Pilot-scale CO2 capture demonstration of stripper interheating using 30 wt% MEA at a Waste-to-Energy facility

被引:0
|
作者
Vinjarapu, Sai Hema Bhavya [1 ]
Neerup, Randi [1 ]
Larsen, Anders Hellerup [1 ]
Villadsen, Sebastian Nis Bay [1 ]
Jensen, Soren [2 ]
Karlsson, Jakob Lindkvist [2 ]
Kappel, Jannik [3 ]
Lassen, Henrik [3 ]
Blinksbjerg, Peter [3 ]
von Solms, Nicolas [1 ]
Fosbol, Philip Loldrup [1 ]
机构
[1] Tech Univ Denmark DTU, Ctr Energy Resources Engn CERE, Dept Chem Engn, Soltofts Plads,Bldg 229, DK-2800 Lyngby, Denmark
[2] Pentair Union Engn AS, Snaremosevej 27, DK-7000 Fredericia, Denmark
[3] ARC, Amager Bakke, Vindmollevej 6, DK-2300 Copenhagen, Denmark
关键词
Climate action; Stripper interheating; Heat integration; Pilot scale demonstration; Process optimisation; TECHNOECONOMIC ASSESSMENT; AQUEOUS MONOETHANOLAMINE; POWER-PLANTS; FLUE-GAS; TECHNOLOGY; CONFIGURATIONS; PERFORMANCE; AMINE; INTEGRATION;
D O I
10.1016/j.energy.2025.134973
中图分类号
O414.1 [热力学];
学科分类号
摘要
Post-combustion CO2 capture is a widely recognised technology for controlling industrial CO2 emissions. However, issues like the substantial energy demands for solvent regeneration still need to be solved. The current work aims to discuss the outcomes of process optimisation within a pilot-scale CO2 capture facility by implementing interheating in the stripper to reduce energy consumption. The pilot-scale experiments were executed at Amager Bakke, a Waste-to-Energy plant in Copenhagen, Denmark. These tests used 30 wt% Monoethanolamine as the solvent. A semi-lean solvent from the middle of the stripper is withdrawn for external heating by an interheater and fed to the stripper at the same height. A steam generator with adjustable electrical duty is used as the heat source for the interheater. The novelty of this work lies in the pilot scale demonstration of stripper interheating at an industrial facility, which has seldom been done. The objective is to experimentally demonstrate the performance of the Interheating configuration at the pilot scale and analyse the potential improvements in the energy consumption of the process. The interheating experiments were conducted by varying the reboiler duty in the range of 12 to 20 kW and the interheater duty in the range of 2 to 5 kW while maintaining a solvent flow of 267 kg/h and a flue gas flow of 99 kg/h. The results provide several possible scenarios, are discussed in detail, and are compared to previously obtained base case results. While maintaining a capture efficiency of around 83%, stripper interheating has demonstrated a specific reboiler duty of 2.71 GJ/tonne CO2 compared to 3.71 GJ/tonne CO2 achieved by the base case operation. A 3% reduction in the specific reboiler duty was achieved by interheating at a capture efficiency slightly over 90%. A preliminary model based on the experimental results has shown a further reduction of SRD to 2.25 GJ/tonne CO2 at high capture efficiencies.
引用
收藏
页数:25
相关论文
共 50 条
  • [21] Pilot-scale investigation of an innovative process for biogas upgrading with CO2 capture and storage
    Baciocchi, Renato
    EnnioCarnevale
    GiuliaCosta
    Lombardi, Lidia
    Olivieri, Tommaso
    Paradisi, Alessandro
    Zanchi, Laura
    Zingaretti, Daniela
    GHGT-11, 2013, 37 : 6026 - 6034
  • [22] CO2 Capture and Development of an Advanced Pilot-Scale Cryogenic Separation and Compression Unit
    Zanganeh, Kourosh E.
    Shafeen, Ahmed
    Salvador, Carlos
    GREENHOUSE GAS CONTROL TECHNOLOGIES 9, 2009, 1 (01): : 247 - 252
  • [23] Pilot-Scale Demonstration of Oxy-SER steam Gasification: Production of syngas with Pre-Combustion CO2 capture
    Schweitzer, D.
    Beirow, M.
    Gredinger, A.
    Armbrust, N.
    Waizmann, G.
    Dieter, H.
    Scheffknecht, G.
    8TH TRONDHEIM CONFERENCE ON CO2 CAPTURE, TRANSPORT AND STORAGE, 2016, 86 : 56 - 68
  • [24] Analysis of unusual scale build-up in a CO2 injection well for a pilot-scale CO2 storage demonstration project
    Sminchak, Joel
    Zeller, Evan
    Bhattacharya, Indrajit
    GREENHOUSE GASES-SCIENCE AND TECHNOLOGY, 2014, 4 (03): : 357 - 365
  • [25] A Sequential Method for Determining Optimal Stripper Pressure and Terminal Pressure in CO2 Capture and Liquefaction Process Using MEA
    Park, Taekyoon
    Bae, Jaehan
    Lee, Chang Jun
    Lee, Jong Min
    IFAC PAPERSONLINE, 2016, 49 (07): : 657 - 662
  • [26] A semi-analytical method for determining the optimal stripper pressure in CO2 capture and liquefaction using monoethanolamine (MEA)
    Park, Taekyoon
    Lee, Seok Goo
    Kim, Sung Ho
    Lee, Ung
    Han, Chonghun
    Lee, Jong Min
    INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2016, 46 : 271 - 281
  • [27] Modeling and assessing the integration of CO2 capture in waste-to-energy plants delivering district heating
    Otgonbayar, Tuvshinjargal
    Mazzotti, Marco
    ENERGY, 2024, 290
  • [28] Screening CO2 capture test for cement plants using a lab scale Calcium Looping pilot facility
    Alonso, Monica
    Arias, Borja
    Mendez, Alberto
    Fuentes, Fernando
    Carlos Abanades, J.
    13TH INTERNATIONAL CONFERENCE ON GREENHOUSE GAS CONTROL TECHNOLOGIES, GHGT-13, 2017, 114 : 53 - 56
  • [29] Hydrodynamic characteristics of a pilot-scale cold model of a CO2 capture fluidised bed reactor
    Cotton, A.
    Patchigolla, K.
    Oakey, J. E.
    POWDER TECHNOLOGY, 2013, 235 : 1060 - 1069
  • [30] Energy Performance of Advanced Reboiled and Flash Stripper Configurations for CO2 Capture Using Monoethanolamine
    Rezazadeh, Fatemeh
    Gale, William F.
    Lin, Yu-Jeng
    Rochelle, Gary T.
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2016, 55 (16) : 4622 - 4631