Diagnostic yield and safety of diagnostic techniques for pulmonary lesions: systematic review, meta-analysis and network meta-analysis

被引:2
|
作者
Balasubramanian, Prasanth [1 ]
Abia-Trujillo, David [2 ]
Barrios-Ruiz, Alana [2 ]
Garza-Salas, Ana [2 ]
Koratala, Anoop [2 ]
Chandra, Nikitha C. [2 ]
Lee-Mateus, Alejandra Yu [2 ]
Labarca, Gonzalo [3 ,4 ]
Fernandez-Bussy, Sebastian [2 ]
机构
[1] Mayo Clin, Dept Pulm & Crit Care Med, Jacksonville, FL USA
[2] Mayo Clin, Div Pulm Allergy & Sleep Med, Jacksonville, FL 32224 USA
[3] Harvard Med Sch, Beth Israel Deaconess Med Ctr, Div Sleep Med, Boston, MA USA
[4] Pontificia Univ Catolica Chile, Sch Med, Dept Resp Dis, Santiago, Chile
来源
EUROPEAN RESPIRATORY REVIEW | 2024年 / 33卷 / 173期
关键词
NEEDLE-BIOPSY; BRONCHOSCOPY; EXPERIENCE; NODULES;
D O I
10.1183/16000617.0046-2024
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background With recent advancements in bronchoscopic procedures, data on the best modality to sample peripheral pulmonary lesions (PPLs) is lacking, especially comparing bronchoscopy with computed tomography-guided transthoracic biopsy or needle aspiration (CT-TBNA). Methods We performed a meta-analysis, pairwise meta-analysis and network meta-analysis on studies reporting diagnostic yield and complications with the use of CT-TBNA, radial endobronchial ultrasound (rEBUS), virtual bronchoscopy (VB), electromagnetic navigation (EMN) or robot-assisted bronchoscopy (RAB) to sample PPLs. The primary outcome was diagnostic yield and the secondary outcome was complications. We estimated the relative risk ratios using a random-effects model and used the frequentist approach for the network meta-analysis. We performed extensive analysis to assess the heterogeneity including reporting bias, publication bias, subgroup and meta-regressional analysis. We assessed the quality of the studies using Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) and QUADAS-Comparative (QUADAS-C). Results We included 363 studies. The overall pooled diagnostic yield was 78.1%, the highest with CTTBNA (88.9%), followed by RAB (84.8%) and the least with rEBUS (72%). In the pairwise meta- analysis, only rEBUS showed inferiority to CT-TBNA. The network meta-analysis ranked CT-TBNA as likely the most effective approach followed by VB, EMN and RAB, while rEBUS was the least effective, with a low-GRADE certainty. CT-TBNA had the highest rate of complications. Conclusion Although CT-TBNA is the most effective approach to sample PPLs, RAB has a comparable diagnostic yield with a lesser complication rate. Further prospective studies are needed comparing CTTBNA and RAB.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Diagnostic accuracy of transthoracic echocardiography for pulmonary hypertension: a systematic review and meta-analysis
    Ni, Jin-Rong
    Yan, Pei-Jing
    Liu, Shi-Dong
    Hu, Yuan
    Yang, Ke-Hu
    Song, Bing
    Lei, Jun-Qiang
    BMJ OPEN, 2019, 9 (12):
  • [22] Diagnostic accuracy of lung ultrasound for pulmonary embolism: a systematic review and meta-analysis
    Squizzato, A.
    Rancan, E.
    Dentali, F.
    Bonzini, M.
    Guasti, L.
    Steidl, L.
    Mathis, G.
    Ageno, W.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2013, 11 (07) : 1269 - 1278
  • [23] Diagnostic accuracy of cardiopulmonary ultrasound for pulmonary embolism: A systematic review and meta-analysis
    Cao, Jingli
    Sun, Junjie
    Wang, Yuanyuan
    Wang, Lihong
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2022, 39 (02): : 185 - 193
  • [24] Diagnostic accuracy of lung ultrasound for pulmonary embolism: a systematic review and meta-analysis
    Squizzato, A.
    Rancan, E.
    Dentali, F.
    Bonzini, M.
    Guasti, L.
    Steidl, L.
    Mathis, G.
    Ageno, W.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2013, 11 : 601 - 601
  • [25] Diagnostic yield and safety of double balloon-assisted enteroscopy in the elderly: A systematic review and meta-analysis
    Chen, Y.
    Liu, G.
    Zhang, T.
    Yang, K.
    Yu, H.
    Tie, Y.
    Liang, J.
    Zhou, J.
    Gan, H.
    EUROPEAN GERIATRIC MEDICINE, 2017, 8 (04) : 354 - 359
  • [26] Diagnostic Yield and Safety of Endoscopic Ultrasound-guided Liver Biopsy: A Systematic Review and Meta-analysis
    Konjeti, Venkata Rajesh
    Rustagi, Tarun
    GASTROINTESTINAL ENDOSCOPY, 2016, 83 (05) : AB516 - AB516
  • [27] Comparative Analysis of Diagnostic Techniques for Melanoma Detection: A Systematic Review of Diagnostic Test Accuracy Studies and Meta-Analysis
    Blundo, Alessia
    Cignoni, Arianna
    Banfi, Tommaso
    Ciuti, Gastone
    FRONTIERS IN MEDICINE, 2021, 8
  • [28] The diagnostic performance of laboratory tests of neurosyphilis: a systematic review and network meta-analysis
    Ding, Duyu
    Gao, Junhua
    Zhang, Wei
    Xu, Dongmei
    EUROPEAN NEUROLOGY, 2023, 86 (06) : 418 - 429
  • [29] Comparison of diagnostic accuracy for diabetes diagnosis: A systematic review and network meta-analysis
    Duong, Khanh N. C.
    Tan, Chia Jie
    Rattanasiri, Sasivimol
    Thakkinstian, Ammarin
    Anothaisintawee, Thunyarat
    Chaiyakunapruk, Nathorn
    FRONTIERS IN MEDICINE, 2023, 10
  • [30] COMPARISON OF DIAGNOSTIC ACCURACY FOR DIABETIC DIAGNOSIS: A SYSTEMATIC REVIEW AND NETWORK META-ANALYSIS
    Duong, K.
    Tan, C. J.
    Rattanasiri, S.
    Thakkinstian, A.
    Anothaisintawee, T.
    Chaiyakunapruk, N.
    VALUE IN HEALTH, 2022, 25 (07) : S535 - S536