Evaluation of non-invasive sensors for monitoring core temperature

被引:0
|
作者
Thomas, Shavin S. [1 ]
Flickinger, Katharyn L. [2 ]
Elmer, Jonathan [2 ,3 ,4 ]
Callaway, Clifton W. [2 ]
机构
[1] Univ Pittsburgh, Sch Med, Pittsburgh, PA USA
[2] Univ Pittsburgh, Sch Med, Dept Emergency Med, Iroquois Bldg,Suite 400A,3600 Forbes Ave, Pittsburgh, PA 15213 USA
[3] Univ Pittsburgh, Sch Med, Dept Crit Care Med, Pittsburgh, PA 15213 USA
[4] Univ Pittsburgh, Sch Med, Dept Neurol, Pittsburgh, PA 15213 USA
关键词
Monitoring; Temperature; Non-invasive; Cardiac arrest; AGREEMENT;
D O I
10.1007/s10877-025-01289-9
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
We evaluated the accuracy and precision of zero-heat flux (ZHF) and dual sensor (DS) non-invasive temperature probes in intensive care unit (ICU) patients undergoing hypothermic temperature control, hypothesizing that both devices would accurately estimate core temperature. In a single-center prospective cohort study, we enrolled 35 ICU patients and applied continuous, non-invasive ZHF and/or DS probes to the lateral forehead or anterior chest to collect 358 observations. Conditions potentially influencing temperature estimation were recorded. Using Bland-Altman analysis with multiple paired observations per individual, we compared the bias between non-invasive probes and direct core temperature measurements. Lin's concordance coefficient (LCC) was computed to quantify precision. The mean bias between the ZHF probe and invasive temperature was + 0.98 degrees C; for the DS probe, it was - 2.19 degrees C. In hypothermic patients, the ZHF probe's accuracy improved (bias + 0.28 degrees C, LCC 0.86), while the DS probe remained inaccurate (bias - 2.52 degrees C, LCC 0.07). Clinical confounders like vasoactive agents or temperature control devices did not consistently affect bias, accuracy, or precision. Neither the ZHF nor DS non-invasive probes provided sufficient accuracy or precision to guide clinical decisions in the ICU. These results contrast with previous studies reporting biases within +/- 0.5 degrees C. However, the ZHF probe showed promising limited deviation, especially in hypothermic patients.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] NON-INVASIVE CARDIOPULMONARY MONITORING
    SANFILIPPO, JA
    COHN, J
    GUPTE, P
    BARBATO, J
    FELDMAN, M
    DELGUERCIO, LRM
    SURGERY, 1981, 90 (02) : 313 - 318
  • [42] Non-invasive Monitoring of Hormones
    Rettenbacher, Sophie
    Vick, Mandi
    Palme, Rupert
    WIENER TIERARZTLICHE MONATSSCHRIFT, 2012, 99 : 2 - 2
  • [43] Non-invasive hemoglobin monitoring
    Joseph, Bellal
    Haider, Ansab
    Rhee, Peter
    INTERNATIONAL JOURNAL OF SURGERY, 2016, 33 : 254 - 257
  • [44] NON-INVASIVE ICP MONITORING
    Czosnyka, Marek
    JOURNAL OF NEUROTRAUMA, 2014, 31 (05) : A9 - A9
  • [45] Non-invasive glucose monitoring
    Arnold, MA
    CURRENT OPINION IN BIOTECHNOLOGY, 1996, 7 (01) : 46 - 49
  • [46] A non-invasive monitoring system
    Hancock, Christopher Paul
    Chaudhry, Sabih
    2007 EUROPEAN MICROWAVE CONFERENCE, VOLS 1-4, 2007, : 313 - 316
  • [47] Comparison of Invasive and Non-Invasive TDR Sensors Features for Moisture Evaluation of the Building Materials
    Suchorab, Zbigniew
    Garbacz, Monika
    Duda, Sylwia
    Barnat-Hunek, Danuta
    Majerek, Dariusz
    THERMOPHYSICS 2018, 2018, 1988
  • [48] NON-INVASIVE HEMODYNAMIC MONITORING
    PRYSROBERTS, C
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1983, 27 : 7 - 7
  • [49] Non-invasive monitoring of autophagy
    Ben Loos
    Andre du Toit
    Jan-Hendrik S. Hofmeyr
    Nature Biomedical Engineering, 2022, 6 : 1015 - 1016
  • [50] Non-invasive Cerebrovascular Monitoring
    Kashif, Faisal M.
    Heldt, Thomas
    Novak, Vera
    Czosnyka, Marek
    Verghese, George C.
    STROKE, 2010, 41 (04) : E237 - E237