A deep learning algorithm to generate synthetic computed tomography images for brain treatments from 0.35 T magnetic resonance imaging

被引:0
|
作者
Vellini, Luca [1 ]
Quaranta, Flaviovincenzo [1 ]
Menna, Sebastiano [1 ]
Pilloni, Elisa [1 ]
Catucci, Francesco [1 ]
Lenkowicz, Jacopo [2 ]
Votta, Claudio [2 ]
Aquilano, Michele [1 ]
D'Aviero, Andrea [3 ,4 ]
Iezzi, Martina [1 ]
Preziosi, Francesco [1 ]
Re, Alessia [1 ]
Boschetti, Althea [1 ]
Piccari, Danila [1 ]
Piras, Antonio [5 ]
Di Dio, Carmela [1 ]
Bombini, Alessandro [6 ,7 ]
Mattiucci, Gian Carlo [1 ,8 ]
Cusumano, Davide [1 ]
机构
[1] Mater Olbia Hosp, Olbia, Sassari, Italy
[2] Fdn Policlin Gemelli Agostino Gemelli IRCCS, Rome, Italy
[3] Gabriele Annunzio Univ Chieti, Dept Med Oral & Biotechnol Sci, Chieti, Italy
[4] SS Annunziata Chieti Hosp, Dept Radiat Oncol, Chieti, Italy
[5] UO Radioterapia Oncol, Bagheria, Palermo, Italy
[6] Ist Nazl Fis Nucleare INFN, Sesto Fiorentino, FI, Italy
[7] ICSC, Ctr Nazl Ric High Performance Comp Big Data & Quan, Casalecchio Di Reno, Italy
[8] Univ Cattolica Sacro Cuore, Rome, Italy
关键词
Artificial intelligence; Synthetic CT; MRI-only workflow; GAN; GUIDED RADIOTHERAPY; CT;
D O I
10.1016/j.phro.2025.100708
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and Purpose: The development of Magnetic Resonance Imaging (MRI)-only Radiotherapy (RT) represents a significant advancement in the field. This study introduces a Deep Learning (DL) algorithm designed to quickly generate synthetic CT (sCT) images from low-field MR images in the brain, an area not yet explored. Methods: Fifty-six patients were divided into training (32), validation (8), and test (16) groups. A conditional Generative Adversarial Network (cGAN) was trained on pre-processed axial paired images. sCTs were validated using mean absolute error (MAE) and mean error (ME) calculated within the patient body. Intensity Modulated Radiation Therapy (IMRT) plans were optimised on simulation MRI and calculated considering sCT and original CT as electron density (ED) map. Dose distributions using sCT and CT were compared using global gamma analysis at different tolerance criteria (2 %/2mm and 3 %/3mm) and evaluating the difference in estimating different Dose Volume Histogram (DVH) parameters for target and organs at risk (OARs). Results: The network generated sCTs of each single patient in less than two minutes (mean time = 103 +/- 41 s). For test patients, the MAE was 62.1 +/- 17.7 HU, and the ME was -7.3 +/- 13.4 HU. Dose parameters on sCTs were within 0.5 Gy of those on original CTs. Gamma passing rates 2 %/2mm, and 3 %/3mm criteria were 99.5 %+/- 0.5 %, and 99.7 %+/- 0.3 %, respectively. Conclusion: The proposed DL algorithm generates in less than 2 min accurate sCT images in the brain for online adaptive radiotherapy, potentially eliminating the need for CT simulation in MR-only workflows for brain treatments.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Evaluation of the Geometric and Dosimetric Accuracy of Synthetic Computed Tomography Images for Magnetic Resonance Imaging-only Stereotactic Radiosurgery
    Fatemi, Ali
    Kanakamedala, Madhava R.
    Yang, Claus Chunli
    Morris, Bart
    Duggar, William N.
    Vijayakumar, Srinivasan
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2019, 11 (04)
  • [32] Synthetic Computed Tomography from Magnetic Resonance in the Presence of Metal Implants
    Ushio, S.
    Pater, P.
    Fortier, V.
    Faucher, J.
    Levesque, I. R.
    MEDICAL PHYSICS, 2024, 51 (10) : 7737 - 7737
  • [33] Deep Learning-Enabled Brain Stroke Classification on Computed Tomography Images
    Tursynova, Azhar
    Omarov, Batyrkhan
    Tukenova, Natalya
    Salgozha, Indira
    Khaaval, Onergul
    Ramazanov, Rinat
    Ospanov, Bagdat
    CMC-COMPUTERS MATERIALS & CONTINUA, 2023, 75 (01): : 1431 - 1446
  • [34] Hydrocephalus classification in brain computed tomography medical images using deep learning
    Al Rub, Salsabeel Abu
    Alaiad, Ahmad
    Hmeidi, Ismail
    Quwaider, Muhannad
    Alzoubi, Omar
    SIMULATION MODELLING PRACTICE AND THEORY, 2023, 123
  • [35] Anatomical evaluation of deep-learning synthetic computed tomography images generated from male pelvis cone-beam computed tomography
    de Hond, Yvonne J. M.
    Kerckhaert, Camiel E. M.
    van Eijnatten, Maureen A. J. M.
    van Haaren, Paul M. A.
    Hurkmans, Coen W.
    Tijssen, Rob H. N.
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2023, 25
  • [36] Accuracy of Intraoperative Computed Tomography during Deep Brain Stimulation Procedures: Comparison with Postoperative Magnetic Resonance Imaging
    Bot, Maarten
    van den Munckhof, Pepijn
    Bakay, Roy
    Stebbins, Glenn
    Metman, Leo Verhagen
    STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2017, 95 (03) : 183 - 188
  • [37] Fusion of Magnetic Resonance Elastography Images With Computed Tomography and Magnetic Resonance Imaging Using the Human Visual System
    Alharbi, Fayez M.
    Besbes, Faten R.
    Almutairi, Basim S.
    Alotaibi, Abdullah T.
    Fatani, Faiq F.
    Besbes, Hatem R.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (09)
  • [38] Utility of fusion volumetric images from computed tomography and magnetic resonance imaging for localizing the mandibular canal
    Deepho, Chutamas
    Watanabe, Hiroshi
    Kotaki, Shinya
    Sakamoto, Junichiro
    Sumi, Yasunori
    Kurabayashi, Tohru
    DENTOMAXILLOFACIAL RADIOLOGY, 2017, 46 (03)
  • [39] Robustness and Generalizability of Deep Learning Synthetic Computed Tomography for Positron Emission Tomography/Magnetic Resonance Imaging -Based Radiation Therapy Planning of Patients With Head and Neck Cancer
    Olin, Anders B.
    Thomas, Christopher
    Hansen, Adam E.
    Rasmussen, Jacob H.
    Krokos, Georgios
    Urbano, Teresa Guerrero
    Michaelidou, Andriana
    Jakoby, Bjoern
    Ladefoged, Claes N.
    Berthelsen, Anne K.
    Hakansson, Katrin
    Vogelius, Ivan R.
    Specht, Lena
    Barrington, Sally F.
    Andersen, Flemming L.
    Fischer, Barbara M.
    ADVANCES IN RADIATION ONCOLOGY, 2021, 6 (06)
  • [40] The 'Mini Brain' Appearance of Plasmocytoma: Computed Tomography and Magnetic Resonance Imaging Findings
    Caliskan, Emine
    Savas, Recep
    MEANDROS MEDICAL AND DENTAL JOURNAL, 2015, 16 (02): : 80 - 82