Transvenous extraction of conduction system and lumenless pacing leads

被引:0
|
作者
Wagner, Ethan S. [1 ]
Lewis, Robert K. [2 ]
Pokorney, Sean D. [2 ]
Hegland, Donald D. [2 ]
Friedman, Daniel J. [2 ]
Piccini, Jonathan P. [2 ]
机构
[1] Duke Univ, Sch Med, Durham, NC USA
[2] Duke Univ Hosp, Dept Med, Div Cardiol, Clin Cardiac Electrophysiol Sect, Durham, NC USA
关键词
conduction system pacing; His bundle pacing; laser lead extraction; left bundle branch area pacing; transvenous lead extraction; EXPERT CONSENSUS STATEMENT; PACEMAKER;
D O I
10.1111/jce.16467
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
IntroductionConduction system pacing (CSP), often accomplished with lumenless pacing leads, is increasingly employed to achieve physiologic ventricular activation. There are limited data on the extraction of these leads. The objective of this study was to describe the safety and efficacy of extraction of CSP pacing leads and compare outcomes with extraction of non-CSP lumenless leads.MethodsPatients undergoing CSP/non-CSP lumenless lead removal were included. Outcomes of interest included rates of complete procedural success, complications, and successful reimplantation.ResultsOverall, 23 patients were included (n = 14 with CSP and n = 9 with non-CSP lumenless leads implanted in the right atrium, right ventricle, or septum). The mean age was 52.7 +/- 24.0 years, 30% were female, and the mean lead age was 4.5 +/- 4.4 years. The complete procedural success rate was 100%. One serious complication occurred in the non-CSP group but was unrelated to the lead of interest. Manual traction alone was successful in 57% of CSP cases (mean lead age 2.4 +/- 1.7 years) and in 11% of non-CSP cases (mean lead age 7.9 +/- 5.3 years). Laser sheaths were used in 43% of CSP cases and 89% of non-CSP cases; rotational cutting tools were used in no CSP cases and in 33% of non-CSP cases. Reimplantation in the conduction system was attempted with a left bundle branch pacing lead and successful in 80% (n = 4/5).ConclusionExtraction of CSP and non-CSP lumenless leads is feasible with a high success rate and a good safety profile. CSP reimplantation after extraction is also feasible with good electrical performance. Extraction of CSP and non-CSP lumenless leads is feasible with a high success rate and a good safety profile. CSP reimplantation after extraction is also feasible with good electrical performance.image
引用
收藏
页码:2432 / 2443
页数:12
相关论文
共 50 条
  • [1] Transvenous lead extraction of lumenless 3830 pacing lead in conduction system pacing: a single-center experience
    Federico Migliore
    Raimondo Pittorru
    Manuel De Lazzari
    Vincenzo Tarzia
    Gianni Pastore
    Lina Marcantoni
    Domenico Catanzariti
    Gino Gerosa
    Francesco Zanon
    Journal of Interventional Cardiac Electrophysiology, 2024, 67 : 175 - 182
  • [2] Transvenous lead extraction of lumenless 3830 pacing lead in conduction system pacing: a single-center experience
    Migliore, Federico
    Pittorru, Raimondo
    De Lazzari, Manuel
    Tarzia, Vincenzo
    Pastore, Gianni
    Marcantoni, Lina
    Catanzariti, Domenico
    Gerosa, Gino
    Zanon, Francesco
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2024, 67 (01) : 175 - 182
  • [3] Stylet-driven Leads or Lumenless Leads for Conduction System Pacing
    Cano, Oscar
    De Pooter, Jan
    Zanon, Francesco
    ARRHYTHMIA & ELECTROPHYSIOLOGY REVIEW, 2024, 13
  • [4] Transvenous extraction of conduction system pacing leads: An international multicenter (TECSPAM) study
    Vijayaraman, Pugazhendhi
    Trivedi, Rohan S.
    Koneru, Jayanthi N.
    Sharma, Parikshit S.
    De Pooter, Jan
    Schaller, Robert D.
    Cano, Oscar
    Whinnett, Zachary I.
    Migliore, Federico
    Ponnusamy, Shunmuga Sundaram
    Skeete, Jamario R.
    Zanon, Francesco
    Heuverswyn, Frederic V.
    Kolominsky, Jeffrey
    Pittorru, Raimondo
    Mumtaz, Mishal
    Ellenbogen, Kenneth A.
    Herweg, Bengt
    HEART RHYTHM, 2024, 21 (10) : 1953 - 1961
  • [5] Transvenous lead extraction in conduction system pacing
    Wijesuriya, Nadeev
    Elliott, Mark K.
    Mehta, Vishal
    Behar, Jonathan M.
    Niederer, Steven
    Wilkoff, Bruce L.
    Rinaldi, Christopher A.
    FRONTIERS IN PHYSIOLOGY, 2022, 13
  • [6] EXTRACTION OF TRANSVENOUS PACING LEADS
    BYRD, CL
    AMERICAN HEART JOURNAL, 1992, 124 (06) : 1667 - 1668
  • [7] Extraction of transvenous pacing and ICD leads
    Smith, Macy C.
    Love, Charles J.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2008, 31 (06): : 736 - 752
  • [8] EXTRACTION OF TRANSVENOUS PACING LEADS - REPLY
    PARSONNET, V
    AMERICAN HEART JOURNAL, 1992, 124 (06) : 1668 - 1668
  • [9] Lumenless Pacing Leads: Performance and Extraction in Pediatrics and Congenital Heart Disease
    Garnreiter, Jason
    Whitaker, Patricia
    Pilcher, Thomas
    Etheridge, Susan
    Saarel, Elizabeth
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2015, 38 (01): : 42 - 47
  • [10] Percutaneous extraction of transvenous defibrillator leads using the VascoExtor pacing lead removal system
    Vassilikos, VP
    Maounis, TN
    Chiladakis, J
    Cokkinos, DV
    Manolis, AS
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 1999, 3 (03) : 247 - 251