelghafour
    Cloete, Schalk
    Amini, Shahriar
    Annaland, Martin van Sint
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2017, 42 (21) : 14367 - 14379