Mandible bone mineral density estimation using spectral panoramic X-ray imaging

被引:0
|
作者
Somerkivi, Villeseveri [1 ,2 ,3 ]
Sellerer, Thorsten [1 ,2 ]
Berthe, Daniel [1 ,2 ]
Haemisch, York [4 ]
Pantsar, Tuomas [4 ]
Lohman, Henrik [4 ]
Kaasalainen, Touko [5 ,6 ]
Pfeiffer, Franz [1 ,2 ,7 ,8 ]
机构
[1] Tech Univ Munich, Sch Nat Sci, Dept Phys, James Franck Str 1, D-85748 Garching, Germany
[2] Tech Univ Munich, Munich Inst Biomed Engn, Garching, Germany
[3] Planmeca Oy, Helsinki, Finland
[4] Varex Imaging Corp, Salt Lake City, UT USA
[5] Univ Helsinki, HUS Diag Ctr, Helsinki, Finland
[6] Helsinki Univ Hosp, Helsinki, Finland
[7] Tech Univ Munich, Dept Diag & Intervent Radiol, Klinikum Rechts Isar, Munich, Germany
[8] Tech Univ Munich, Inst Adv Study, Garching, Germany
关键词
Radiography; Dual-Energy Scanned Projection; X-Rays; Bone Density; OSTEOPOROSIS; SKELETAL;
D O I
10.5624/isd.20240231
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: This study demonstrated the feasibility of obtaining mandible bone mineral density (BMD) scores using spectral panoramic imaging. Materials and Methods: Areal BMD scores were measured from the body and angle of the mandible in 3 anthropomorphic head phantoms using a spectral panoramic system (Planmeca Promax Mid, Planmeca Oy, Helsinki, Finland) equipped with a DC-Vela detector (Varex Imaging Corporation, Salt Lake City, USA). These results were compared to synthetic panoramic images generated from dual-energy CT acquisitions. Reproducibility was evaluated by repeatedly scanning 1 phantom with minor patient positioning errors, and the linearity of the BMD scores was assessed using calcium inserts in a Gammex 472 phantom (Sun Nuclear, Melbourne, USA). Results: The experimental and synthetic panoramic images appeared visually similar. The mean synthetic score was 0.640 g/cm2, and the anthropomorphic phantoms produced a root mean squared error of 0.0292 g/cm2 with a correlation coefficient of 0.969. Typical patient positioning errors did not substantially increase the error, which measured 0.0296 g/cm2 and 0.0474 g/cm2 for the left and right sides, respectively. Linearity tests using the Gammex phantom yielded a correlation coefficient of 0.998 for BMD scores ranging from 0.03 to 2.7 g/cm2. Conclusion: The BMD data obtained from spectral panoramic imaging are consistent with both dual-energy CT and Gammex phantom measurements. Consequently, spectral panoramic imaging shows potential as a method for osteoporosis screening, leveraging the widespread use of panoramic imaging. (Imaging Sci Dent 20240231)
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Bone mineral density and bone mineral content estimation using low-cost x-ray detector
    Chuaychunu, N.
    Pititheerapab, Y.
    Chanwimalueang, T.
    Lertprasert, P.
    Pintavirooj, C.
    2007 6TH INTERNATIONAL CONFERENCE ON INFORMATION, COMMUNICATIONS & SIGNAL PROCESSING, VOLS 1-4, 2007, : 1001 - 1004
  • [2] Bone mineral density estimation using the filling factor of the radius X-ray image
    Lee, Sooyeul
    Jeong, Ji-Wook
    Lee, Jeong Won
    Yoo, Done-Sik
    Kim, Seunghwan
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 5533 - 5535
  • [3] Automatic segmentation of mandible in panoramic x-ray
    Abdi, Amir Hossein
    Kasaei, Shohreh
    Mehdizadeh, Mojdeh
    JOURNAL OF MEDICAL IMAGING, 2015, 2 (04)
  • [4] Study of mandible bone mineral density of Chinese adults by dual-energy X-ray absorptiometry
    Li, N.
    Jing, H.
    Li, J.
    Zhou, F.
    Bu, L.
    Yang, X.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2011, 40 (11) : 1275 - 1279
  • [5] NEW METHOD OF BONE MINERAL ESTIMATION USING A CONVENTIONAL X-RAY SET
    ARCHERHALL, JA
    CARPENTER, PB
    EDWARDS, JPN
    FRANCOIS, PE
    BRITISH JOURNAL OF RADIOLOGY, 1973, 46 (545): : 375 - 380
  • [6] Distal radius done mineral density estimation using the filling factor of trablecular bone in the x-ray image
    Lee, Sooyeul
    Jeong, Ji-Wook
    Lee, Jeong Won
    Yoo, Done-Sik
    Kim, Seunghwan
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 1197 - +
  • [7] Development of Bone Mineral Density and Bone Mineral Content Measurements System Using a Dual Energy X-ray
    Promworn, Y.
    Pintavirooj, C.
    5TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON 2012), 2012, : 102 - 102
  • [8] Development of Bone Mineral Density and Bone Mineral Content Measurements System Using a Dual Energy X-ray
    Promworn, Y.
    Pintavirooj, C.
    5TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON 2012), 2012,
  • [9] RELATIONSHIP BETWEEN BONE MINERAL DENSITY AND TRABECULAR BONE PATTERN IN POSTMENOPAUSAL BRAZILIAN WOMEN BY USING DUAL X-RAY ABSORPTIOMETRY AND DIGITAL PANORAMIC RADIOGRAPHS
    Alonso, M. B. C. C.
    Oliveira, M. L.
    Pedrosa, E. F. N. C.
    Ambrosano, G. M. B.
    Watanabe, P. C. A.
    Haiter-Neto, F.
    OSTEOPOROSIS INTERNATIONAL, 2012, 23 : S485 - S485
  • [10] The relationship between panoramic radiomorphometric indices of the mandible and calcaneus bone mineral density
    Jagelaviciene, Egle
    Kubilius, Ricardas
    Krasauskiene, Aurelija
    MEDICINA-LITHUANIA, 2010, 46 (02): : 95 - 103