ToF-SIMS Investigation of Environmental Effects on Analyte Migration in Matrix Coatings for Mass Spectrometry Imaging Using a Newly Developed Vapor Deposition System

被引:1
|
作者
Adolphs, Thorsten [1 ,2 ]
Baeumer, Michael [1 ,2 ]
Bosse, Florian [2 ,3 ]
Ravoo, Bart Jan [2 ,3 ]
Peterson, Richard E. [1 ]
Arlinghaus, Heinrich F. [1 ,2 ]
Tyler, Bonnie J. [1 ,2 ]
机构
[1] Univ Munster, Inst Phys, D-86159 Munster, Germany
[2] Univ Munster, D-48149 Munster, Germany
[3] Univ Munster, Organ Chem Inst, D-48149 Munster, Germany
关键词
SUBLIMATION; DEVICE;
D O I
10.1021/jasms.4c00340
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
High resolution mass spectrometry images are of increasing importance in biological applications, such as the study of tissues and single cells. Two promising techniques for this are matrix-enhanced secondary ion mass spectrometry (ME-SIMS) and matrix-assisted laser desorption/ionization (MALDI). For both techniques, the sample of interest must be coated with a matrix prior to analysis, and analytes must migrate into the matrix. The mechanisms involved in this migration and the factors that influence the migration are poorly understood, which lead to difficulties with reproducibility. In this work, a sublimation matrix coater with an effusion cell and sample cooling was developed and built in-house for controlled physical vapor deposition. In this system, sample transfer between the coater and mass spectrometer is possible without breaking vacuum, which facilitates the study of environmental influences on analyte migration. The influence of exposure to ambient air on the migration of two analytes (a lipid and a peptide), which were coated with the matrix alpha-cyano-4-hydroxycinnamic acid (CHCA), was studied using 3D-SIMS imaging. Although the distribution of analyte in the matrix changed very little after 21 h of storage in vacuum, significant redistribution of the analyte was observed after exposure to ambient air. The magnitude of the effect was greater for the lipid than for the peptide. Further work is needed to determine the role of humidity in the redistribution process and the impact of analyte redistribution on MALDI measurements.
引用
收藏
页码:3163 / 3169
页数:7
相关论文
共 22 条
  • [1] ToF-SIMS Investigation of Environmental Effects on Analyte Migration in Matrix Coatings for Mass Spectrometry Imaging Using a Newly Developed Vapor Deposition System
    Adolphs, Thorsten
    Baumer, Michael
    Bosse, Florian
    Ravoo, Bart Jan
    Peterson, Richard E.
    Arlinghaus, Heinrich F.
    Tyler, Bonnie J.
    Journal of the American Society for Mass Spectrometry, 2024,
  • [2] Freeze-etching and vapor matrix deposition for ToF-SIMS imaging of single cells
    Piehowski, Paul D.
    Kurczy, Michael E.
    Willingham, David
    Parry, Shawn
    Heien, Michael L.
    Winograd, Nicholas
    Ewing, Andrew G.
    LANGMUIR, 2008, 24 (15) : 7906 - 7911
  • [3] Preliminary studies using imaging mass spectrometry TOF-SIMS in detection and analysis of fingerprints
    Szynkowska, M. I.
    Czerski, K.
    Grams, J.
    Paryjczak, T.
    Parczewski, A.
    IMAGING SCIENCE JOURNAL, 2007, 55 (03): : 180 - 187
  • [4] ANYL 380-Matrix effects in biomolecular imaging using ToF-SIMS
    Vaidyanathan, Seetharaman
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2009, 238
  • [5] Investigation into the nature of historical tapestries using time of flight secondary ion mass spectrometry (ToF-SIMS)
    Batcheller, J.
    Hacke, A. M.
    Mitchell, R.
    Carr, C. M.
    APPLIED SURFACE SCIENCE, 2006, 252 (19) : 7113 - 7116
  • [6] Investigation of organic coatings and coating defects with the help of time-of-flight-secondary ion mass spectrometry (TOF-SIMS)
    Brenda, M
    Döring, R
    Schernau, U
    PROGRESS IN ORGANIC COATINGS, 1999, 35 (1-4) : 183 - 189
  • [7] Insights into the MALDI Process after Matrix Deposition by Sublimation Using 3D ToF-SIMS Imaging
    Van Nuffel, Sebastiaan
    Elie, Nicolas
    Yang, Ethan
    Nouet, Julius
    Touboul, David
    Chaurand, Pierre
    Brunelle, Alain
    ANALYTICAL CHEMISTRY, 2018, 90 (03) : 1907 - 1914
  • [8] Multimodal Imaging Mass Spectrometry to Identify Markers of Pulmonary Arterial Hypertension in Human Lung Tissue Using MALDI-ToF, ToF-SIMS, and Hybrid SIMS
    Van Nuffel, Sebastiaan
    Quatredeniers, Marceau
    Pirkl, Alexander
    Zakel, Julia
    Le Caer, Jean-Pierre
    Elie, Nicolas
    Vanbellingen, Quentin P.
    Dumas, Sebastien Joel
    Nakhleh, Morad Kamel
    Ghigna, Maria-Rosa
    Fadel, Elie
    Humbert, Marc
    Chaurand, Pierre
    Touboul, David
    Cohen-Kaminsky, Sylvia
    Brunelle, Alain
    ANALYTICAL CHEMISTRY, 2020, 92 (17) : 12079 - 12087
  • [9] Imaging and quantitative analysis of insecticide in mosquito net fibers using Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS)
    Smith, Stephen C.
    Zhou, Chuanzhen
    Stevie, Fred A.
    Garcia, Roberto
    PLOS ONE, 2018, 13 (12):
  • [10] Biomarker imaging of single diatom cells in a microbial mat using time-of-flight secondary ion mass spectrometry (ToF-SIMS)
    Leefmann, Tim
    Heim, Christine
    Kryvenda, Anastasiia
    Siljestrom, Sandra
    Sjovall, Peter
    Thiel, Volker
    ORGANIC GEOCHEMISTRY, 2013, 57 : 23 - 33