Comparative Analysis of Real-World Clinical Outcomes of a Novel Pulsed Field Ablation System for Pulmonary Vein Isolation: The Prospective CIRCLE-PVI Study

被引:0
|
作者
Katov, Lyuboslav [1 ]
Teumer, Yannick [1 ]
Bothner, Carlo [1 ]
Rottbauer, Wolfgang [1 ]
Weinmann-Emhardt, Karolina [1 ]
机构
[1] Ulm Univ, Heart Ctr, Dept Cardiol, Albert Einstein Allee 23, D-89081 Ulm, Germany
关键词
atrial fibrillation; pulsed field ablation; pulmonary vein isolation; circular pulsed field ablation catheter; ATRIAL-FIBRILLATION;
D O I
10.3390/jcm13237040
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Pulsed field ablation (PFA) represents a novel non-thermal approach for treating atrial fibrillation (AF) through pulmonary vein isolation (PVI). By utilizing irreversible electroporation, PFA creates lesions with minimal impact on adjacent tissues. This study investigates the procedural outcomes and safety of a novel circular PFA catheter in comparison to an established PFA system in a real-world clinical setting. Methods: This prospective, single-center study enrolled 125 consecutive patients with symptomatic paroxysmal or persistent AF undergoing first-time PVI with PFA at Ulm University Heart Center. Twenty-five patients underwent PFA PVI using a novel PFA system (PulseSelectTM, Medtronic, Dublin, Ireland) which incorporates a new circular catheter design and additional features such as ECG-triggered energy application and phrenic nerve capture testing. In comparison, 100 patients were treated using the established PFA system (FarapulseTM, Boston Scientific, Marlborough, MA, USA). Results: Acute PVI was achieved in 100% of the patients. Procedure duration, total left atrial (LA) time and fluoroscopy time remained comparable between both groups. The total number of energy deliveries was higher with the novel circular PFA catheter (34.0 vs. 32.0; p < 0.001). No procedure-related complications, including pericardial tamponade, phrenic nerve injury, atrial-esophageal fistula, vascular complications, embolisms, malignant cardiac arrhythmias, or coronary spasms were observed. Conclusions: The novel and the established PFA systems demonstrated comparable results in terms of procedure duration, fluoroscopy time, and LA time. In the hands of experienced operators, the novel circular PFA system enables an effective, consistent, and safe approach to successful PFA PVI.
引用
收藏
页数:13
相关论文
共 34 条
  • [21] Pulmonary Vein Isolation with Pulsed Field Ablation and Size-Adjustable Cryo-Balloon: A Comparative Procedural Analysis of First-Time Use
    Katov, Lyuboslav
    Teumer, Yannick
    Bothner, Carlo
    Rottbauer, Wolfgang
    Weinmann-Emhardt, Karolina
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (11)
  • [22] Application of a circular-shaped pulsed field ablation catheter with magnetic sensors for pulmonary vein isolation: a multi-centre clinical study report
    Wang, Yan
    Lai, Heng Li
    Chen, Qi
    Liu, Hao
    Liu, Qi Ming
    Huang, Wei Bin
    Tao, Yu
    Xiong, Qingmei
    Zhou, Ning
    Zhao, Chunxia
    Qiu, Jie
    Xu, Ziqin
    Wang, Dao Wen
    EUROPACE, 2024, 26 (04):
  • [23] Pulmonary vein isolation cryoablation for patients with persistent and long-standing persistent atrial fibrillation: Clinical outcomes from the real-world multicenter observational project
    Tondo, Claudio
    Iacopino, Saverio
    Pieragnoli, Paolo
    Molon, Giulio
    Verlato, Roberto
    Curnis, Antonio
    Landolina, Maurizio
    Allocca, Giuseppe
    Arena, Giuseppe
    Fassini, Gaetano
    Sciarra, Luigi
    Luzi, Mario
    Manfrin, Massimiliano
    Padeletti, Luigi
    HEART RHYTHM, 2018, 15 (03) : 363 - 368
  • [24] Pulsed-field ablation-based pulmonary vein isolation: acute safety, efficacy and short-term follow-up in a multi-center real world scenario
    Lemoine, Marc D.
