Development of a GAGG gamma camera for the imaging of prompt gammas during proton beam irradiation

被引:0
|
作者
Yamamoto, Seiichi [1 ]
Yamashita, Tomohiro [2 ]
Kobashi, Yusuke [2 ]
Yabe, Takuya [3 ]
Nakanishi, Kohei [4 ]
Akagi, Takashi [5 ]
Yamaguchi, Mitsutaka [3 ]
Kawachi, Naoki [3 ]
Kamada, Kei [6 ]
Yoshikawa, Akira [6 ]
Kataoka, Jun [1 ]
机构
[1] Waseda Univ, Fac Sci & Engn, Tokyo, Japan
[2] Kobe Proton Ctr, Kobe, Japan
[3] Natl Inst Quantum Sci & Technol QST, Takasaki Inst Adv Quantum Sci, Chiba, Japan
[4] Nagoya Univ, Grad Sch Med, Nagoya, Japan
[5] Hyogo Ion Beam Med Ctr, Tatsuno, Japan
[6] Tohoku Univ, New Ind Creat Hatchery Ctr NICHe, Sendai, Japan
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2024年 / 127卷
关键词
Proton; Gamma camera; PGs; Range; PXs; POSITRON-EMISSION-TOMOGRAPHY; RANGE VERIFICATION; PET SYSTEM; DELIVERY;
D O I
10.1016/j.ejmp.2024.104847
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Prompt gammas imaging (PGI) is a promising method for observing a beam's shape and estimating the range of the beam from outside a subject. However 2-dimensional images of prompt gammas (PGs) during irradiation of protons were still difficult to measure. To achieve PGI, we developed a new gamma camera and imaged PGs while irradiating a phantom by proton beams. We also simultaneously measured prompt X-ray (PX) images with an X-ray camera from opposed direction and compared the images. The developed gamma camera uses a 10 mm thick GAGG block optically coupled to a flat panel photomultiplier tube (FP-PMT), and it is contained in a 20 mm thick tungsten container with a pinhole collimator attached. A poly-methyl-methacrylate (PMMA) block was irradiated by proton beams with total number of the protons similar to the clinical level, and the gamma camera imaged PGs and X-ray camera imaged PXs simultaneously. For all of the tested beams, we could measure the beam shapes of the PGs and the PXs and the ranges could also be estimated from the images. For both PG and PX images, time sequential images and accumulated images could be derived. We confirmed that the PGI using our developed gamma camera, as well as PXI, is promising for beam imaging and range estimation in proton therapy.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Simulation and experimental verification of prompt gamma-ray emissions during proton irradiation
    Schumann, A.
    Petzoldt, J.
    Dendooven, P.
    Enghardt, W.
    Golnik, C.
    Hueso-Gonzalez, F.
    Kormoll, T.
    Pausch, G.
    Roemer, K.
    Fiedler, F.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (10): : 4197 - 4207
  • [32] Measurement and calculation of characteristic prompt gamma ray spectra emitted during proton irradiation
    Polf, J. C.
    Peterson, S.
    McCleskey, M.
    Roeder, B. T.
    Spiridon, A.
    Beddar, S.
    Trache, L.
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (22): : N519 - N527
  • [33] Hybrid imaging of prompt x-rays and induced positrons using a pinhole gamma camera during and after irradiation of protons
    Yamamoto, Seiichi
    Watabe, Hiroshi
    Nakanishi, Kohei
    Yabe, Takuya
    Yamaguchi, Mitsutaka
    Kawachi, Naoki
    Kamada, Kei
    Yoshikawa, Akira
    Islam, Md Rafiqul
    Miyake, Masayasu
    Tanaka, Kazuo S.
    Kataoka, Jun
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (11):
  • [34] Verification for Prompt Gamma Ray Imaging During Proton Boron Fusion Therapy
    Shin, H.
    Yoon, D.
    Jung, J.
    Kim, M.
    Jang, H.
    Suh, T.
    MEDICAL PHYSICS, 2015, 42 (06) : 3583 - 3583
  • [35] Simultaneous imaging of prompt gamma photons and prompt X-rays during irradiation of proton beams to human torso phantom at clinical dose level
    Yamamoto, Seiichi
    Yamashita, Tomohiro
    Kobashi, Yusuke
    Yabe, Takuya
    Akagi, Takashi
    Yamaguchi, Mitsutaka
    Kawachi, Naoki
    Kamada, Kei
    Yoshikawa, Akira
    Yokokawa, Hiromu
    Sagisaka, Mayu
    Kataoka, Jun
    JOURNAL OF INSTRUMENTATION, 2023, 18 (07)
  • [36] Characterization of in-beam MR imaging performance during proton beam irradiation
    Hoffmann, A.
    Gantz, S.
    Grossinger, P.
    Karsch, L.
    Pawelke, J.
    Serra, A.
    Smeets, J.
    Schellhammer, S.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S547 - S548
  • [37] Determination of Optimal Energy Window for Measurement of Prompt Gammas from Proton Beam by Monte Carlo Simulations
    Min, Chul Hee
    Park, Jang Guen
    An, So Hyun
    Kim, Chan Hyeong
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2008, : 28 - 31
  • [38] REAL-TIME PROTON BEAM RANGE MONITORING BY MEANS OF PROMPT-GAMMA DETECTION WITH A COLLIMATED CAMERA
    Roellinghoff, F.
    Benilov, A.
    Dauvergne, D.
    Dedes, G.
    Freud, N.
    Krimmer, J.
    Letang, J. M.
    Prieels, D.
    Ray, C.
    Richard, M. H.
    Smeets, J.
    Stichelbaut, F.
    Testa, E.
    RADIOTHERAPY AND ONCOLOGY, 2012, 102 : S120 - S121
  • [39] Real-time proton beam range monitoring by means of prompt-gamma detection with a collimated camera
    Roellinghoff, F.
    Benilov, A.
    Dauvergne, D.
    Dedes, G.
    Freud, N.
    Janssens, G.
    Krimmer, J.
    Letang, J. M.
    Pinto, M.
    Prieels, D.
    Ray, C.
    Smeets, J.
    Stichelbaut, F.
    Testa, E.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (05): : 1327 - 1338
  • [40] Comment on 'Imaging of prompt gamma rays emitted during delivery of clinical proton beams with a Compton camera: feasibility studies for range verification'
    Sitek, Arkadiusz
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (24): : 8941 - 8944