Bearing and tearout of austenitic and duplex stainless steel bolted connections

被引:2
|
作者
Song, Yuchen [1 ]
Lin, Xue-Mei [2 ]
Yam, Michael C. H. [1 ,3 ]
Zhang, Yuelin [1 ,4 ]
Ke, Ke [5 ]
Wang, Jia [6 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg & Real Estate, Hong Kong, Peoples R China
[2] Univ Dundee, Sch Sci & Engn, Dundee, Scotland
[3] Hong Kong Polytech Univ, Chinese Natl Engn Res Ctr Steel Construct, Hong Kong Branch, Hong Kong, Peoples R China
[4] Tongji Univ, Dept Struct Engn, Shanghai, Peoples R China
[5] Chongqing Univ, Sch Civil Engn, Chongqing, Peoples R China
[6] Southeast Univ, Sch Transportat, Nanjing, Peoples R China
基金
中国国家自然科学基金;
关键词
Austenitic stainless steel; Duplex stainless steel; Bolted connections; Tearout; Bearing; Design; STRUCTURAL BEHAVIOR;
D O I
10.1016/j.tws.2024.112585
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Due to the unique material characteristics of stainless steel, the bearing and tearout behaviour of stainless steel bolted connections can be different from that of carbon steel bolted connections. Such difference has been gradually recognised in recent design provisions for stainless steel structures. However, it is noteworthy that the existing design methods were mainly developed for austenitic and ferritic stainless steel bolted connections. Their applicability to duplex stainless steel bolted connections is questionable. Moreover, comparing to the bearing failure of stainless steel connections, less attention has been paid to the tearout failure, as well as the combined bearing and tearout failure in multi-bolt connections. To fill these gaps, an experimental and numerical study is carried out on the bearing/tearout behaviour and design of stainless steel bolted connections. The experimental programme includes 22 connection specimens with either single-bolt or multi-bolt configurations, made of austenitic or duplex stainless steel. The experimental tests are supplemented by a comprehensive numerical parametric study with >200 individual models, performed based on a validated finite element modelling technique. The obtained test and numerical results are used to assess the effects of different design parameters, as well as the applicability of existing design methods. It is concluded that the ultimate bearing/ tearout resistances of austenitic and duplex connections are not simply proportionate to the ultimate strengths of the two materials. Given the same geometric design, the bearing resistance of a duplex connection is considerably higher than that of an austenitic connection, despite the similar ultimate strengths of the two materials. This difference in bearing performance is attributed to the different strain-hardening characteristics of austenitic and duplex materials, as well as the premature shear cracking in austenitic connections that leads to insufficiently developed strain-hardening. In comparison, the tearout resistances of austenitic and duplex connections with the same geometry are much closer, since the smaller end distance leads to more uniform deformations and more completely developed strain-hardening. Moreover, the combined bearing and tearout resistance of multi-bolt connections is found to be lower than the sum of the respective resistances of individual bolts. Finally, an updated design method is proposed that can accurately predict the bearing/tearout resistance of both austenitic and duplex stainless steel bolted connections. Proper partial factors are determined for the proposed method based on a reliability analysis.
引用
收藏
页数:21
相关论文
共 50 条
  • [21] Characteristics of Duplex Coating on Austenitic Stainless Steel
    Joska, Z.
    Kadlec, J.
    Hruby, V.
    Mrazkova, T.
    Manas, K.
    MATERIALS STRUCTURE & MICROMECHANICS OF FRACTURE, 2011, 465 : 255 - 258
  • [22] Ultimate strength of lean duplex stainless steel single-shear bolted connections with four bolts
    Kim, GeunYoung
    Kim, TaeSoo
    Hwang, BoKyung
    Kim, JunSu
    THIN-WALLED STRUCTURES, 2020, 155
  • [23] Testing and design of stainless steel staggered bolted connections
    dos Santos, Joao de J.
    Liang, Yating
    Zhao, Ou
    de Andrade, Sebastiao A. L.
    de Lima, Luciano R. O.
    Gardner, Leroy
    Vellasco, Pedro C. G. da S.
    ENGINEERING STRUCTURES, 2021, 231
  • [24] Bearing design of cold formed steel bolted connections
    Rogers, CA
    Hancock, GJ
    LIGHT-WEIGHT STEEL AND ALUMINIUM STRUCTURES, 1999, : 601 - 608
  • [25] Bearing behavior of bolted connections in high strength steel
    Wang, Yan-Bo
    Lyu, Yi-Fan
    Li, Guo-Qiang
    ADVANCES IN ENGINEERING MATERIALS, STRUCTURES AND SYSTEMS: INNOVATIONS, MECHANICS AND APPLICATIONS, 2019, : 1306 - 1311
  • [26] Experimental and numerical study on reduction coefficient of the shear capacity of austenitic long stainless-steel bolted connections
    Zhao, Jun
    Wang, Zhuang
    Peng, Yang
    Liu, Xuan
    Dong, Jun
    ENGINEERING STRUCTURES, 2022, 267
  • [27] Experimental and numerical study on reduction coefficient of the shear capacity of austenitic long stainless-steel bolted connections
    Zhao, Jun
    Wang, Zhuang
    Peng, Yang
    Liu, Xuan
    Dong, Jun
    Engineering Structures, 2022, 267
  • [28] Shear resistance of austenitic and duplex stainless steel bolts
    Stranghoener, Natalie
    Abraham, Christoph
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2021, 184
  • [29] Testing of Wire Arc Additively Manufactured Duplex Stainless Steel Double-Lap Shear Bolted Connections
    Zuo, Wenkang
    Chen, Man-Tai
    Zhao, Ou
    Gardner, Leroy
    JOURNAL OF STRUCTURAL ENGINEERING, 2025, 151 (02)
  • [30] Bearing factors of cold-formed stainless steel double shear bolted connections at elevated temperatures
    Cai, Yancheng
    Young, Ben
    THIN-WALLED STRUCTURES, 2016, 98 : 212 - 229