    Fink, Thomas
    Mencke, Celine
    Schleberger, Ruben
    My, Ilaria
    Obergassel, Julius
    Bergau, Leonard
    Sciacca, Vanessa
    Rottner, Laura
    Moser, Julia
    Kany, Shinwan
    Moser, Fabian
    Munkler, Paula
    Dinshaw, Leon
    Kirchhof, Paulus
    Reissmann, Bruno
    Ouyang, Feifan
    Sommer, Philipp
    Sohns, Christian
    Rillig, Andreas
    Metzner, Andreas
    CLINICAL RESEARCH IN CARDIOLOGY, 2023, 112 (06) : 795 - 806
  • [25] Pulsed-field ablation-based pulmonary vein isolation: acute safety, efficacy and short-term follow-up in a multi-center real world scenario
    Marc D. Lemoine
    Thomas Fink
    Celine Mencke
    Ruben Schleberger
    Ilaria My
    Julius Obergassel
    Leonard Bergau
    Vanessa Sciacca
    Laura Rottner
    Julia Moser
    Shinwan Kany
    Fabian Moser
    Paula Münkler
    Leon Dinshaw
    Paulus Kirchhof
    Bruno Reissmann
    Feifan Ouyang
    Philipp Sommer
    Christian Sohns
    Andreas Rillig
    Andreas Metzner
    Clinical Research in Cardiology, 2023, 112 : 795 - 806
  • [26] 'Single-shot' pulmonary vein isolation using a novel lotos pulsed field ablation catheter: a pre-clinical evaluation of feasibility, safety, and 30-day efficacy
    Pu, Sijia
    Liu, Fangzhou
    Chen, Yuhan
    Luo, Cihua
    Li, Peng
    Chen, Yanlin
    Fu, Lu
    Liu, Huiyi
    Ye, Xingdong
    Wu, Shulin
    Xue, Yumei
    Lin, Weidong
    EUROPACE, 2023, 26 (01):
  • [27] Outcomes of very high-power short-duration ablation using 90w for pulmonary vein isolation in patients with atrial fibrillation: a real world observation study
    Mavilakandy, A.
    Antoun, I.
    Kotb, A.
    Koev, I. M.
    Barker, J.
    Vali, Z.
    Sidhu, B.
    Pooranachandran, V.
    Li, X.
    Ng, G. A.
    EUROPEAN HEART JOURNAL, 2022, 43 : 470 - 470
  • [28] SAFETY AND OUTCOMES OF VERY HIGH-POWER SHORT-DURATION ABLATION USING 90W FOR PULMONARY VEIN ISOLATION IN PATIENTS WITH ATRIAL FIBRILLATION: A REAL WORLD OBSERVATION STUDY
    Mavilakandy, Akash
    Antoun, Ibrahim
    Kotb, Ahmed
    Barker, Joseph
    Koev, Ivelin M.
    Sidhu, Bharat
    Vali, Zakariyya
    Pooranachandran, Vivetha
    Li, Xin
    Ng, G. Andre
    HEART, 2022, 108 : A71 - A72
  • [29] Real-world evidence with The Rezum System: A retrospective study and comparative analysis on the efficacy and safety of 12 month outcomes across a broad range of prostate volumes
    Ines, Matthew
    Babar, Mustufa
    Singh, Sandeep
    Iqbal, Nazifa
    Ciatto, Michael
    PROSTATE, 2021, 81 (13): : 956 - 970
  • [30] FIRST INTERIM ANALYSIS OF PATIENT-REPORTED OUTCOMES IN VIEW STUDY: A MULTICENTER, SINGLEARM, PROSPECTIVE, NON-INTERVENTIONAL STUDY OF VONOPRAZAN IN REAL-WORLD CLINICAL PRACTICE IN CHINA
    Xiao, Y.
    Wang, Q.
    Li, G.
    Nail, A.
    Song, Q.
    Xie, L.
    Chen, M.
    VALUE IN HEALTH, 2023, 26 (12) : S448 - S449