The Effect of Insulin Degludec Versus Insulin Glargine U100 on Glucose Metrics Recorded During Continuous Glucose Monitoring in People With Type 1 Diabetes and Recurrent Nocturnal Severe Hypoglycemia

被引:0
|
作者
Brosen, Julie Maria Boggild [1 ,2 ]
Agesen, Rikke Mette [1 ,3 ]
Alibegovic, Amra Ciric [3 ,4 ]
Andersen, Henrik Ullits [2 ,4 ]
Beck-Nielsen, Henning [5 ,6 ]
Gustenhoff, Peter [7 ]
Hansen, Troels Krarup [8 ,9 ]
Hedetoft, Christoffer [10 ]
Jensen, Tonny Joran [2 ,11 ]
Juhl, Claus Bogh [6 ,12 ,13 ]
Stolberg, Charlotte Ron [6 ,12 ]
Lerche, Susanne Sogaard [14 ]
Norgaard, Kirsten [2 ,4 ,15 ]
Parving, Hans-Henrik [11 ]
Tarnow, Lise [16 ,17 ]
Thorsteinsson, Birger [1 ,2 ]
Pedersen-Bjergaard, Ulrik [1 ,2 ]
机构
[1] Copenhagen Univ Hosp, Nordsjaellands Hosp, Dept Endocrinol & Nephrol, Dyrehavevej 29, DK-3400 Hillerod, Denmark
[2] Univ Copenhagen, Fac Hlth & Med Sci, Dept Clin Med, Copenhagen, Denmark
[3] Novo Nordisk AS, Dept Med Sci, Soborg, Denmark
[4] Steno Diabet Ctr Copenhagen, Herlev, Denmark
[5] Odense Univ Hosp, Dept Endocrinol, Odense, Denmark
[6] Univ Southern Denmark, Fac Hlth & Sci, Dept Reg Hlth Res, Odense, Denmark
[7] Steno Diabet Ctr North, Aalborg, Denmark
[8] Aarhus Univ, Dept Clin Med, Aarhus, Denmark
[9] Steno Diabet Ctr Aarhus, Aarhus, Denmark
[10] Zealand Univ Hosp, Dept Internal Med, Koge, Denmark
[11] Copenhagen Univ Hosp, Dept Endocrinol, Rigshosp, Copenhagen, Denmark
[12] Univ Hosp Southwest Jutland, Dept Med, Esbjerg, Denmark
[13] Steno Diabet Ctr Odense, Odense, Denmark
[14] Lillebaelt Hosp, Dept Diabet & Hormonal Dis, Kolding, Denmark
[15] Copenhagen Univ Hosp, Hvidovre Hosp, Dept Endocrinol, Copenhagen, Denmark
[16] Steno Diabet Ctr Sjaelland, Holbaek, Denmark
[17] Copenhagen Univ Hosp, Nordsjaellands Hosp, Dept Clin Res, Hillerod, Denmark
来源
JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY | 2025年 / 19卷 / 02期
关键词
CGM; insulin analogs; time-above-range; time-below-range; time in range; type; 1; diabetes; GLYCEMIC CONTROL; BASAL INSULIN; VARIABILITY; ACCURACY; HBA(1C); RISK; CGM;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim: Comparing continuous glucose monitoring (CGM)-recorded metrics during treatment with insulin degludec (IDeg) versus insulin glargine U100 (IGlar-100) in people with type 1 diabetes (T1D) and recurrent nocturnal severe hypoglycemia. Materials and methods: This is a multicenter, two-year, randomized, crossover trial, including 149 adults with T1D and minimum one episode of nocturnal severe hypoglycemia within the last two years. Participants were randomized 1:1 to treatment with IDeg or IGlar-100 and given the option of six days of blinded CGM twice during each treatment. CGM traces were reviewed for the percentage of time-within-target glucose range (TIR), time-below-range (TBR), time-above-range (TAR), and coefficient of variation (CV). Results: Seventy-four participants were included in the analysis. Differences between treatments were greatest during the night (23:00-06:59). Treatment with IGlar-100 resulted in 54.0% vs 49.0% with IDeg TIR (70-180 mg/dL) (estimated treatment difference [ETD]: -4.6%, 95% confidence interval [CI]: -9.1, -0.0, P = .049). TBR was lower with IDeg at level 1 (54-69 mg/dL) (ETD: -1.7% [95% CI: -2.9, -0.5], P < .05) and level 2 (<54 mg/dL) (ETD: -1.3% [95% CI: -2.1, -0.5], P = .001). TAR was higher with IDeg compared with IGlar-100 at level 1 (181-250 mg/dL) (ETD: 4.0% [95% CI: 0.8, 7.3], P < .05) and level 2 (> 250 mg/dL) (ETD: 4.0% [95% CI: 0.8, 7.2], P < .05). The mean CV was lower with IDeg than that with IGlar-100 (ETD: -3.4% [95% CI: -5.6, -1.2], P < .05). Conclusion: For people with T1D suffering from recurrent nocturnal severe hypoglycemia, treatment with IDeg, compared with IGlar-100, results in a lower TBR and CV during the night at the expense of more TAR.
