Use of artificial intelligence to predict outcomes in mild aortic valve stenosis

被引:0
|
作者
Julakanti, Raghav R. [1 ]
Padang, Ratnasari [1 ]
Scott, Christopher G. [2 ]
Dahl, Jordi [1 ]
Al-Shakarchi, Nader J. [3 ]
Metzger, Coby [4 ]
Lanyado, Alon [4 ]
Jackson, John, I [1 ]
Nkomo, Vuyisile T. [1 ]
Pellikka, Patricia A. [1 ]
机构
[1] Mayo Clin, Dept Cardiovasc Med, 200 First St SW, Rochester, MN 55905 USA
[2] Mayo Clin, Div Biomed Stat & Informat, Rochester, MN 55905 USA
[3] Mayo Clin, Dept Med, Rochester, MN USA
[4] Medial EarlySign, Hod Hasharon, Israel
来源
关键词
Artificial intelligence; Aortic stenosis; Echocardiography; Valve disease; Machine learning; RISK;
D O I
10.1093/ehjdh/ztae085
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Aortic stenosis (AS) is a common and progressive disease, which, if left untreated, results in increased morbidity and mortality. Monitoring and follow-up care can be challenging due to significant variability in disease progression. This study aimed to develop machine learning models to predict the risks of disease progression and mortality in patients with mild AS.Methods and results A comprehensive database including 9611 patients with serial transthoracic echocardiograms was collected from a single institution across three clinical sites. The data set included parameters from echocardiograms, electrocardiograms, laboratory values, and diagnosis codes. Data from a single clinical site were preserved as an independent test group. Machine learning models were trained to identify progression to severe stenosis and all-cause mortality and tested in their performance for endpoints at 2 and 5 years. In the independent test group, the AS progression model differentiated those with progression to severe AS within 2 and 5 years with an area under the curve (AUC) of 0.86 for both. The feature of greatest importance was aortic valve mean gradient, followed by other valve haemodynamic measurements including valve area and dimensionless index. The mortality model identified those with mortality within 2 and 5 years with an AUC of 0.84 and 0.87, respectively. Smaller reduced-input validation models had similarly robust findings.Conclusion Machine learning models can be used in patients with mild AS to identify those at high risk of disease progression and mortality. Implementation of such models may facilitate real-time, patient-specific follow-up recommendations.
引用
收藏
页码:63 / 72
页数:10
相关论文
共 50 条
  • [41] Classification of severe aortic stenosis and outcomes after aortic valve replacement
    Yura Ahn
    Se Jin Choi
    Soyeoun Lim
    Joon Bum Kim
    Jong-Min Song
    Duk-Hyun Kang
    Jae-Kwan Song
    Hwa Jung Kim
    Joon-Won Kang
    Dong Hyun Yang
    Dae-Hee Kim
    Hyun Jung Koo
    Scientific Reports, 12
  • [42] Predicted outcomes after aortic valve replacement in octogenarians with aortic stenosis
    Piper, C.
    Hering, D.
    Kleikamp, G.
    Koerfer, R.
    Horstkotte, D.
    AORTIC ROOT SURGERY: THE BIOLOGICAL SOLUTION, 2010, : 523 - +
  • [43] Echocardiographic aortic valve calcification and outcomes in women and men with aortic stenosis
    Thomassen, Henrik K.
    Cioffi, Giovanni
    Gerdts, Eva
    Einarsen, Eigir
    Midtbo, Helga Bergljot
    Mancusi, Costantino
    Cramariuc, Dana
    HEART, 2017, 103 (20) : 1619 - 1624
  • [44] Classification of severe aortic stenosis and outcomes after aortic valve replacement
    Ahn, Yura
    Choi, Se Jin
    Lim, Soyeoun
    Kim, Joon Bum
    Song, Jong-Min
    Kang, Duk-Hyun
    Song, Jae-Kwan
    Kim, Hwa Jung
    Kang, Joon-Won
    Yang, Dong Hyun
    Kim, Dae-Hee
    Koo, Hyun Jung
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [45] Balloon-Expandable Transcatheter Aortic Valve Replacement in Patients with Severe Aortic Stenosis and Mild Aortic Valve Calcification
    Abramowitz, Yigal
    Jilaihawi, Hasan
    Chakravarty, Tarun
    Kashif, Mohammad
    Kazuno, Yoshio
    Maeno, Yoshio
    Takahashi, Nobuyuki
    Kawamori, Hiroyuki
    Sharma, Rahul P.
    Cox, Justin
    Cheng, Wen
    Makkar, Raj
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (15) : B257 - B257
  • [46] On-device artificial intelligence: mobile solution for detecting severe aortic valve stenosis based on heart sounds
    Makimoto, H.
    Shiraga, T.
    Kohlmann, B.
    Magnisali, C. -E.
    Schenk, R.
    Gerguri, S.
    Motoyama, N.
    Clasen, L.
    Bejinariu, A.
    Schmidt, J.
    Brinkmeyer, C.
    Westenfeld, R.
    Zeus, T.
    Kelm, M.
    EUROPEAN HEART JOURNAL, 2021, 42 : 3053 - 3053
  • [47] Outcomes of Mild Aortic Regurgitation After Transcatheter Aortic Valve Replacement
    Chahine, Johnny
    Kadri, Amer N.
    Gajulapalli, Rama Dilip
    Lak, Hassan
    Krishnaswamy, Amar
    Reed, Grant
    Perez, Oscar
    Puri, Rishi
    Popovic, Zoran
    Verma, Beni Rai
    Kaur, Manpreet
    Gad, Mohamed M.
    Nair, Raunak M.
    Jaber, Wael
    Yun, James
    Schoenhagen, Paul
    Harb, Serge C.
    Tuzcu, E. Murat
    Svensson, Lars G.
    Kapadia, Samir R.
    STRUCTURAL HEART-THE JOURNAL OF THE HEART TEAM, 2021, 5 (02): : 201 - 207
  • [48] Artificial Intelligence Driven Wearable 2-minute Seismocardiography Test for Detection of Aortic Valve Stenosis Severity
    Johnson, Ethan M.
    Robinson, Joshua D.
    Rigsby, Cynthia K.
    McCarthy, Patrick M.
    Malaisrie, S. C.
    Allen, Bradley D.
    Barker, Alexander J.
    Markl, Michael
    CIRCULATION, 2022, 146
  • [49] Will Artificial Intelligence Deliver Precision Medicine for Patients With Aortic Stenosis?
    Bruining, Nico
    Jaegere, Peter P. T. de
    JACC-CARDIOVASCULAR INTERVENTIONS, 2021, 14 (19) : 2141 - 2143
  • [50] Artificial intelligence-based stethoscope for the diagnosis of aortic stenosis
    Ghanayim, T.
    Bachner-Hinenzon, N.
    Hanuka, D.
    Adler, D.
    Adawi, S.
    Shiran, A.
    EUROPEAN HEART JOURNAL, 2021, 42 : 1588 - 1588