Emulating the Delivery of Sawtooth Proton Arc Therapy Plans on a Cyclotron-Based Proton Beam Therapy System

被引:0
|
作者
Burford-Eyre, Samuel [1 ,2 ]
Aitkenhead, Adam [3 ,4 ]
Aylward, Jack D. [1 ,2 ,3 ,5 ]
Henthorn, Nicholas T. [3 ,4 ]
Ingram, Samuel P. [3 ,4 ]
Mackay, Ranald [3 ,4 ]
Manger, Samuel [3 ,4 ]
Merchant, Michael J. [4 ]
Sitch, Peter [3 ,4 ]
Warmenhoven, John-William [3 ,4 ]
Appleby, Robert B. [1 ,2 ]
机构
[1] Univ Manchester, Fac Sci & Engn, Sch Nat Sci, Dept Phys & Astron, Manchester M13 9PL, England
[2] Univ Manchester, Cockcroft Inst, Fac Sci & Engn, Sch Nat Sci, Manchester M13 9PL, England
[3] Christie NHS Fdn Trust, Christie Med Phys & Engn, Manchester M20 4BX, England
[4] Univ Manchester, Fac Biol Med & Heath, Div Canc Sci, Manchester M13 9PL, England
[5] Univ West England, Sch Appl Sci, Bristol BS16 1QY, England
基金
英国工程与自然科学研究理事会; 英国科学技术设施理事会; 欧盟地平线“2020”;
关键词
proton arc therapy; intensity modulated proton therapy; delivery; energy layer switching; gantry motion; sawtooth arc; SPARC THERAPY; DOSE CALCULATION; EFFICIENT; IMPROVE; ROBUST;
D O I
10.3390/cancers16193315
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Simple Summary The overall delivery time of proton arc therapy (PAT) plans on current clinical systems must be evaluated due to high upward energy layer switching times (ELSTs) in order to identify clinically suitable methods of PAT planning and delivery. We present the application of an emulator for modelling the delivery of 'sawtooth' PAT plans on an existing cyclotron-based system. We show that this method of PAT planning consistently requires a longer delivery time than static intensity modulated proton therapy (IMPT) and that delivering PAT using a continuous gantry rotation remains the optimum delivery method on such systems. This analysis shows that the delivery of PAT plans generated using the simplified sawtooth PAT planning approach may be clinically infeasible without further developments to the existing clinical technologies.Abstract Purpose: To evaluate and compare the deliverability of 'sawtooth' proton arc therapy (PAT) plans relative to static intensity modulated proton therapy (IMPT) at a cyclotron-based clinical facility. Methods: The delivery of single and dual arc Sawtooth PAT plans for an abdominal CT phantom and multiple clinical cases of brain, head and neck (H&N) and base of skull (BoS) targets was emulated under the step-and-shoot and continuous PAT delivery regimes and compared to that of a corresponding static IMPT plan. Results: Continuous PAT delivery increased the time associated with beam delivery and gantry movement in single/dual PAT plans by 4.86/7.34 min (brain), 7.51/12.40 min (BoS) and 6.59/10.57 min (H&N) on average relative to static IMPT. Step-and-shoot PAT increased this delivery time further by 4.79 min on average as the delivery was limited by gantry motion. Conclusions: The emulator can approximately model clinical sawtooth PAT delivery but requires experimental validation. No clear benefit was observed regarding beam-on time for sawtooth PAT relative to static IMPT.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] The Beam Commissioning of SC Cyclotron-Based Proton Therapy System With Fast Energy Selection and Precise Gantry
    Zhang, Tianjue
    Wang, Chuan
    Yin, Zhiguo
    Jia, Xianlu
    Wang, Yang
    Fu, Wei
    Liu, Jingyuan
    Jin, Zhaojun
    Zhou, Hongji
    Zhang, Suping
    Cai, Hongru
    Pan, Gaofeng
    Zhu, Xiaofeng
    Lin, Jun
    Zhao, Bohan
    Guo, Qiankun
    Liu, Chuanye
    Xiong, Rui
    He, Aolai
    Jiang, Tianyi
    Hu, Mingzhi
    Song, Qiqi
    Ding, Aoxuan
    Jiang, Shangmeng
    Liu, Ping
    Yang, Fangdi
    Huang, Xiesi
    Chu, Zhichao
    Xia, Xiaoxue
    Zhang, Zheyuan
    Qin, Ling
    Ma, Yongjun
    Cheng, Ziyi
    Xu, Zheng
    Le, Hao
    Zhang, Youwen
    Wang, Xi
    Liu, Zhan
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2025, 72 (03) : 438 - 445
  • [2] The Use of a Mini Ridge Filter with Cyclotron-Based Pencil Beam Scanning Proton Therapy
    O'grady, F.
