Optimizing Low-Dose [18F]FDG-PET/CT Scans: Ensuring Quality Amid Radiotracer Availability Challenges - Insights from a Peripheral Tertiary Care Center

被引:0
|
作者
Tayal, Sachin [1 ,2 ]
Jain, Yash [1 ,2 ]
Thakur, Sonali [1 ,2 ]
Shukla, Varun [1 ,2 ]
Venkatachalam, Manikandan Marappagounder [1 ,2 ]
Kumar, Ajay [1 ,2 ]
Sinha, Ritwik [1 ,2 ]
机构
[1] Homi Bhabha Canc Hosp, Dept Nucl Med & Mol Imaging, Varanasi, India
[2] Homi Bhabha Natl Inst HBNI, Mahamana Pandit Madan Mohan Malaviya Canc Ctr, Tata Mem Ctr, Varanasi, India
来源
INDIAN JOURNAL OF NUCLEAR MEDICINE | 2024年 / 39卷 / 04期
关键词
F-18-fluorodeoxyglucose; image and dose optimization; positron emission tomography-computed tomography; TIME-OF-FLIGHT; TF PET/CT SCANNER; PERFORMANCE EVALUATION; FDG PET/CT;
D O I
10.4103/ijnm.ijnm_90_24
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background:The introduction of positron emission tomography/computed tomography (PET/CT) has significantly advanced medical imaging. In oncology, 18F-fluorodeoxyglucose (18F-FDG) PET/CT is particularly crucial for staging, evaluating treatment response, monitoring follow-up, and planning radiotherapy. However, in resource limiting hospitals, the availability of fluorine-labeled 18F-FDG limits optimal scan acquisition. This study aims to determine the optimal dosage and acquisition time to maximize patient throughput during shortages. Aim and Objective:To optimize low-dose 18F-FDG scan protocols while maintaining high image quality despite radiotracer availability challenges. Materials and Methods:PET/CT scans were performed using GE's Discovery IQ 5-ring, 16-slice system within 40-60 minutes of intravenous 18F-FDG injection. The protocol was adjusted to a low-dose (0.05 mCi/kg of 18F-FDG), and the PET data acquisition time was increased to 3 min per bed position to ensure image quality. Results:Notable differences were observed in image quality scores based on varying acquisition times, with the extended acquisition time helping maintain diagnostic standards despite reduced tracer doses. Conclusion:The high sensitivity and long axial length of the PET/CT system (with five rings spanning 26 cm AFOV) can significantly alleviate the challenges faced by cyclotron-dependent centers. By leveraging the increased sensitivity, we successfully reduced the injected activity rather than the scan time to address the tracer shortage at our institute. This approach proved to be effective in maintaining image quality and patient care standards.
引用
收藏
页码:292 / 298
页数:7
相关论文
共 37 条
  • [21] Comparison of PET results acquired from low-dose 18F-FDG PET/CT and PET/MRI in patients with multiple myeloma: A feasibility study
    Sachpekidis, Christos
    Goldschmidt, Hartmut
    Hillengass, Jens
    Hose, Dirk
    Delorme, Stefan
    Schlemmer, Heinz-Peter
    Haberkorn, Uwe
    Dimitrakopoulou-Strauss, Antonia
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [22] Investigating Low-Dose Image Quality in Whole-Body Pediatric 18F-FDG Scans Using Time-of-Flight PET/MRI
    Schmall, Jeffrey P.
    Surti, Suleman
    Otero, Hansel J.
    Servaes, Sabah
    Karp, Joel S.
    States, Lisa J.
    JOURNAL OF NUCLEAR MEDICINE, 2021, 62 (01) : 123 - 130
  • [23] Utility of 18F-FDG PET/CT in Management of Pancreatic and Periampullary Masses-Prospective Study from a Tertiary Care Center
    Reddy, Chandra Teja S.
    Mohan, Krishna V. S.
    Jeepalem, Sai Moulika
    Manthri, Ranadheer
    Kalawat, Tekchand
    Reddy, Venkatarami V.
    Hulikal, Narendra
    Devi, Vijaya Lakshmi B.
    INDIAN JOURNAL OF SURGICAL ONCOLOGY, 2022, 13 (02) : 288 - 298
  • [24] Implication of small-voxel reconstruction under limited acquisition time in pediatric oncology using low-dose total-body [18F]- FDG-PET
    Li, Ying-He
    Zeng, Jiling
    Cao, Liu-Yi
    Zhao, Yumo
    Hu, Ying-Ying
    JOURNAL OF NUCLEAR MEDICINE, 2023, 64
  • [25] Effective Dose Estimation of Torso 18F FDG PET/CT Imaging from Real-World Data in a High-Volume Center
    Ryu, Jeongryul
    Oh, Jungsu
    Kim, Yong-il
    Han, Sangwon
    Kim, Jae Seung
    Ryu, Jin-Sook
    JOURNAL OF NUCLEAR MEDICINE, 2023, 64
  • [26] A Method to Improve the Semiquantification of 18F-FDG Uptake: Reliability of the Estimated Lean Body Mass Using the Conventional, Low-Dose CT from PET/CT
    Decazes, Pierre
    Metivier, Denis
    Rouquette, Alexandra
    Talbot, Jean-Noel
    Kerrou, Khaldoun
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57 (05) : 753 - 758
  • [27] Low dose optimization for total-body 2-[18F]FDG PET/CT imaging: a single-center study on feasibility based on body mass index stratification
    Gu, Taoying
    Liu, Siwei
    Hou, Xiaoguang
    Zhao, Liwei
    Ng, Yee Ling
    Wang, Jingyi
    Shi, Hongcheng
    EUROPEAN RADIOLOGY, 2025, 35 (04) : 1881 - 1893
  • [28] Potential application of 18F-FDG PET/CT scan in multisystem and single system Langerhans cell histiocytosis-a tertiary care center experience from 2011 to 2017
    Kumar, R.
    Mittal, B. R.
    Singh, H.
    Bhattacharya, A.
    Prakash, G.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S38 - S38
  • [29] EVALUATION OF 18F-FDG PET/CT IN EARLY DETECTION OF DISTANT METASTASES IN TRIPLE-NEGATIVE BREAST CANCER-A PROSPECTIVE STUDY FROM A TERTIARY CARE CENTER IN INDIA
    Yadav, Surekha
    INTERNAL MEDICINE JOURNAL, 2023, 53 : 24 - 25
  • [30] Clinical Value of a One-Stop-Shop Low-Dose Lung Screening Combined with 18F-FDG PET/CT for the Detection of Metastatic Lung Nodules from Colorectal Cancer
    Han Y.-H.
    Lim S.T.
    Jeong H.-J.
    Sohn M.-H.
    Nuclear Medicine and Molecular Imaging, 2016, 50 (2) : 144 - 149