Numerical investigation on air-side heat transfer enhancement of wavy finned tube air cooler for underground tunnels

被引:0
|
作者
Wang, Yangjie [1 ]
Cai, Tianqi [1 ]
Niu, Pengxiang [2 ]
Fan, Wenbo [2 ]
Wang, Yijiang [1 ]
机构
[1] China Univ Min & Technol, Sch Mech & Civil Engn, State Key Lab Intelligent Construct & Hlth Operat, Xuzhou 221116, Peoples R China
[2] China Coal Construct Grp Corp Ltd, Beijing 102218, Peoples R China
基金
中国国家自然科学基金;
关键词
Wavy finned tube air cooler; Heat transfer enhancement; Vortex generator; Slit perforation; Thermal-hydraulic performance; THERMAL-HYDRAULIC PERFORMANCE; WINGLET VORTEX GENERATORS; FIELD SYNERGY PRINCIPLE; FRICTION CHARACTERISTICS; FLUID-FLOW; LONGITUDINAL VORTICES; DELTA WINGLETS; CROSS-FLOW; PLAIN FIN; EXCHANGERS;
D O I
10.1016/j.applthermaleng.2025.126061
中图分类号
O414.1 [热力学];
学科分类号
摘要
Air coolers used in underground tunnels are traditionally bare tube units with limited thermal performance, negatively impacting refrigeration systems' energy efficiency. To enhance heat transfer efficiency, this study explores the application of finned-tube air coolers in underground tunnels or shafts with low dust concentrations during construction. The potential of wavy finned-tube air coolers to improve thermal performance under high wind speed conditions is investigated using numerical simulations. The RNG k-epsilon model was used to numerically investigate the effects of fin and finned tube design parameters, delta-wing vortex generator (VG-D) and slit configurations on the thermal-hydraulic performance of wavy finned tube air cooler. Key performance indicators, including the Nusselt number (Nu), friction factor (f), fin efficiency and composite performance factor (JF) are utilized to assess the enhancements. The results demonstrate that augmenting the height and thickness of wavy fins and the longitudinal tube pitch leads to improvements in both Nu and f. Reducing the transverse tube pitch enhances the Nu, fin efficiency and JF. Moreover, the integration of VG-D boosts Nu by 10.1% and JF by 7.3% compared to the base design. The addition of top-bottom slit perforations further augments the Nu and fin efficiency by 10.3%, 4.9%, and reduces the JF by 2.9%. Empirical correlations for the air-side performance of wavy finned-tube air coolers are also proposed, with deviation error less than 15%. These results can offer valuable insights for the design of high-efficiency wavy finned air coolers specifically suited for underground tunnel applications.
引用
收藏
页数:20
相关论文
共 50 条
  • [31] Effect of fin pattern on the air-side performance of herringbone wavy fin-and-tube heat exchangers
    Chokeman, Y
    Wongwises, S
    HEAT AND MASS TRANSFER, 2005, 41 (07) : 642 - 650
  • [32] Effect of fin thickness on air-side performance of herringbone wavy fin-and-tube heat exchangers
    Somchai Wongwises
    Yutasak Chokeman
    Heat and Mass Transfer, 2004, 41 : 147 - 154
  • [33] Effect of fin thickness on air-side performance of herringbone wavy fin-and-tube heat exchangers
    Wongwises, S
    Chokeman, Y
    HEAT AND MASS TRANSFER, 2004, 41 (02) : 147 - 154
  • [34] SIGNIFICANCE OF DELTA WINGLETS ON THE AIR SIDE PERFORMANCE OF FLAT FINNED VERSUS WAVY FINNED-TUBE HEAT EXCHANGERS
    Khan, Tariq Amin
    Gardezi, Nasir Mehdi
    Li, Wei
    Zhou, Yang
    Ayub, Zahid
    PROCEEDINGS OF THE ASME 2020 HEAT TRANSFER SUMMER CONFERENCE (HT2020), 2020,
  • [35] Effect of fin pattern on the air-side performance of herringbone wavy fin-and-tube heat exchangers
    Yutasak Chokeman
    Somchai Wongwises
    Heat and Mass Transfer, 2005, 41 : 642 - 650
  • [36] Advancements in analyzing air-side heat transfer coefficient on the individual tube rows in finned heat exchangers: Comparative study of three CFD methods
    Marcinkowski, Mateusz
    Taler, Dawid
    Weglarz, Katarzyna
    Taler, Jan
    ENERGY, 2024, 307
  • [37] Experimental and numerical investigation on air-side performance of fin-and-tube heat exchangers with various fin patterns
    Tang, L. H.
    Zeng, M.
    Wang, Q. W.
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2009, 33 (05) : 818 - 827
  • [38] Air-side heat transfer characteristics of flat plate finned-tube heat exchangers with large fin pitches under frosting conditions
    Lee, Mooyeon
    Kim, Yonghan
    Lee, Hosung
    Kim, Yongchan
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2010, 53 (13-14) : 2655 - 2661
  • [39] A Correlation for the Air-Side Heat Transfer Coefficient Assessment in Continuous Flat-Plate Finned Heat Exchangers
    Tarrad, Ali Hussain
    Khudor, Damiaa Saad
    JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2015, 7 (02)
  • [40] AIR-SIDE HEAT TRANSFER ENHANCEMENT AND PUMPING POWER PENALTY IN AIR-COOLED HEAT EXCHANGERS WITH DIMPLED FINS
    Vu, Tung X.
    Mohanta, Lokanath
    Dhir, Vijay K.
    PROCEEDINGS OF THE ASME SUMMER HEAT TRANSFER CONFERENCE, 2017, VOL 1, 2017,