Experimental analysis of the exergetic performance of a solar air heater using separate liquid and solid sensible thermal storage media

被引:0
|
作者
Kumar, R. Ajith [1 ]
Baby, Rajesh [1 ,2 ]
Percy, Dani [3 ]
Kumar, S. Ajith [1 ]
机构
[1] Amrita Vishwa Vidyapeetham, Dept Mech Engn, Amritapuri, India
[2] St Josephs Coll Engn & Technol, Dept Mech Engn, Palai, India
[3] Prime Innovat, Dept Res & Dev, Ras Tanura, Saudi Arabia
关键词
TRANSFER FLUID; DRYERS;
D O I
10.1016/j.csite.2024.105709
中图分类号
O414.1 [热力学];
学科分类号
摘要
This experimental research examines the exergetic performance of a solar air heater utilizing liquid and solid sensible thermal storage (SES) mediums separately. The primary objective is to evaluate and compare the thermal and exergetic efficiencies of both storage mediums under varying operational conditions. Three models are studied: (i) SAHRR: A solar air heater without any sensible energy storage (SES) medium, (ii)SAHRRWPBS: A solar air heater incorporating pebbles as the SES medium, (iii)SAHRR-WTH55: A solar air heater incorporating Therminol 55 as the SES medium. The studies were carried out by employing an indoor solar simulator with different mass flow rates of 0.01, 0.02,0.03 and 0.06 kg/s with solar insolation varying between 600 and 1000 W/m2. By introducing SES mediums into the solar air heaters (SAHRR-WPBS.SAHRR-WTH55), the absorber plate's temperature was significantly lowered in comparison to the SAHRR, demonstrating the SES medium's thermal storage capabilities. For every mass flow rate taken into consideration, it was found that SAHRR-WPBS and SAHRR-WTH55 had more exergy efficiency than SAHRR. The outlet air temperature of SAHRR-WPBS and SAHRR-WTH55 stayed above the ambient temperature for 150 and 180 min, respectively, after operating for 2 h at 1000 W/m2 with a flow rate of 0.01 kg/s, following which the solar simulator was switched off. This proves that both SAHRRWPBS and SAHRR-WTH55 can extend functioning for period more than 2.5 h after sunset. The designed SAHRR-WPBS and SAHRR-WTH55 can generate hot air in the range between 45- 65 degrees C with minimal temperature variation over extended periods, making it suitable for producing high- quality dried products.
引用
收藏
页数:20
相关论文
共 50 条
  • [21] Investigation and optimization of design parameters for the thermal performance of a flat-plate solar air heater with sensible heat storage medium
    Selvaraj, Mariyappan
    Sadagopan, Palaniswamy
    Vijayan, Selvaraj
    DESALINATION AND WATER TREATMENT, 2023, 315 : 287 - 303
  • [22] EXPERIMENTAL ANALYSIS OF THERMAL PERFORMANCE OF A SOLAR AIR HEATER WITH A FLAT PLATE AND METALLIC FIBER
    Eleiwi, Muhammad Asmail
    Mohammed, Mohammed Fowzi
    Kamil, Kamil Talib
    JOURNAL OF ENGINEERING SCIENCE AND TECHNOLOGY, 2022, 17 (03): : 2049 - 2066
  • [23] Performance analysis and optimal charging time investigation of solar air heater with packed bed sensible heat storage device
    Turkakar, Goker
    SOLAR ENERGY, 2021, 224 : 718 - 729
  • [24] Experimental investigation of impact of the energy storage medium on the thermal performance of double pass solar air heater
    Kumar, Raj
    Gaurav
    Kumar, Sushil
    Afzal, Asif
    Manokar, A. Muthu
    Sharifpur, Mohsen
    Issakhov, Alibek
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2021, 48
  • [25] An experimental investigation of performance of a double pass solar air heater with foam aluminum thermal storage medium
    Baig, Wajahat
    Ali, Hafiz Muhammad
    CASE STUDIES IN THERMAL ENGINEERING, 2019, 14
  • [26] Unsteady analysis of a solar air heater with sensible heat storage using 2D finite difference approximation
    Phu, Nguyen Minh
    Nam, Lai Hoai
    Son, Nguyen Le Hong
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2023, 37 (11) : 6019 - 6028
  • [27] Unsteady analysis of a solar air heater with sensible heat storage using 2D finite difference approximation
    Nguyen Minh Phu
    Lai Hoai Nam
    Nguyen Le Hong Son
    Journal of Mechanical Science and Technology, 2023, 37 : 6019 - 6028
  • [28] Energy and exergetic analysis of a solar air heater for enhanced thermohydraulic performance with side wall treatment
    Hegde, Avinash K.
    Pai, Raghuvir
    Karanth, K. Vasudeva
    ENERGY, 2025, 315
  • [29] Design and performance analysis of a solar air heater with high heat storage
    Saxena, Abhishek
    Tirth, Vineet
    Srivastava, Ghanshyam
    Distributed Generation and Alternative Energy Journal, 2014, 29 (03): : 35 - 55
  • [30] CFD analysis for thermal performance augmentation of solar air heater using deflector ribs
    Venkatesh, R.
    Kumar, N.
    Madhwesh, N.
    Manjunath, M. S.
    JOURNAL OF MECHANICAL ENGINEERING AND SCIENCES, 2020, 14 (03) : 7282 - 7295