Sagittal accuracy and functional impact of tibial slope in imageless robotic-assisted Total Knee Arthroplasty

被引:0
|
作者
Eggermont, Erwan [1 ]
Janssens, Raphael [2 ]
Ulrix, Maarten [1 ]
Fils, Jean-Francois [3 ]
Hernigou, Jacques [4 ,5 ]
Everaert, Johnatan [1 ]
Baillon, Bruno [1 ,2 ]
机构
[1] Univ libre Bruxelles, Brussels, Belgium
[2] Iris South Hosp Grp, Dept Orthopaed Surg, Brussels, Belgium
[3] Ars Stat SRL, Nivelles, Belgium
[4] Ath Hosp, Orthopaed Dept, EPICURA Baudour, Nivelles, Hainaut, Belgium
[5] Univ Mons, Mons, Belgium
关键词
Posterior tibial slope; Robotic-assisted; Total knee arthroplasty; Sagittal accuracy; OKS; KOOS; ROBUST ESTIMATION; MECHANICAL AXIS; ALIGNMENT; ANGLE;
D O I
10.1007/s00264-025-06472-w
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
PurposeStudy of the sagittal accuracy of the 'Robotic Surgical Assistant' (ROSA (R)), compared to conventional surgery, regarding the application of the tibial slope (TS). Study of the impact of TS on the range of motion (ROM) and patient-reported outcome measures (PROMS).MethodsInclusion of patients who underwent primary Total Knee Arthroplasty (TKA) between 1/1/2021 and 15/4/2024. Divided into robotic-assisted TKA (RA-TKA) and manual TKA (M-TKA). Measurement of pre- and post-operative TS, using the posterior tibial cortex, on profile knee X-rays. 3 degrees TS applied arbitrarily for both groups. ROM was measured pre-operatively and at three, six and 12 months post-operatively. Patient satisfaction assessed via Knee Injury and Osteoarthritis Outcome Score (KOOS) and Oxford Knee Score (OKS).Results266 patients were included in the study. The M-TKA (110) had a post-operative TS of 3.11 degrees (+/- 2.12 degrees). 81.21% were within 2 degrees of the target and 92.87% within 3 degrees. The RA-TKA (82) had a post-operative TS of -0.11 degrees +/- (1.93 degrees). 36.83% were within 2 degrees of the target and 56.63% within 3 degrees. RA-TKA had a KOOS of 64.43 +/- 12.87 and OKS of 33.05 +/- 6.01. M-TKA had a KOOS of 64.18 +/- 13.11 and OKS of 32.31 +/- 5.97. Maximum flexion at 12 months was 118.74 degrees +/- 8.19 degrees for M-TKA and 121.88 degrees +/- 7.43 degrees for RA-TKA (p = 0.002).ConclusionThe application of TS using ROSA (R) was less precise than the conventional method in achieving post-operative TS values as measured on X-rays. However, there were no clinical differences in ROM or PROMS.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Versatility and accuracy of a novel image-free robotic-assisted system for total knee arthroplasty
    Singh, Vivek
    Teo, Greg M.
    Long, William J.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2021, 141 (12) : 2077 - 2086
  • [32] Surgical accuracy and clinical outcomes of image-free robotic-assisted total knee arthroplasty
    Lau, Cyrus Tsun-Kit
    Chau, Wai-Wang
    Lau, Lawrence Chun-Man
    Ho, Kevin Ki-Wai
    Ong, Michael Tim-Yun
    Yung, Patrick Shu-Hang
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2023, 19 (03):
  • [33] Simultaneous Evaluation of Bone Cut and Implant Placement Accuracy in Robotic-Assisted Total Knee Arthroplasty
    Cosendey, Killian
    Stanovici, Julien
    Cadas, Hugues
    Omoumi, Patrick
    Jolles, Brigitte M.
    Favre, Julien
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (05)
  • [34] Versatility and accuracy of a novel image-free robotic-assisted system for total knee arthroplasty
    Vivek Singh
    Greg M. Teo
    William J. Long
    Archives of Orthopaedic and Trauma Surgery, 2021, 141 : 2077 - 2086
  • [35] Imageless robotic handpiece-assisted total knee arthroplasty: a learning curve analysis of surgical time and alignment accuracy
    Savov, Peter
    Tuecking, Lars-Rene
    Windhagen, Henning
    Ehmig, Jonathan
    Ettinger, Max
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2021, 141 (12) : 2119 - 2128
  • [36] Imageless robotic handpiece-assisted total knee arthroplasty: a learning curve analysis of surgical time and alignment accuracy
    Peter Savov
    Lars-Rene Tuecking
    Henning Windhagen
    Jonathan Ehmig
    Max Ettinger
    Archives of Orthopaedic and Trauma Surgery, 2021, 141 : 2119 - 2128
  • [37] Robotic-assisted Unicompartmental Knee Arthroplasty
    Tamam, Cuneyt
    Poehling, Gary G.
    SPORTS MEDICINE AND ARTHROSCOPY REVIEW, 2014, 22 (04): : 219 - 222
  • [38] Imageless robotic-assisted total knee arthroplasty accurately restores the radiological alignment with a short learning curve: a randomized controlled trial
    Thiengwittayaporn, Satit
    Uthaitas, Pinyong
    Senwiruch, Chaipipathn
    Hongku, Natthapong
    Tunyasuwanakul, Revit
    INTERNATIONAL ORTHOPAEDICS, 2021, 45 (11) : 2851 - 2858
  • [39] Imageless robotic-assisted total knee arthroplasty accurately restores the radiological alignment with a short learning curve: a randomized controlled trial
    Satit Thiengwittayaporn
    Pinyong Uthaitas
    Chaipipathn Senwiruch
    Natthapong Hongku
    Revit Tunyasuwanakul
    International Orthopaedics, 2021, 45 : 2851 - 2858
  • [40] Improved Accuracy of Component Positioning with Robotic-Assisted Unicompartmental Knee Arthroplasty
    Bell, Stuart W.
    Anthony, Iain
    Jones, Bryn
    MacLean, Angus
    Rowe, Philip
    Blyth, Mark
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2016, 98 (08): : 627 - 635