Feasibility of Ultra-low Radiation and Contrast Medium Dosage in Aortic CTA Using Deep Learning Reconstruction at 60 kVp: An Image Quality Assessment

被引:0
|
作者
Qi, Ke [1 ]
Xu, Chensi [2 ]
Yuan, Dian [1 ]
Zhang, Yicun [1 ]
Zhang, Mengyuan [1 ]
Zhang, Weiting [1 ]
Zhang, Jiong [1 ]
You, Bojun [1 ]
Gao, Jianbo [1 ]
Liu, Jie [1 ]
机构
[1] Zhengzhou Univ, Affiliated Hosp 1, Dept Radiol, 1 Eastern Jianshe Rd, Zhengzhou 450052, Henan Province, Peoples R China
[2] Neusoft Med Syst Co Ltd, CT Business Unit, 177-1 Innovat Rd, Shenyang, Liaoning Provin, Peoples R China
关键词
Computed tomography angiography; Aorta; Low tube voltage CT; Radiation dose; Contrast media; Deep learning; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; ITERATIVE MODEL RECONSTRUCTION; LOW-TUBE-VOLTAGE; DOSE REDUCTION; CORONARY CT; OPTIMIZATION; REPAIR;
D O I
10.1016/j.acra.2024.10.042
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To assess the viability of using ultra-low radiation and contrast medium (CM) dosage in aortic computed tomography angiography (CTA) through the application of low tube voltage (60 kVp) and a novel deep learning image reconstruction algorithm (ClearInfinity, DLIR-CI). Methods: Iodine attenuation curves obtained from a phantom study informed the administration of CM protocols. Non-obese participants undergoing aortic CTA were prospectively allocated into two groups and then obtained three reconstruction groups. The conventional group (100 kVp-CV group) underwent imaging at 100 kVp and received 210 mg iodine/kg in combination with a hybrid iterative reconstruction algorithm (ClearView, HIR-CV). The experimental group was imaged at 60 kVp with 105 mg iodine/kg, while images were reconstructed with HIR-CV (60 kVp-CV group) and with DLIR-CI (60 kVp-CI group). Student's t-test was used to compare differences in CM protocol and radiation dose. One-way ANOVA compared CT attenuation, image noise, SNR, and CNR among the three reconstruction groups, while the Kruskal-Wallis H test assessed subjective image quality scores. Post hoc analysis was performed with Bonferroni correction for multiple comparisons, and consistency analysis conducted in subjective image quality assessment was measured using Cohen's kappa. Results: The radiation dose (1.12 +/- 0.23 mSv vs. 2.03 +/- 0.82 mSv) and CM dosage (19.04 +/- 3.03 mL vs. 38.11 +/- 6.47 mL) provided the reduction of 45% and 50% in the experimental group compared to the conventional group. The CT attenuation, SNR, and CNR of 60 kVp-CI were superior to or equal to those of 100 kVp-CV. Compared to the 60 kVp-CV group, images in 60 kVp-CI showed higher SNR and CNR (all P < 0.001). There was no difference between the 60 kVp-CI and 100 kVp-CV group in terms of the subjective image quality of the aorta in various locations (all P > 0.05), with 60 kVp-CI images were deemed diagnostically sufficient across all vascular segments. Conclusion: For non-obese patients, the combined use of 60 kVp and DLIR-CI algorithm can be preserving image quality while enabling radiation dose and contrast medium savings for aortic CTA compared to 100 kVp using HIR-CV. (c) 2024 The Association of University Radiologists. Published by Elsevier Inc. All rights are reserved, including those for text and data mining, AI training, and similar technologies.
引用
收藏
页码:1506 / 1516
页数:11
相关论文
共 50 条
  • [1] Image quality assessment of artificial intelligence iterative reconstruction for low dose aortic CTA: A feasibility study of 70 kVp and reduced contrast medium volume
    Li, Wanjiang
    You, Yongchun
    Zhong, Sihua
    Shuai, Tao
    Liao, Kai
    Yu, Jianqun
    Zhao, Jin
    Li, Zhenlin
    Lu, Chunyan
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 149
  • [2] Image quality assessment of artificial intelligence iterative reconstruction for low dose aortic CTA: A feasibility study of 70 kVp and reduced contrast medium volume (vol 149, 110221, 2022)
    Li, Wanjiang
    You, Yongchun
    Zhong, Sihua
    Shuai, Tao
    Liao, Kai
    Yu, Jianqun
    Zhao, Jin
    Li, Zhenlin
    Lu, Chunyan
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 152
  • [3] Deep Learning Image Reconstruction for Transcatheter Aortic Valve Implantation Planning: Image Quality, Diagnostic Performance, Contrast volume and Radiation Dose Assessment
    Zhang, Yu
    Liu, Zixuan
    Cheng, Yong
    Wang, Ziwei
    Li, Zhenlin
    Li, Jianying
    Shuai, Tao
    ACADEMIC RADIOLOGY, 2024, 31 (06) : 2268 - 2280
  • [4] CORONARY CT ANGIOGRAPHY USING ULTRA-LOW DOSE CONTRAST MEDIA: RADIATION DOSE AND IMAGE QUALITY
    Komatsu, Sei
    Imai, Atsuko
    Kodama, Kazuhisa
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (13) : E1357 - E1357
  • [5] Achieving low radiation dose and contrast agents dose in coronary CT angiography at 60-kVp ultra-low tube voltage
    He, Weiling
    Huang, Feng
    Wu, Xi
    Xie, An
    Sun, Wenjie
    Liu, Peng
    Hu, Rui
    BMC MEDICAL IMAGING, 2025, 25 (01):
  • [6] Improving the image quality of pediatric chest CT angiography with low radiation dose and contrast volume using deep learning image reconstruction
    Sun, Jihang
    Li, Haoyan
    Li, Jianying
    Yu, Tong
    Li, Michelle
    Zhou, Zuofu
    Peng, Yun
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2021, 11 (07) : 3051 - 3058
  • [7] Performance evaluation of using shorter contrast injection and 70 kVp with deep learning image reconstruction for reduced contrast medium dose and radiation dose in coronary CT angiography for children: a pilot study
    Sun, Jihang
    Li, Haoyan
    Li, Jianying
    Cao, Yongli
    Zhou, Zuofu
    Li, Michelle
    Peng, Yun
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2021, 11 (09) : 4162 - 4171
  • [8] Impact of 80 kVp with iterative reconstruction algorithm and low-dose contrast medium on the image quality of craniocervical CT angiography
    Chen, Po-An
    Chen, Chih-Wei
    Chou, Chiung-Chen
    Fu, Jui-Hsun
    Wang, Po-Chin
    Hsu, Shuo-Hsiu
    Lai, Ping-Hong
    CLINICAL IMAGING, 2020, 68 (68) : 124 - 130
  • [9] Diagnostic value of iterative reconstruction algorithm in low kV CT angiography (CTA) with low contrast medium volume for transcatheter aortic valve implantation (TAVI) planning: image quality and radiation dose exposure
    Franzesi, Cammillo R. Talei
    Ippolito, Davide
    Riva, Luca
    Fior, Davide
    Cangiotti, Cecilia
    Sironi, Sandro
    BRITISH JOURNAL OF RADIOLOGY, 2018, 91 (1092):
  • [10] Deep learning based ultra-low dose fan-beam computed tomography image enhancement algorithm: Feasibility study in image quality for radiotherapy
    Jiang, Hua
    Qin, Songbing
    Jia, Lecheng
    Wei, Ziquan
    Xiong, Weiqi
    Xu, Wentao
    Gong, Wei
    Zhang, Wei
    Yu, Liqin
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024,