Investigating stress corrosion-induced rupture behavior using the acoustic emission technique

被引:0
|
作者
Wang, Fei [1 ,2 ]
He, Zhi Liang [1 ,4 ]
Deng, Jian Hui [1 ]
Chen, Fei [3 ]
Verstrynge, Els [2 ]
机构
[1] Sichuan Univ, Coll Water Resources & Hydropower, Chengdu 610065, Peoples R China
[2] Katholieke Univ Leuven, Civil Engn Dept, Mat & Construct Div, B-3000 Leuven, Belgium
[3] Chengdu Univ, Sch Architecture & Civil Engn, Chengdu 610106, Peoples R China
[4] Southwest Univ Sci & Technol, Sch Environm & Resources, Mianyang 621010, Peoples R China
基金
中国国家自然科学基金;
关键词
Rock failure; Rock-water interaction; Stress corrosion; Acoustic emission; Damage evolution; SUBCRITICAL CRACK-PROPAGATION; TIME-DEPENDENT DEFORMATION; ISRM-SUGGESTED METHOD; MECHANICAL-PROPERTIES; COMPRESSIVE STRENGTH; FRACTURE-MECHANICS; WATER; MODE; ROCK; GROWTH;
D O I
10.1016/j.tafmec.2025.104843
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The rupture behavior of rocks in water environments is influenced by complex rock-water interactions, with stress corrosion recognized as a significant factor. However, the effect of stress corrosion on rock rupture is often masked by concurrent rock-water interaction mechanisms, complicating its isolated analysis. In this study, fused quartz glass samples were used to eliminate extraneous factors, enabling a dedicated investigation of the stress corrosion-induced rupture under controlled fracture modes and water conditions. Semi-circular bending tests in a water-based environment were conducted, with fracture processes monitored using the acoustic emission (AE) technique. Loading curves, rupture paths, and surface morphologies were analyzed to reveal macroscale fracture features. AE parameter analysis, source localization, and moment tensor inversion were employed to investigate spatiotemporal damage evolution at the mesoscale. The stress corrosion-induced failure exhibits interesting softening fracture behavior at both the mesoscale and macroscale. At the macroscale, softening deformation is induced by stress corrosion, with energy release at the crack tip occurring gently. At the mesoscale, meso-crack proliferation can be triggered by stress corrosion, leading to a cross-scale damage evolution process. The damage process exhibits distinct instability characteristics at 50-80 % load levels under mode I fracture, whereas it remains relatively stable under mode II fracture. As peak stress approaches, the proliferation of mesoscale fractures forms an irreversible crack network that alters the local mesostructure, governing failure behavior and facilitating macroscale softening rupture. It is found that the flowing water and tensile fracture mode stimulate corrosion and intensify degradation, which deserves heightened concern in engineering.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] On corrosion-induced stress states in binary noble metal alloys
    Mon, K
    Ferrari, M
    MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 1997, 232 (1-2): : 88 - 102
  • [22] Metal corrosion monitoring with acoustic emission technique
    Li, B.Y.
    Zhang, W.
    Materials Research Innovations, 2015, 19 : 873 - 876
  • [23] Monitoring corrosion-induced thickness loss of stainless steel plates using the electromechanical impedance technique
    Liu, Yang
    Feng, Xin
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2021, 32 (02)
  • [24] Hydrogen-induced degradation behavior of nickel alloy studied using acoustic emission technique
    Soundararajan, Chandrahaasan K.
    Myhre, Aleksander
    Sendrowicz, Aleksander
    Lu, Xu
    Vinogradov, Alexey
    MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 2023, 865
  • [25] USING ACOUSTIC-EMISSION TO MONITOR STRESS-CORROSION CRACKING
    JONES, RH
    FRIESEL, MA
    JOM-JOURNAL OF THE MINERALS METALS & MATERIALS SOCIETY, 1990, 42 (12): : 12 - 15
  • [26] Stress corrosion damage evolution analysis and mechanism identification for prestressed steel strands using acoustic emission technique
    Li, Dongsheng
    Tan, Meiling
    Zhang, Shuaifang
    Ou, Jinping
    STRUCTURAL CONTROL & HEALTH MONITORING, 2018, 25 (08):
  • [27] Investigating corrosion-induced deterioration in bolted steel plate joints using guided wave ultrasonic inspection
    Shah, Jay Kumar
    Majhi, Subhra
    Mukherjee, Abhijit
    Wang, Hao
    JOURNAL OF CIVIL STRUCTURAL HEALTH MONITORING, 2025, 15 (03) : 745 - 758
  • [28] Corrosion inspection method of steam generator tubes using acoustic emission technique
    Hou, S.
    Luo, J.
    Shen, T.
    Xu, J.
    MATERIALS RESEARCH INNOVATIONS, 2015, 19 : 1237 - 1240
  • [29] Fatigue of the bond behavior of corroded reinforced concrete with corrosion-induced cracks
    Lin H.-W.
    Zhao Y.-X.
    Guo C.-X.
    Hu L.
    Feng P.
    Lin, Hong-Wei (hwlinccea@zju.edu.cn), 1600, Tsinghua University (37): : 98 - 107
  • [30] Effect of corrosion-induced crack and corroded rebar shape on bond behavior
    Yang, Yizhou
    Nakamura, Hikaru
    Miura, Taito
    Yamamoto, Yoshihito