High-Frequency Static Pressure Measurements in the T5 Reflected Shock Tunnel

被引:0
|
作者
Yu, Wesley M. [1 ]
Luo, Ying [1 ]
Austin, Joanna M. [1 ]
Hornung, Hans G. [1 ]
Finch, Peter M. [2 ]
Schwartz, Tal [3 ]
Strand, Christopher L. [2 ]
Hanson, Ronald K. [2 ]
机构
[1] CALTECH, Grad Aerosp Labs, 1200 E Calif Blvd,MC 105-50, Pasadena, CA 91125 USA
[2] Stanford Univ, Thermofluids Energy & Prop Syst Lab, Thermosci Div, Mech Engn, 452 Escondido Mall,Bldg 520, Stanford, CA 94305 USA
[3] Stanford Univ, Thermofluids Energy & Prop Syst Lab, Thermosci Div, Aeronaut & Astronaut, 452 Escondido Mall,Bldg 520, Stanford, CA 94305 USA
来源
关键词
D O I
暂无
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
Accurate time-resolved static pressure measurements are key to characterizing the freestream thermodynamic state in hypervelocity reflected shock tunnels. A series of three static pressure probes were built for use in the T5 Free-Piston Shock Tunnel at the California Institute of Technology based on the design of Behrens. Simultaneously, Tunable Diode Laser Absorption Spectroscopy (TDLAS) was used to infer static pressure from the pressure broadening of absorption features in nitric oxide rovibrational spectroscopic transitions from the mid-infrared fundamental band. Test conditions covered stagnation enthalpies from 8 to 16 MJ/kg and freestream pressures from 7 to 27 kPa. The pressure measurements from the first two static probe generations agreed in magnitude with the TDLAS pressure within error, but showed very different temporal responses due to the slower time responses of the two probes. Subsequently, a quicker time response static probe was designed and deployed in T5 in the 8 MJ/kg and 16 MJ/kg conditions. The pressure traces from the new probe agreed well in both magnitude and temporal response with the TDLAS-inferred pressure in both conditions. In addition, the new probe was able to resolve subtle temporal differences between differently tailored versions of the same condition. The updated static probe design allows for simultaneous high-frequency pressure measurement with test models and increases confidence in pressure broadening TDLAS measurements in high-enthalpy ground test facilities.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] High-frequency Characterization of Hydraulic Shock Absorbers
    Rieß, Sebastian
    Hansmann, Jan
    Kaal, William
    Herold, Sven
    ATZ worldwide, 2019, 121 (03) : 76 - 80
  • [42] HIGH-FREQUENCY HIGH-POWER OPERATION OF TUNNEL DIODES
    KIM, CS
    BRANDLI, A
    IRE TRANSACTIONS ON CIRCUIT THEORY, 1961, CT 8 (04): : 416 - &
  • [43] WAFER CHARGING MONITORED BY HIGH-FREQUENCY AND QUASI-STATIC C-V MEASUREMENTS
    EN, B
    CHEUNG, NW
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1993, 74 (1-2): : 311 - 313
  • [44] Property of high-frequency pressure measurement
    Pieniazek, Jacek
    Ciecinski, Piotr
    Ficek, Daniel
    Szumski, Marek
    2022 IEEE INTERNATIONAL WORKSHOP ON METROLOGY FOR AEROSPACE (IEEE METROAEROSPACE 2022), 2022, : 33 - 37
  • [45] HIGH-FREQUENCY POSITIVE PRESSURE VENTILATION
    SJOSTRAND, UH
    INTERNATIONAL ANESTHESIOLOGY CLINICS, 1983, 21 (02) : 59 - 81
  • [46] Influence of Diaphragms on Pressure and Heat Flux Measurements in a Shock Tunnel
    Jang, Byungkook
    Kim, Elliott Donghyun
    Park, Gisu
    INTERNATIONAL JOURNAL OF AERONAUTICAL AND SPACE SCIENCES, 2024,
  • [47] HIGH-FREQUENCY HIGH-POWER STATIC INDUCTION TRANSISTOR
    NISHIZAWA, JI
    YAMAMOTO, K
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 1978, 25 (03) : 314 - 322
  • [48] HIGH-FREQUENCY IMPEDANCE OF SUPERCONDUCTING TUNNEL-JUNCTIONS
    JABLONSKI, DG
    JOURNAL OF LOW TEMPERATURE PHYSICS, 1983, 51 (3-4) : 433 - 451
  • [49] HIGH-FREQUENCY LIMITS OF SUPERCONDUCTING TUNNEL JUNCTION MIXERS
    WINKLER, D
    CLAESON, T
    JOURNAL OF APPLIED PHYSICS, 1987, 62 (11) : 4482 - 4498
  • [50] High-frequency operation potential of the tunnel emitter transistor
    Aderstedt, E
    Lundgren, P
    SOLID-STATE ELECTRONICS, 2002, 46 (07) : 1033 - 1037