Improving heat dissipation characteristics of concurrent flow through a novel mini- and micro-channel stacked double-layer heat sink

被引:0
|
作者
Ho, C. J. [1 ]
Liao, Jr-Wei [1 ]
Chen, Bo-Lin [2 ,3 ]
Rashidi, Saman [4 ]
Yan, Wei-Mon [2 ,3 ]
机构
[1] Natl Cheng Kung Univ, Dept Mech Engn, Tainan 70101, Taiwan
[2] Natl Taipei Univ Technol, Dept Energy & Refrigerating Air Conditioning Engn, Taipei 10608, Taiwan
[3] Natl Taipei Univ Technol, Res Ctr Energy Conservat New Generat Residential C, Taipei 10608, Taiwan
[4] Semnan Univ, Fac New Sci & Technol, Dept Energy, Semnan, Iran
关键词
Mini-and micro-channel stacked double-layer heat sink; Conjugate heat dissipation; Finite volume method; Energy efficiency; COOLING PERFORMANCE; NANOFLUIDS;
D O I
10.1016/j.applthermaleng.2025.126282
中图分类号
O414.1 [热力学];
学科分类号
摘要
In the practical applications, it is important to reduce the temperature gradient and pressure drop in mini- and micro-channel heat sinks. In the present investigation, the numerical study is conducted to provide a new design of the mini- and micro-channel stacked double-layer heat sink with the pure water as the coolant. The study discusses whether the mini- and micro-channel stacked double-layer heat sink can provide a higher heat dissipation effect than the single-layer micro-channel heat sink. The three-dimensional velocity field in the channel is calculated by the pseudo-vorticity-velocity method, and the finite volume method is used to discrete the mathematical formulas. The relevant parameters and their ranges in the numerical simulation are used as follows: the inlet temperature isT(in) = 34 degrees C; the single-layer channel's range of Reynolds number is 500 similar to 2000 (equivalent to the total flow 12.19 similar to 52.05 cm(3)/min), the heat fluxes imposed to bottom of the heat sink are 25, 50 and 75 W/cm(2), and the ratios of flow rate for the heat sink are 0.5, 1.0, 1.3, 2.0, 2.5, and 3.0. From the numerical simulation results, it is found that when mini- and micro-channel stacked double-layer heat sink uses pure water/pure water as the coolants, the pressure drop decreases by 87.74 % at the ratio of flow rate of 3.0, and when the ratio of flow rate is 0.5, and the total flow rate is 38.77 cm(3)/min, the overall heat transfer coefficient increases by 16.56 % compared with the single-layer heat sink. The figure of merit index ratio has a maximum value of 2.0795 when the total flow rate is Q(uc)+Q(lc)=Q(sl)= 52.05 cm(3)/min and the flow rate ratio is 3.0, and a minimum value of 1.4455 can be achieved when the total flow rate is Q(uc)+Q(lc)=Q(sl)= 12.19 cm(3)/min and the flow rate ratio is 0.5.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Heat transfer characteristics of two-phase flow in a double-layer microchannel heat sink
    El-dean, A. Salah
    Hassan, O.
    Shafey, H.M.
    International Communications in Heat and Mass Transfer, 2022, 132
  • [22] Heat transfer characteristics of water and APG surfactant solution in a micro-channel heat sink
    Klein, D
    Hetsroni, G
    Mosyak, A
    INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2005, 31 (04) : 393 - 415
  • [23] Continuous nanofluids jet impingement heat transfer and flow in a micro-channel heat sink
    Naphon, P.
    Nakharintr, L.
    Wiriyasart, S.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 126 : 924 - 932
  • [24] A numerical and experimental investigation of flow maldistribution in a micro-channel heat sink
    Kumaraguruparan, G.
    Kumaran, R. Manikanda
    Sornakumar, T.
    Sundararajan, T.
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2011, 38 (10) : 1349 - 1353
  • [25] Thermal Characteristics of Staggered Double-Layer Microchannel Heat Sink
    Jing, Dalei
    He, Lei
    ENTROPY, 2018, 20 (07):
  • [26] HYBRID MINI/MICRO-CHANNEL HEAT SINK USING LIQUID METAL AND WATER AS COOLANTS
    Mei, Sheng-Fu
    Deng, Zhong-Shan
    Liu, Jing
    INTERNATIONAL TECHNICAL CONFERENCE AND EXHIBITION ON PACKAGING AND INTEGRATION OF ELECTRONIC AND PHOTONIC MICROSYSTEMS, 2015, VOL 2, 2015,
  • [27] The developing heat transfer and fluid flow in micro-channel heat sink with viscous heating effect
    Dorin Lelea
    Adrian Eugen Cioabla
    Heat and Mass Transfer, 2011, 47 : 751 - 758
  • [28] A CFD technique to investigate the chocked flow and heat transfer characteristic in a micro-channel heat sink
    Azari, Ahmad
    Bahraini, Abdorrasoul
    Marhamati, Saeideh
    INTERNATIONAL JOURNAL OF COMPUTATIONAL MATERIALS SCIENCE AND ENGINEERING, 2015, 4 (02)
  • [29] The developing heat transfer and fluid flow in micro-channel heat sink with viscous heating effect
    Lelea, Dorin
    Cioabla, Adrian Eugen
    HEAT AND MASS TRANSFER, 2011, 47 (07) : 751 - 758
  • [30] ANN, numerical and experimental analysis on the jet impingement nanofluids flow and heat transfer characteristics in the micro-channel heat sink
    Naphon, P.
    Wiriyasart, S.
    Arisariyawong, T.
    Nakharintr, L.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2019, 131 : 329 - 340