The Effect of Insulin Degludec Versus Insulin Glargine U100 on Glucose Metrics Recorded During Continuous Glucose Monitoring in People With Type 1 Diabetes and Recurrent Nocturnal Severe Hypoglycemia

被引:0
|
作者
Brosen, Julie Maria Boggild [1 ,2 ]
Agesen, Rikke Mette [1 ,3 ]
Alibegovic, Amra Ciric [3 ,4 ]
Andersen, Henrik Ullits [2 ,4 ]
Beck-Nielsen, Henning [5 ,6 ]
Gustenhoff, Peter [7 ]
Hansen, Troels Krarup [8 ,9 ]
Hedetoft, Christoffer [10 ]
Jensen, Tonny Joran [2 ,11 ]
Juhl, Claus Bogh [6 ,12 ,13 ]
Stolberg, Charlotte Ron [6 ,12 ]
Lerche, Susanne Sogaard [14 ]
Norgaard, Kirsten [2 ,4 ,15 ]
Parving, Hans-Henrik [11 ]
Tarnow, Lise [16 ,17 ]
Thorsteinsson, Birger [1 ,2 ]
Pedersen-Bjergaard, Ulrik [1 ,2 ]
机构
[1] Copenhagen Univ Hosp, Nordsjaellands Hosp, Dept Endocrinol & Nephrol, Dyrehavevej 29, DK-3400 Hillerod, Denmark
[2] Univ Copenhagen, Fac Hlth & Med Sci, Dept Clin Med, Copenhagen, Denmark
[3] Novo Nordisk AS, Dept Med Sci, Soborg, Denmark
[4] Steno Diabet Ctr Copenhagen, Herlev, Denmark
[5] Odense Univ Hosp, Dept Endocrinol, Odense, Denmark
[6] Univ Southern Denmark, Fac Hlth & Sci, Dept Reg Hlth Res, Odense, Denmark
[7] Steno Diabet Ctr North, Aalborg, Denmark
[8] Aarhus Univ, Dept Clin Med, Aarhus, Denmark
[9] Steno Diabet Ctr Aarhus, Aarhus, Denmark
[10] Zealand Univ Hosp, Dept Internal Med, Koge, Denmark
[11] Copenhagen Univ Hosp, Dept Endocrinol, Rigshosp, Copenhagen, Denmark
[12] Univ Hosp Southwest Jutland, Dept Med, Esbjerg, Denmark
[13] Steno Diabet Ctr Odense, Odense, Denmark
[14] Lillebaelt Hosp, Dept Diabet & Hormonal Dis, Kolding, Denmark
[15] Copenhagen Univ Hosp, Hvidovre Hosp, Dept Endocrinol, Copenhagen, Denmark
[16] Steno Diabet Ctr Sjaelland, Holbaek, Denmark
[17] Copenhagen Univ Hosp, Nordsjaellands Hosp, Dept Clin Res, Hillerod, Denmark
来源
JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY | 2025年 / 19卷 / 02期
关键词
CGM; insulin analogs; time-above-range; time-below-range; time in range; type; 1; diabetes; GLYCEMIC CONTROL; BASAL INSULIN; VARIABILITY; ACCURACY; HBA(1C); RISK; CGM;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim: Comparing continuous glucose monitoring (CGM)-recorded metrics during treatment with insulin degludec (IDeg) versus insulin glargine U100 (IGlar-100) in people with type 1 diabetes (T1D) and recurrent nocturnal severe hypoglycemia. Materials and methods: This is a multicenter, two-year, randomized, crossover trial, including 149 adults with T1D and minimum one episode of nocturnal severe hypoglycemia within the last two years. Participants were randomized 1:1 to treatment with IDeg or IGlar-100 and given the option of six days of blinded CGM twice during each treatment. CGM traces were reviewed for the percentage of time-within-target glucose range (TIR), time-below-range (TBR), time-above-range (TAR), and coefficient of variation (CV). Results: Seventy-four participants were included in the analysis. Differences between treatments were greatest during the night (23:00-06:59). Treatment with IGlar-100 resulted in 54.0% vs 49.0% with IDeg TIR (70-180 mg/dL) (estimated treatment difference [ETD]: -4.6%, 95% confidence interval [CI]: -9.1, -0.0, P = .049). TBR was lower with IDeg at level 1 (54-69 mg/dL) (ETD: -1.7% [95% CI: -2.9, -0.5], P < .05) and level 2 (<54 mg/dL) (ETD: -1.3% [95% CI: -2.1, -0.5], P = .001). TAR was higher with IDeg compared with IGlar-100 at level 1 (181-250 mg/dL) (ETD: 4.0% [95% CI: 0.8, 7.3], P < .05) and level 2 (> 250 mg/dL) (ETD: 4.0% [95% CI: 0.8, 7.2], P < .05). The mean CV was lower with IDeg than that with IGlar-100 (ETD: -3.4% [95% CI: -5.6, -1.2], P < .05). Conclusion: For people with T1D suffering from recurrent nocturnal severe hypoglycemia, treatment with IDeg, compared with IGlar-100, results in a lower TBR and CV during the night at the expense of more TAR.
