Load reduction by a demand response enhanced chilled water distributor for centralized air-conditioning systems in commercial building

被引:0
|
作者
Yan, Xiuying [1 ,2 ]
Wu, Xiaoxue [2 ]
Ji, Xingxing [2 ]
Meng, Qinglong [3 ]
机构
[1] Xian Univ Architecture & Technol, State Key Lab Green Bldg, Xian 710055, Peoples R China
[2] Xian Univ Architecture & Technol, Sch Bldg Serv Sci & Engn, Xian 710055, Peoples R China
[3] Changan Univ, Sch Civil Engn, Xian 710061, Peoples R China
关键词
Load reduction; Centralized air conditioning system; Cooling load prediction; Demand response; Thermal comfort; CONTROL STRATEGY; THERMAL COMFORT; URGENT REQUESTS; MODEL;
D O I
10.1016/j.enbuild.2025.115580
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In response to the increasing energy demands and environmental concerns, strategies for managing peak electricity load in commercial buildings are becoming challenges. A demand response (DR) control strategy based on load prediction is proposed to alleviate the pressure on the grid caused by peak demand while ensuring good building environment and meeting thermal comfort for users. The strategy implements partial chiller shutdown with pre-cooling. An enhanced chilled water distributor considering personnel satisfaction, which adds a factor for the sensitivity of indoor air temperature increases in the adaptive function, is proposed. A co-simulation platform was developed to investigate load shifting potential, enhance energy efficiency and reduce operating costs. Thermal comfort is also considered, ensuring the long-term effectiveness of the strategy and user satisfaction. It is compared with conventional control strategy, price-based DR strategy, partial chiller shutdown, as well as DR control strategies involving partial chiller shutdown and pre-cooling. The simulation results demonstrate that the proposed DR strategy achieved the maximum load reduction without causing load rebound. The proposed DR strategy achieves a 4.7% electricity saving rate and a 3.5% reduction in total operating costs comparing to partial chiller shutdown. The indoor temperature and temperature deviation are controlled in reasonable ranges.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Evaluation of commercial building demand response potential using optimal short-term curtailment of heating, ventilation, and air-conditioning loads
    Olivieri, Simon J.
    Henze, Gregor P.
    Corbin, Chad D.
    Brandemuehl, Michael J.
    JOURNAL OF BUILDING PERFORMANCE SIMULATION, 2014, 7 (02) : 100 - 118
  • [32] Optimal classification of radiant time series for cooling load calculation of building air-conditioning systems
    Ren, Jing
    Chen, Youming
    Zhang, Xinchao
    Liu, Jiaming
    ENERGY AND BUILDINGS, 2024, 320
  • [33] Estimated Thermal Load and Selecting of Suitable Air-Conditioning Systems for a Three Story Educational Building
    Sait, Hani H.
    4TH INTERNATIONAL CONFERENCE ON AMBIENT SYSTEMS, NETWORKS AND TECHNOLOGIES (ANT 2013), THE 3RD INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY INFORMATION TECHNOLOGY (SEIT-2013), 2013, 19 : 636 - 645
  • [34] A bilayer interaction strategy for air-conditioning load aggregators considering market-based demand response
    Zhu, Yuchao
    Wang, Jianxue
    Tian, Dongmeng
    Sung, Chunxiao
    JOURNAL OF ENGINEERING-JOE, 2019, (16): : 1241 - 1246
  • [35] A User-centric Demand Response Framework for Residential Heating, Ventilation, and Air-conditioning Load Management
    Ali, Mubbashir
    Jokisalo, Juha
    Siren, Kai
    Safdarian, Amir
    Lehtonen, Matti
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2016, 44 (01) : 99 - 109
  • [36] Trusted Interconnections Between a Centralized Controller and Commercial Building HVAC Systems for Reliable Demand Response
    Jones, C. Birk
    Carter, Cedric, Jr.
    IEEE ACCESS, 2017, 5 : 11063 - 11073
  • [37] A Load Restoration Amount Reduction Method Considering Demand Response of Air Conditioning Loads
    Fan, Rui
    Sun, Runjia
    Liu, Yutian
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2022, 37 (11): : 2869 - 2877
  • [38] The Power Simulation of Water-Cooled Central Air-Conditioning System Based on Demand Response
    Kang, Ligai
    Wang, Gang
    Wang, Yongzhen
    An, Qingsong
    IEEE ACCESS, 2020, 8 : 67396 - 67407
  • [39] Modelling and mitigating lifetime impact of building demand responsive control of heating, ventilation and air-conditioning systems
    Sanchez, Jerson
    Jiang, Zhimin
    Cai, Jie
    JOURNAL OF BUILDING PERFORMANCE SIMULATION, 2022, 15 (06) : 771 - 787
  • [40] A Potential Analysis on Regional Demand Response by Air-conditioning Systems Combined with Gas Engine Cogeneration
    Abe, Ryo
    Tomofuji, Daisuke
    Ikegami, Takashi
    Akisawa, Atsushi
    JOURNAL OF THE JAPAN INSTITUTE OF ENERGY, 2021, 100 (11) : 263 - 272