Evolution of autoimmune diagnostics over the past 10 years: lessons learned from the UK NEQAS external quality assessment EQA programs

被引:0
|
作者
Garrafa, Emirena [2 ,3 ]
Carbone, Teresa [4 ]
Infantino, Maria [1 ]
Anzivino, Pierluigi [5 ]
Boni, Michela [6 ]
Ghisellini, Sara [6 ]
Muraro, Valentina [7 ]
Roselli, Daniele [8 ]
Trevisan, Maria Teresa [9 ]
Patel, Dina [10 ]
Bizzaro, Nicola [11 ]
机构
[1] San Giovanni Dio Hosp, Lab Immunol & Allergy, Florence, Italy
[2] Univ Brescia, DMMT, Brescia, Italy
[3] Spedali Civil Brescia, Dept Lab Diag, Brescia, Italy
[4] San Carlo Hosp, Immunopathol Lab, Potenza, Italy
[5] APSS Trento, Dept Labs, Multizone Operating Unit Clin Pathol Lab, Trento, Italy
[6] S Anna Univ Hosp, Clin Pathol Unit, Ferrara, Italy
[7] ULSS5 Polesana, Dept Serv, Lab Med, Rovigo, Italy
[8] Univ Bari, Aldo Moro Med Sch, Dept Precis & Regenerat Med & Ionian Area, Bari, Italy
[9] Fracastoro Hosp, Dept Serv, Lab Clin Pathol, AULSS9 Scaligera, S Bonifacio, Italy
[10] UK NEQAS Immunol Immunochem & Allergy, Sheffield, England
[11] Azienda Sanitria Univ Integrata, Lab Clin Pathol, Udine, Italy
关键词
external quality assessment; harmonization; immunoassays; UK NEQAS; WORKING GROUP RECOMMENDATIONS;
D O I
10.1515/cclm-2024-0781
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives External quality assessment (EQA) programs play a pivotal role in harmonizing laboratory practices, offering users a benchmark system to evaluate their own performance and identify areas requiring improvement. The objective of this study was to go through and analyze the UK NEQAS "Immunology, Immunochemistry and Allergy" EQA reports between 2012 and 2021 to assess the overall level of harmonization in autoimmune diagnostics and identify areas requiring improvement for future actions.Methods The EQA programs reviewed included anti-nuclear (ANA), anti-dsDNA, anti-centromere, anti-extractable nuclear antigen (ENA), anti-phospholipids, anti-neutrophil cytoplasm (ANCA), anti-proteinase 3 (PR3), anti-myeloperoxidase (MPO), anti-glomerular basement membrane (GBM), rheumatoid factor (RF), anti-citrullinated protein antibodies (ACPA), mitochondrial (AMA), liver-kidney-microsomal (LKM), smooth muscle (ASMA), APCA, and celiac disease antibodies.Results In the analyzed period, the number in participating laboratories showed an increase for almost all programs. Among solid phase methods, the use of ELISA techniques showed a progressive reduction, while new technologies, such as the fluoroenzymatic immunoassay, chemiluminescence immunoassay, Luminex and immunoblot showed an increased number of users. The number of results complying with the expected negative or positive target slightly increased for almost all antibodies in the last decade. A description of the most frequent causes of mistakes or misinterpretation for each specific test and method is also provided in this study.Conclusions Although numerous challenges need to be addressed in the area of autoantibody detection to enhance testing quality and attain higher harmonization, the period analyzed revealed that the ever-expanding range of autoantibodies, coupled with the introduction of new tests and methodologies and the advent of automated platforms, has brought about significant changes in autoimmune diagnostics.
引用
收藏
页数:7
相关论文
共 36 条
  • [21] Application of Digital Image Analysis for the Assessment of HER2-low in Breast Cancer-Comparison with Visual Assessments Performed at The UK National External Quality Assessment Scheme for Immunocytochemistry and In-Situ Hybridisation (UK NEQAS ICC & ISH) HER2-low EQA Programme
    Zabaglo, Lila
    Parry, Suzanne
    Wilkinson, Dawn
    Dodson, Andrew
    LABORATORY INVESTIGATION, 2025, 105 (03)
  • [22] Potentially clinically important inaccuracies in testing for the lupus anticoagulant: an analysis of results from three surveys of the UK National External Quality Assessment Scheme (NEQAS) for blood coagulation
    Jennings, I
    Kitchen, S
    Woods, TAL
    Preston, FE
    Greaves, M
    THROMBOSIS AND HAEMOSTASIS, 1997, 77 (05) : 934 - 937
  • [23] Analytical performance specifications for trace elements in biological fluids derived from six countries federated external quality assessment schemes over 10 years
    Arnaud, Josiane
    Weykamp, Cas
    Wenzel, Ross
    Patriarca, Marina
    Gonzalez-Estecha, Montserrat
    Janssen, Liesbeth
    Fofou-Caillierez, Maatem Beatrice
    Alemany, Montserrat Ventura
    Patriarca, Valeria
    de Graaf, Irene
    Persoons, Renaud
    Panades, Mariona
    China, Bernard
    te Winkel, Marieke
    van der Vuurst, Hans
    Thelen, Marc
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2025, 63 (02) : 300 - 310
  • [24] HLA TYPING TO THE 3RD AND 4TH FIELD RESOLUTION: RESULTS FROM THE UK NEQAS FOR H&I PILOT EXTERNAL QUALITY ASSESSMENT SCHEME
    Pritchard, Deborah L.
    Rees, M. T.
    HLA, 2018, 91 (05) : 418 - 418
  • [25] Too Risky to Use, or Too Risky Not to? Lessons Learned From Over 30 Years of Research on Forensic Risk Assessment With Indigenous Persons
    Olver, Mark E.
    Stockdale, Keira C.
    Helmus, L. Maaike
    Woods, Phil
    Termeer, Jordan
    Prince, Jessica
    PSYCHOLOGICAL BULLETIN, 2024, 150 (05) : 487 - 553
  • [26] What can we learn from old wetlands? Lessons that have been learned and some that may have been forgotten over the past 20 years
    Cooper, Paul
    DESALINATION, 2009, 246 (1-3) : 11 - 26
  • [27] Learnings from two years of external quality assessment (EQA) for BRCA1/BRCA2 testing in metastatic castration-resistant prostate cancer (mCRPC)
    Williams, V.
    Fairley, J. A.
    Woodcock, M.
    Cheetham, M. H.
    Wolstenholme, N. L.
    Deans, Z. C.
    Patton, S. J.
    VIRCHOWS ARCHIV, 2022, 481 (SUPPL 1) : S186 - S186
  • [28] Flow cytometric CD34+ stem cell enumeration: Lessons from nine years' external quality assessment within the Benelux countries
    Levering, Wilfried H. B. M.
    Preijers, Frank W. M. B.
    van Wieringen, Wessel N.
    Kraan, Jaco
    van Beers, Wil A. M.
    Sintnicolaas, Kees
    van Rhenen, Dick J.
    Gratama, Jan W.
    CYTOMETRY PART B-CLINICAL CYTOMETRY, 2007, 72B (03) : 178 - 188
  • [30] Lessons from external quality assessment (EQA) for BRCA1 and BRCA2 testing in hereditary breast, ovarian, pancreatic and prostate cancer - are large genomic rearrangements ( LGR) being missed?
    Williams, V.
    Fairley, J.
    Maqsood, A. R.
    Cheetham, M. H.
    Wolstenholme, N. L.
    Deans, S.
    Patton, S. J.
    VIRCHOWS ARCHIV, 2024, 485 : S101 - S102