引用
收藏
页码:390 / 399
页数:10
相关论文
共 50 条
  • [1] The Effect of Insulin Degludec Versus Insulin Glargine U100 on Glucose Metrics Recorded During Continuous Glucose Monitoring in People With Type 1 Diabetes and Recurrent Nocturnal Severe Hypoglycemia
    Brosen, Julie Maria Boggild
    Agesen, Rikke Mette
    Alibegovic, Amra Ciric
    Andersen, Henrik Ullits
    Beck-Nielsen, Henning
    Gustenhoff, Peter
    Hansen, Troels Krarup
    Hedetoft, Christoffer
    Jensen, Tonny Joran
    Juhl, Claus Bogh
    Stolberg, Charlotte Ron
    Lerche, Susanne Sogaard
    Norgaard, Kirsten
    Parving, Hans-Henrik
    Tarnow, Lise
    Thorsteinsson, Birger
    Pedersen-Bjergaard, Ulrik
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2023,
  • [2] Continuous Glucose Monitoring-Recorded Hypoglycemia with Insulin Degludec or Insulin Glargine U100 in People with Type 1 Diabetes Prone to Nocturnal Severe Hypoglycemia
    Brosen, Julie Maria Boggild
    Agesen, Rikke Mette
    Alibegovic, Amra Ciric
    Andersen, Henrik Ullits
    Beck-Nielsen, Henning
    Gustenhoff, Peter
    Hansen, Troels Krarup
    Hedetoft, Christoffer Georg Riber
    Jensen, Tonny Joran
    Stolberg, Charlotte Ron
    Juhl, Claus Bogh
    Lerche, Susanne Sogaard
    Norgaard, Kirsten
    Parving, Hans-Henrik
    Tarnow, Lise
    Thorsteinsson, Birger
    Pedersen-Bjergaard, Ulrik
    DIABETES TECHNOLOGY & THERAPEUTICS, 2022, 24 (09) : 643 - 654
  • [3] The Effect of Insulin Degludec vs. Insulin Glargine U100 on Continuous Glucose Monitoring (CGM) Recorded Glycemic Metrics in People with Type 1 Diabetes and Recurrent Nocturnal Severe Hypoglycemia
    Brosen, Julie M.
    Agesen, Rikke
    Alibegovic, Amra Ciric
    Andersen, Henrik U.
    Gustenhoff, Peter
    Hansen, Troels K.
    Hedetoft, Christoffer
    Stolberg, Charlotte R.
    Juhl, Claus B.
    Lerche, Susanne
    Norgaard, Kirsten
    Tarnow, Lise
    Thorsteinsson, Birger
    Pedersen-Bjergaard, Ulrik
    DIABETES, 2022, 71
  • [4] Effect of insulin degludec vs insulin glargine U100 on continuous glucose monitoring recorded metrics in people with type 1 diabetes and nocturnal severe hypoglycaemia
    Brosen, J. M. B.
    Agesen, R. M.
    Alibegovic, A. C.
    Andersen, H. U.
    Gustenhoff, P.
    Hansen, T. K.
    Hedetoft, C.
    Jensen, T. J.
    Juhl, C. B.
    Stolberg, C. R.
    Lerche, S. S.
    Norgaard, K.
    Parving, H. -H.
    Tarnow, L.
    Pedersen-Bjergaard, U.