    Janson, M.
    Rao, A.
    Chawla, A.
    Fan, J.
    Wang, P.
    MEDICAL PHYSICS, 2022, 49 (06) : E344 - E344
  • [3] New cyclotron-based proton therapy facility development to achieve conformal FLASH treatment plans
    Maradia, Vivek
    van de Water, Steven
    Weber, Damien Charles
    Lomax, Antony John
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S4636 - S4638
  • [4] The use of a mini-ridge filter with cyclotron-based pencil beam scanning proton therapy
    O'Grady, Fionnbarr
    Janson, Martin
    Rao, Avani D.
    Chawla, Ashish K.
    Stephenson, Lisa
    Fan, Jiajin
    Wang, Peng
    MEDICAL PHYSICS, 2023, 50 (04) : 1999 - 2008
  • [5] Increase of the transmission and emittance acceptance through a cyclotron-based proton therapy gantry
    Maradia, Vivek
    Giovannelli, Anna Chiara
    Meer, David
    Weber, Damien Charles
    Lomax, Antony John
    Schippers, Jacobus Maarten
    Psoroulas, Serena
    MEDICAL PHYSICS, 2022, 49 (04) : 2183 - 2192
  • [6] PROTON CYCLOTRON FOR BEAM THERAPY APPLICATION
    Alenitsky, Yu. G.
    Glazov, A. A.
    Karamysheva, G. A.
    Kostromin, S. A.
    Onischenko, L. M.
    Samsonov, E. V.
    Vorozhtsov, S. B.
    Vorozhtsov, A. S.
    Zaplatin, N. L.
    PROBLEMS OF ATOMIC SCIENCE AND TECHNOLOGY, 2008, (05): : 16 - 18
  • [7] Building a precise machine-specific time structure of the spot and energy delivery model for a cyclotron-based proton therapy system
    Zhao, Lewei
    Liu, Gang
    Zheng, Weili
    Shen, Jiajian
    Lee, Andrew
    Yan, Di
    Deraniyagala, Rohan
    Stevens, Craig
    Li, Xiaoqiang
    Tang, Shikui
    Ding, Xuanfeng
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (01):
  • [8] A new emittance selection system to maximize beam transmission for low-energy beams in cyclotron-based proton therapy facilities with gantry
    Maradia, Vivek
    Meer, David
    Weber, Damien Charles
    Lomax, Antony John
    Schippers, Jacobus Maarten
    Psoroulas, Serena
    MEDICAL PHYSICS, 2021, 48 (12) : 7613 - 7622
  • [9] A proton beam delivery system for conformal therapy and intensity modulated therapy
    Yu, QC
    Ke, XY
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2001, 25 (08): : 793 - 798
  • [10] Prototype development of the beam diagnostic system of a proton therapy facility based on a superconducting cyclotron
    Chen, Aote
    Chen, Qushan
    Liu, Xu
    Zhou, Chong
    Li, Dong
    Qin, Bin
    Kang, Xincai
    Xu, Zhiguo
    Li, Min
    Tang, Kai
    Mao, Ruishi
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 998