Objective. Previous work has that deep learning (DL)-enhanced 4D cone beam computed tomography (4D-CBCT) images improve motion modeling and subsequent motion-compensated (MoCo) reconstruction for 4D-CBCT. However, building the motion model at treatment time via conventional deformable image registration (DIR) methods is not temporally feasible. This work aims to improve the efficiency of 4D-CBCT MoCo reconstruction using DL-based registration for the rapid generation of a motion model prior to treatment. Approach. An artifact-reduction DL model was first used to improve the initial 4D-CBCT reconstruction by reducing streaking artifacts. Based on the artifact-reduced phase images, a groupwise DIR employing DL was used to estimate the inter-phase motion model. Two DL DIR models using different learning strategies were employed: (1) a patient-specific one-shot DIR model which was trained from scratch only using the images to be registered, and (2) a population DIR model which was pre-trained using collected 4D-CT images from 35 patients. The registration accuracy of two DL DIR models was assessed and compared to a conventional groupwise DIR approach implemented in the Elastix toolbox using the publicly available DIR-Lab dataset, a Monte Carlo simulation dataset from the SPARE challenge, and two clinical cases. Main results. The patient-specific DIR model and the population DIR model demonstrated registration accuracy comparable to the conventional state-of-the-art methods on the DIR-Lab dataset. No significant difference in image quality was observed between the final MoCo reconstructions using the patient-specific model and population model for motion modeling, compared to using the conventional approach. The average runtime (hh:mm:ss) of the entire MoCo reconstruction on SPARE dataset was reduced from 01:37:26 using conventional DIR method to 00:10:59 using patient-specific model and 00:01:05 using the pre-trained population model. Significance. DL-based registration methods can improve the efficiency in generating motion models for 4D-CBCT without compromising the performance of final MoCo reconstruction.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Geometric and Dosimetric Evaluation of a 4D-CBCT Reconstruction Technique Using Prior Knowledge
    Zhang, Y.
    Yin, F.
    Ren, L.
    MEDICAL PHYSICS, 2014, 41 (06) : 116 - 117
  • [42] Fast Groupwise 4D Deformable Image Registration for Irregular Breathing Motion Estimation
    Papiez, Bartlomiej W.
    McGowan, Daniel R.
    Skwarski, Michael
    Higgins, Geoff S.
    Schnabel, Julia A.
    Brady, Sir Michael
    BIOMEDICAL IMAGE REGISTRATION, WBIR 2018, 2018, 10883 : 37 - 46
  • [43] Advanced 4-dimensional cone-beam computed tomography reconstruction by combining motion estimation, motion-compensated reconstruction, biomechanical modeling and deep learning
    Zhang, You
    Huang, Xiaokun
    Wang, Jing
    VISUAL COMPUTING FOR INDUSTRY BIOMEDICINE AND ART, 2019, 2 (01)
  • [44] Advanced 4-dimensional cone-beam computed tomography reconstruction by combining motion estimation, motion-compensated reconstruction, biomechanical modeling and deep learning
    You Zhang
    Xiaokun Huang
    Jing Wang
    Visual Computing for Industry, Biomedicine, and Art, 2
  • [45] Suppressing Motion Related Artifacts in 4D-CT Or 4D-CBCT Reconstruction Using Projections and Digitally Reconstructed Projections: Proof of Principle
    Yi, B.
    Lasio, G.
    Liu, Y.
    Yu, C.
    Mistry, N.
    MEDICAL PHYSICS, 2014, 41 (06) : 194 - +
  • [46] Using 4D-CBCT for Lung Cancer SBRT Patients to Detect Tumor Motion Variations
    Yurtsever, C.
    Zhuang, T.
    Qi, P.
    Videtic, G. M.
    Stephans, K. L.
    Xia, P.
    Balik, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E363 - E364
  • [47] 3D Reconstruction for Motion Blurred Images Using Deep Learning-Based Intelligent Systems
    Zhang, Jing
    Yu, Keping
    Wen, Zheng
    Qi, Xin
    Paul, Anup Kumar
    CMC-COMPUTERS MATERIALS & CONTINUA, 2021, 66 (02): : 2087 - 2104
  • [48] Transfer-learning is a key ingredient to fast deep learning-based 4D liver MRI reconstruction
    Gino Gulamhussene
    Marko Rak
    Oleksii Bashkanov
    Fabian Joeres
    Jazan Omari
    Maciej Pech
    Christian Hansen
    Scientific Reports, 13
  • [49] Transfer-learning is a key ingredient to fast deep learning-based 4D liver MRI reconstruction
    Gulamhussene, Gino
    Rak, Marko
    Bashkanov, Oleksii
    Joeres, Fabian
    Omari, Jazan
    Pech, Maciej
    Hansen, Christian
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [50] Spatiotemporal structure-aware dictionary learning-based 4D CBCT reconstruction
    Zhi, Shaohua
    Kachelriess, Marc
    Mou, Xuanqin
    MEDICAL PHYSICS, 2021, 48 (10) : 6421 - 6436