    DIABETOLOGIA, 2022, 65 (SUPPL 1) : S330 - S331
  • [5] Effect of insulin degludec versus insulin glargine U100 on nocturnal glycaemia assessed by plasma glucose profiles in people with type 1 diabetes prone to nocturnal severe hypoglycaemia
    Brosen, Julie Maria Boggild
    Agesen, Rikke Mette
    Kristensen, Peter Lommer
    Alibegovic, Amra Ciric
    Andersen, Henrik Ullits
    Beck-Nielsen, Henning
    Gustenhoff, Peter
    Hansen, Troels Krarup
    Hedetoft, Christoffer
    Jensen, Tonny
    Stolberg, Charlotte Ron
    Juhl, Claus Bogh
    Lerche, Susanne Sogaard
    Norgaard, Kirsten
    Parving, Hans-Henrik
    Tarnow, Lise
    Thorsteinsson, Birger
    Pedersen-Bjergaard, Ulrik
    DIABETES OBESITY & METABOLISM, 2023, 25 (06): : 1557 - 1565
  • [6] EFFECT OF INSULIN DEGLUDEC VERSUS INSULIN GLARGINE U100 ON OCCURRENCE OF CGM-RECORDED NOCTURNAL HYPOGLYCAEMIA IN PEOPLE WITH TYPE 1 DIABETES AND PREVIOUS NOCTURNAL SEVERE HYPOGLYCEAMIA
    Brosen, J.
    Agesen, R.
    Alibegovic, A.
    Andersen, H.
    Beck-Nielsen, H.
    Gustenhoff, P.
    Hansen, T.
    Hedetoft, C.
    Jensen, T.
    Juhl, C.
    Lerche, S.
    Norgaard, K.
    Parving, H. -H.
    Tarnow, L.
    Thorsteinsson, B.
    Pedersen-Bjergaard, U.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 : A90 - A91
  • [7] ADA Presidents' Select Abstract: Effect of Insulin Degludec vs. Insulin Glargine U100 on Occurrence of Nocturnal Hypoglycemia Assessed by Nocturnal Plasma Glucose Profiles in People with Type 1 Diabetes Prone to Nocturnal Severe Hypoglycemia
    Brosen, Julie M.
    Agesen, Rikke
    Kristensen, Peter L.
    Alibegovic, Amra Ciric
    Andersen, Henrik U.
    Gustenhoff, Peter
    Hedetoft, Christoffer
    Jensen, Tonny
    Juhl, Claus B.
    Lerche, Susanne
    Norgaard, Kirsten
    Parving, Hans-Henrik D.
    Tarnow, Lise
    Thorsteinsson, Birger
    Pedersen-Bjergaard, Ulrik
    DIABETES, 2021, 70
  • [8] Nocturnal Hypoglycemia with Insulin Degludec and Glargine U100 in Patients with Type 1 Diabetes Prone to Severe Nocturnal Hypoglycemia (HypoDeg): A CGM Substudy
    Brosen, Julie M.
    Agesen, Rikke M.
    Alibegovic, Amra Ciric
    Andersen, Henrik U.
    Gustenhoff, Peter
    Hansen, Troels K.
    Jensen, Tonny, Sr.
    Juhl, Claus B.
    Lerche, Susanne
    Norgaard, Kirsten
    Parving, Hans-Henrik D.
    Tarnow, Lise
    Thorsteinsson, Birger
    Pedersen-Bjergaard, Ulrik
    DIABETES, 2020, 69
  • [9] Effect of insulin degludec vs insulin glargine U100 on occurrence of nocturnal hypoglycaemia assessed by plasma glucose profiles in people with type 1 diabetes: HypoDeg trial
    Brosen, J. M. B.
    Agesen, R. M.
    Kristensen, P. L.
    Alibegovic, A. C.
    Andersen, H. U.
    Beck-Nielsen, H.
    Gustenhoff, P.
    Hedetoft, C.
    Jensen, T.
    Juhl, C. B.
    Lerche, S. S.
    Norgaard, K.
    Parving, H. -H.
    Tarnow, L.
    Pedersen-Bjergaard, U.
    DIABETOLOGIA, 2021, 64 (SUPPL 1) : 270 - 271
  • [10] Insulin degludec U100 is associated with lower risk for severe and symptomatic hypoglycemia as compared with insulin glargine U100 in subjects with type 1 diabetes
    Tentolouris, Anastasios
    Eleftheriadou, Ioanna
    Tentolouris, Nikolaos
    ANNALS OF TRANSLATIONAL MEDICINE, 2018, 6 (03)