Fluorescent Lateral Flow Immunoassay Based on Quantum Dots Nanobeads

被引:1
|
作者
Fan, Lingzhi [1 ]
Luo, Yue [2 ]
Yan, Wannian [1 ]
Han, Huanxing [3 ]
Zhang, Pengfei [1 ]
机构
[1] Tongji Univ, Sch Med, Shanghai Skin Dis Hosp, Dept Cent Lab, Shanghai, Peoples R China
[2] Tongji Univ, Sch Med, Dept Dermatol, Shanghai Skin Dis Hosp,Inst Dermatol, Shanghai, Peoples R China
[3] Naval Med Univ, Changzheng Hosp, Dept Pharm, Shanghai, Peoples R China
来源
关键词
SILICA NANOPARTICLES; SENSITIVE DETECTION;
D O I
10.3791/67000
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Quantum dots, also known as semiconductor nanocrystals, are novel fluorescent labels for biological imaging and sensing. However, quantum dot-antibody conjugates with small dimensions (similar to 10 nm), prepared through laborious purification procedures, exhibit limited sensitivity in detecting certain trace disease markers using lateral flow immunoassay strips. Herein, we present a method for the preparation of quantum dot nanobeads (QDNB) using a one-step emulsion evaporation method. Using the as-prepared QDNB, a fluorescent lateral flow immunoassay was fabricated to detect disease biomarkers using C-reactive protein (CRP) as an example. Unlike more sensitive as immunoassay labels due to signal amplification by encapsulating hundreds of quantum dots in one polymer composite nanobead. Moreover, the larger size of QDNBs facilitates easier centrifugation separation when conjugating QDNBs with antibodies. The fluorescent lateral flow immunoassay based on QDNBs was fabricated, and the CRP concentration in the sample was measured in 15 min. The test results can be qualitatively assessed under UV light illumination and quantitatively measured using a fluorescent reader within 15 min.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Development of a lateral flow fluorescent microsphere immunoassay for the determination of sulfamethazine in milk
    Rui Chen
    Heng Li
    Han Zhang
    Suxia Zhang
    Weimin Shi
    Jianzhong Shen
    Zhanhui Wang
    Analytical and Bioanalytical Chemistry, 2013, 405 : 6783 - 6789
  • [42] Development of a lateral flow fluorescent microsphere immunoassay for the determination of sulfamethazine in milk
    Chen, Rui
    Li, Heng
    Zhang, Han
    Zhang, Suxia
    Shi, Weimin
    Shen, Jianzhong
    Wang, Zhanhui
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (21) : 6783 - 6789
  • [43] Rapid lateral-flow immunoassay for the quantum dot-based detection of puerarin
    Qu, Huihua
    Zhang, Yue
    Qu, Baoping
    Kong, Hui
    Qin, Gaofeng
    Liu, Shuchen
    Cheng, Jinjun
    Wang, Qingguo
    Zhao, Yan
    BIOSENSORS & BIOELECTRONICS, 2016, 81 : 358 - 362
  • [44] Development of fluorescent lateral flow immunoassay for SARS-CoV-2-specific IgM and IgG based on aggregation-induced emission carbon dots
    Ju, Jian
    Zhang, Xinyu
    Li, Lin
    Regmi, Sagar
    Yang, Guoqiang
    Tang, Shixing
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2022, 10
  • [45] Smartphone based lateral flow immunoassay quantifications
    Park, Jongwon
    JOURNAL OF IMMUNOLOGICAL METHODS, 2024, 533
  • [46] Fluorescent DNA Probes Based on Quantum Dots and Core/Shell Quantum Dots
    Song, Mengmeng
    Guo, Wenjuan
    Dai, Zhao
    Qiu, Kaili
    Wei, Junfu
    ADVANCED MATERIALS DESIGN AND MECHANICS II, 2013, 372 : 115 - 118
  • [47] Sensitive and Quantitative Determination of Cardiac Troponin I Based on Silica-Encapsulated CdSe/ZnS Quantum Dots and a Fluorescence Lateral Flow Immunoassay
    Wu, Min
    Zhang, Xian
    Wu, Ruili
    Wang, Guochun
    Li, Jinjie
    Chai, Yujuan
    Shen, Huaibin
    Li, Lin Song
    ANALYTICAL LETTERS, 2020, 53 (11) : 1757 - 1773
  • [48] Applying strand displacement amplification to quantum dots-based fluorescent lateral flow assay strips for HIV-DNA detection
    Deng, Xilei
    Wang, Cong
    Gao, Ya
    Li, Jingwen
    Wen, Wei
    Zhang, Xiuhua
    Wang, Shengfu
    BIOSENSORS & BIOELECTRONICS, 2018, 105 : 211 - 217
  • [49] Dual-Fluorescent Quantum Dot Nanobead-Based Lateral Flow Immunoassay for Simultaneous Detection of C-Reactive Protein and Procalcitonin
    Tang, Xinyue
    Xia, Wenwen
    Han, Huanxing
    Wang, Yucheng
    Wang, Bolong
    Gao, Shouhong
    Zhang, Pengfei
    ACS APPLIED BIO MATERIALS, 2024, 7 (11): : 7659 - 7665
  • [50] Analysis of Human Serum Amyloid A-1 Concentrations Using a Lateral Flow Immunoassay with CdSe/ZnS Quantum Dots
    Fajri, Aidil
    Goh, Eunseo
    Lee, Sanghyuk
    Lee, Hye Jin
    APPLIED CHEMISTRY FOR ENGINEERING, 2019, 30 (04): : 429 - 434