Electrochemical detection of alpha-fetoprotein using graphene-assisted sensors: A novel approach for liver cancer screening
被引:0
|作者:
Cui, Chuanbao
[1
,2
]
Xu, Ming
[3
]
Guan, Qinglong
[4
]
Wang, Xuejian
[5
]
Yang, Guangcheng
[1
]
Zhang, Zhen
[2
]
Du, Jingjing
[6
]
机构:
[1] Taishan Univ, Sch Biol & Brewing Engn, Tai An 271000, Peoples R China
[2] Shandong Univ Tradit Chinese Med, Innovat Res Inst Tradit Chinese Med, Jinan 250355, Peoples R China
[3] Qilu Med Univ, Sch Basic Med Sci, Dept Histol & Embryol, Zibo 255300, Peoples R China
[4] Shandong First Med Univ, Affiliated Hosp 2, Dept Vasc Surg, Tai An 271000, Peoples R China
[5] Shandong Second Med Univ, Sch Pharm, Weifang, Shandong, Peoples R China
[6] Jinzhou Med Univ, Grad Sch, Jinzhou 121000, Liaoning, Peoples R China
关键词:
Immunosensor;
Nanocomposite;
Biomarker;
Hepatocellular carcinoma;
Point-of-care diagnostics;
IONIC LIQUID;
IMMUNOSENSOR;
COMPOSITE;
DEGRADATION;
ELECTRODE;
CATALYST;
PARTICLE;
AFP;
D O I:
10.1016/j.aej.2025.03.052
中图分类号:
T [工业技术];
学科分类号:
08 ;
摘要:
This study presents a novel electrochemical immunosensor for the detection of alpha-fetoprotein (AFP) based on a toluidine blue-gold-Fe3O4-reduced graphene oxide (TB-Au-Fe3O4-rGO) nanocomposite. The multifunctionalized graphene platform was synthesized and characterized using SEM, TEM, XRD, and FTIR spectroscopy. Electrochemical characterization revealed enhanced electron transfer kinetics, with the TB-Au-Fe3O4rGO electrode exhibiting the lowest charge transfer resistance of 43 Omega. Optimization of antibody immobilization and assay conditions resulted in a sensitive and selective immunosensor. The sensor showed a direct correlation with AFP levels ranging from 0.1 to 500 ng/mL, and was able to detect concentrations as low as 0.03 ng/mL. Selectivity studies showed minimal interference from common serum proteins, even at 100-fold higher concentrations. The immunosensor showed consistent results with a relative standard deviation of 3.8 % from 5 replicates, and retained more than 95 % of its original signal after being stored at 4 degrees C for 30 days. Analysis of clinical serum samples showed excellent agreement with ELISA results (R2 = 0.998) and recovery rates between 96.5 % and 103.8 % for spiked samples. The rapid response time of 35 seconds and simple operation make this platform promising for point-of-care liver cancer screening. This work demonstrates the potential of multifunctionalized graphene nanocomposites for enhancing the performance of electrochemical immunosensors in clinical diagnostics.
引用
收藏
页码:511 / 518
页数:8