Emulating the Delivery of Sawtooth Proton Arc Therapy Plans on a Cyclotron-Based Proton Beam Therapy System

被引:0
|
作者
Burford-Eyre, Samuel [1 ,2 ]
Aitkenhead, Adam [3 ,4 ]
Aylward, Jack D. [1 ,2 ,3 ,5 ]
Henthorn, Nicholas T. [3 ,4 ]
Ingram, Samuel P. [3 ,4 ]
Mackay, Ranald [3 ,4 ]
Manger, Samuel [3 ,4 ]
Merchant, Michael J. [4 ]
Sitch, Peter [3 ,4 ]
Warmenhoven, John-William [3 ,4 ]
Appleby, Robert B. [1 ,2 ]
机构
[1] Univ Manchester, Fac Sci & Engn, Sch Nat Sci, Dept Phys & Astron, Manchester M13 9PL, England
[2] Univ Manchester, Cockcroft Inst, Fac Sci & Engn, Sch Nat Sci, Manchester M13 9PL, England
[3] Christie NHS Fdn Trust, Christie Med Phys & Engn, Manchester M20 4BX, England
[4] Univ Manchester, Fac Biol Med & Heath, Div Canc Sci, Manchester M13 9PL, England
[5] Univ West England, Sch Appl Sci, Bristol BS16 1QY, England
基金
英国工程与自然科学研究理事会; 英国科学技术设施理事会; 欧盟地平线“2020”;
关键词
proton arc therapy; intensity modulated proton therapy; delivery; energy layer switching; gantry motion; sawtooth arc; SPARC THERAPY; DOSE CALCULATION; EFFICIENT; IMPROVE; ROBUST;
D O I
10.3390/cancers16193315
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Simple Summary The overall delivery time of proton arc therapy (PAT) plans on current clinical systems must be evaluated due to high upward energy layer switching times (ELSTs) in order to identify clinically suitable methods of PAT planning and delivery. We present the application of an emulator for modelling the delivery of 'sawtooth' PAT plans on an existing cyclotron-based system. We show that this method of PAT planning consistently requires a longer delivery time than static intensity modulated proton therapy (IMPT) and that delivering PAT using a continuous gantry rotation remains the optimum delivery method on such systems. This analysis shows that the delivery of PAT plans generated using the simplified sawtooth PAT planning approach may be clinically infeasible without further developments to the existing clinical technologies.Abstract Purpose: To evaluate and compare the deliverability of 'sawtooth' proton arc therapy (PAT) plans relative to static intensity modulated proton therapy (IMPT) at a cyclotron-based clinical facility. Methods: The delivery of single and dual arc Sawtooth PAT plans for an abdominal CT phantom and multiple clinical cases of brain, head and neck (H&N) and base of skull (BoS) targets was emulated under the step-and-shoot and continuous PAT delivery regimes and compared to that of a corresponding static IMPT plan. Results: Continuous PAT delivery increased the time associated with beam delivery and gantry movement in single/dual PAT plans by 4.86/7.34 min (brain), 7.51/12.40 min (BoS) and 6.59/10.57 min (H&N) on average relative to static IMPT. Step-and-shoot PAT increased this delivery time further by 4.79 min on average as the delivery was limited by gantry motion. Conclusions: The emulator can approximately model clinical sawtooth PAT delivery but requires experimental validation. No clear benefit was observed regarding beam-on time for sawtooth PAT relative to static IMPT.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Beam delivery sequencing for intensity modulated proton therapy
    Trofimov, A
    Bortfeld, T
    PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (10): : 1321 - 1331
  • [32] Gantry-Based Pencil Beam Scanning (PBS) Proton Therapy for Uveal Melanoma: IMPT vs. Proton Arc Therapy
    Qi, H.
    Hu, L.
    Huang, S.
    Lee, Y. P.
    Yu, F.
    Chen, Q.
    Yang, Y.
    Kang, M.
    Zhai, H.
    Shim, A.
    Park, P.
    Ding, X.
    Zhou, J.
    Simone, C. B., II
    Barker, C. A.
    Lin, H.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2024, 120 (02): : E780 - E781
  • [33] Application of a scattering foil to increase beam transmission for cyclotron based proton therapy facilities
    Maradia, Vivek
    Meer, David
    Weber, Damien Charles
    Lomax, Antony John
    Schippers, Jacobus Maarten
    Psoroulas, Serena
    FRONTIERS IN PHYSICS, 2022, 10
  • [34] Increase in Irradiation Beam Intensity by Using a Hybrid Target System in Cyclotron-Based Neutron Capture Therapy
    Takata, Takushi
    Tanaka, Hiroki
    Sakurai, Yoshinori
    Maruhashi, Akira
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2010, 47 (07) : 575 - 581
  • [35] Development of a standalone delivery sequence model for proton arc therapy
    Liu, Gang
    Zhao, Lewei
    Liu, Peilin
    Yan, Di
    Deraniyagala, Rohan
    Stevens, Craig
    Li, Xiaoqiang
    Ding, Xuanfeng
    MEDICAL PHYSICS, 2024, 51 (04) : 3067 - 3075
  • [36] Energy Thresholds in 180 Degree Arc Delivery Proton Therapy
    Sengbusch, E.
    Mackie, T.
    Perez-Andujar, A.
    DeLuca, P.
    MEDICAL PHYSICS, 2008, 35 (06) : 2846 - +
  • [37] Towards proton arc therapy
    Freeman, Tami
    PHYSICS WORLD, 2021, 34 (10) : 39 - 42
  • [38] Beam Profile Monitoring System for Proton Therapy
    Ho, Chili
    Chen, Augustine E.
    Dai, Shujhen
    Chu, Minglee
    Lin, Chih-Hsun
    Teng, Ping-Kun
    Wang, Chung-Hsiang
    Chao, Tsi-Chian
    Lee, Chung-Chi
    Tung, Chuang-Jong
    Duh, Ting-Shien
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 440 - 442
  • [39] Maximum proton kinetic energy and patient-generated neutron fluence considerations in proton beam arc delivery radiation therapy
    Sengbusch, E.
    Perez-Andujar, A.
    DeLuca, P. M., Jr.
    Mackie, T. R.
    MEDICAL PHYSICS, 2009, 36 (02) : 364 - 372
  • [40] Beam Dynamics Study in the C235 Cyclotron for Proton Therapy
    Karamysheva, G. A.
    Kostromin, S. A.
    PHYSICS OF PARTICLES AND NUCLEI LETTERS, 2009, 6 (01) : 84 - 90