引用
收藏
页码:390 / 399
页数:10
相关论文
共 50 条
  • [21] Insulin degludec vs glargine U100 in people with type 1 diabetes: Does one size fit all?
    Hjejle, S.
    Brosen, J. M. B.
    Agesen, R. M.
    Thorsteinsson, B.
    Pedersen-Bjergaard, U.
    DIABETOLOGIA, 2023, 66 (SUPPL 1) : S395 - S396
  • [22] Duration of type 2 diabetes does not appear to moderate hypoglycaemia rate with insulin degludec versus insulin glargine U100
    Alexopoulos, Anastasia-Stefania
    Andersen, Andreas
    Donatsky, Anders Meller
    Gowda, Amoolya
    Buse, John B.
    DIABETES OBESITY & METABOLISM, 2021, 23 (08): : 1983 - 1988
  • [23] Insulin Degludec Has Lower Hypoglycemia Risk than Insulin Glargine U100 in Older People with Type 2 Diabetes (T2D)
    Heller, Simon R.
    Devries, J. Hans
    Wysham, Carol H.
    Hansen, Charlotte T.
    Hansen, Melissa V.
    Frier, Brian M.
    DIABETES, 2018, 67
  • [24] Insulin degludec versus insulin glargine U100 for patients with type 1 or type 2 diabetes in the US: a budget impact analysis with rebate tables
    Lane, Wendy S.
    Weatherall, James
    Gundgaard, Jens
    Pollock, Richard F.
    JOURNAL OF MEDICAL ECONOMICS, 2018, 21 (02) : 144 - 151
  • [25] Traveling Across Time Zones With Type 1 Diabetes: A Pilot Study Comparing Insulin Degludec With Insulin Glargine U100
    Bevier, Wendy C.
    Castorino, Kristin N.
    Axelrod, Ceara
    Haroush, Gal
    Farfan, Christian C.
    Shelton, Nina
    Nelson, Kristen
    Spink, Lisa A.
    Liu, Hanqing
    Kerr, David
    DIABETES CARE, 2022, 45 (01) : 67 - 73
  • [26] Relationship between A1C and Hypoglycemia Risk in Individual Patients Comparing Insulin Degludec with Insulin Glargine U100
    Philis-Tsimikas, Athena
    Lane, Wendy
    Pedersen-Bjergaard, Ulrik
    Wysham, Carol H.
    Bardtrum, Lars
    Ostoft, Signe H.
    Heller, Simon
    DIABETES, 2018, 67
  • [27] Degludec hospital trial: A randomized controlled trial comparing insulin degludec U100 and glargine U100 for the inpatient management of patients with type 2 diabetes
    Galindo, Rodolfo J.
    Pasquel, Francisco J.
    Vellanki, Priyathama
    Alicic, Radica
    Lam, David W.
    Fayfman, Maya
    Migdal, Alexandra L.
    Davis, Georgia M.
    Cardona, Saumeth
    Urrutia, Maria A.
    Perez-Guzman, Citlalli
    Zamudio-Coronado, Karla Walkiria
    Peng, Limin
    Tuttle, Katherine R.
    Umpierrez, Guillermo E.
    DIABETES OBESITY & METABOLISM, 2022, 24 (01): : 42 - 49
  • [28] More physiological circulating insulin and modulation of hepatic glucose production with insulin Glargine U300 vs U100 in type 1 diabetes
    Porcellati, F.
    Lucidi, P.
    Andreoli, A. Marinelli
    Cioli, P.
    Candeloro, P.
    Bolli, G. B.
    Fanelli, C. G.
    DIABETOLOGIA, 2017, 60 : S307 - S308
  • [29] Comparison of efficacy and safety of insulin degludec/liraglutide and insulin glargine U-100/lixisenatide in individuals with type 2 diabetes mellitus using professional continuous glucose monitoring
    Kawaguchi, Yuji
    Hajika, Yuriko
    Rinka, Maho
    Masumoto, Koji
    Sawa, Jun
    Hamazaki, Kenji
    Kumeda, Yasuro
    JOURNAL OF DIABETES INVESTIGATION, 2024, 15 (05) : 598 - 607
  • [30] A short-term cost-utility analysis of insulin degludec versus insulin glargine U100 in patients with type 1 or type 2 diabetes in Denmark
    Pollock, R. F.
    Tikkanen, C. K.
    JOURNAL OF MEDICAL ECONOMICS, 2017, 20 (03) : 213 - 220