Time-of-Flight Neutron Reflectometer for the DARIA Compact Neutron Source: Monte Carlo Simulation

被引:0
|
作者
Grigoryeva, N. A. [1 ]
Kovalenko, N. A. [2 ,3 ]
Grigoriev, S. V. [2 ,3 ]
机构
[1] Russian Acad Sci, Mikheev Inst Met Phys, Ural Branch, Ekaterinburg 620108, Russia
[2] St Petersburg State Univ, St Petersburg 199034, Russia
[3] Kurchatov Inst, Konstantinov Petersburg Nucl Phys Inst, Nucl Res Ctr, Gatchina 188300, Leningradskaya, Russia
来源
JOURNAL OF SURFACE INVESTIGATION | 2024年 / 18卷 / 06期
关键词
DARIA compact neutron source; reflectometer; modeling; transmitted-pulse resolution of a reflectometer; Monte Carlo method; FILM;
D O I
10.1134/S102745102470160X
中图分类号
O469 [凝聚态物理学];
学科分类号
070205 ;
摘要
Two types of polarized neutron reflectometers have been simulated for the compact neutron source DARIA (Dedicated for Academical Research and Industrial Application), depending on the type of target assembly with thermal or cryogenic moderators. Modeling and optimization of reflectometers were carried out using McStas software package by the Monte Carlo method with specified momentum transfer resolution Delta q/q <= 5% for reflection angles greater than the critical angle theta(cr) and a neutron beam horizontal divergence of Delta theta <= 0.1 degrees for theta < theta(cr) and Delta theta <= 0.033 degrees for theta > theta(cr). To reduce losses in neutrons, neutron guides with a supermirror coating have been proposed. A system of choppers makes it possible to create a neutron spectrum of the required width on a sample.
引用
收藏
页码:1602 / 1614
页数:13
相关论文
共 50 条
  • [21] The Proton Linac for Compact Neutron Source Daria
    Kropachev, G.
    Kulevoy, T.
    Sitnikov, A.
    JOURNAL OF SURFACE INVESTIGATION, 2019, 13 (06): : 1126 - 1131
  • [22] Simulation of the direct geometry spectrometer for neutron time of flight based on the Monte Carlo method to calculate the energy spectrum of the neutron source
    Hosseini, Seyed Abolfazl
    Mehrabi, Mohammad
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 949
  • [23] NEUTRON TIME-OF-FLIGHT SPECTROMETER WITH BETATRON SOURCE
    YEATER, ML
    GAERTTNER, ER
    BALDWIN, GC
    PHYSICAL REVIEW, 1953, 91 (02): : 451 - 451
  • [24] Resolution correction for time-of-flight neutron scattering experiments using the Monte Carlo method
    Ochanomizu Univ, Tokyo, Japan
    Jpn J Appl Phys Part 2 Letter, 11 A (L1474-L1477):
  • [25] Resolution correction for time-of-flight neutron scattering experiments using the Monte Carlo method
    Todate, Y
    Taniguchi, S
    Tajima, K
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS & EXPRESS LETTERS, 1997, 36 (11A): : L1474 - L1477
  • [26] MCGRtof:: Monte Carlo G(r) with resolution corrections for time-of-flight neutron diffractometers
    Tucker, MG
    Dove, MT
    Keen, DA
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2001, 34 : 780 - 782
  • [27] Diting: A polarized time-of-flight neutron reflectometer at CMRR reactor in China
    Li, Xinxi
    Huang, Chaoqiang
    Wang, Yan
    Chen, Bo
    Sun, Guang'ai
    Liu, Yaoguang
    Gong, Jian
    Kang, Wu
    Liu, Hangang
    EUROPEAN PHYSICAL JOURNAL PLUS, 2016, 131 (11):
  • [28] Diting: A polarized time-of-flight neutron reflectometer at CMRR reactor in China
    Xinxi Li
    Chaoqiang Huang
    Yan Wang
    Bo Chen
    Guang’ai Sun
    Yaoguang Liu
    Jian Gong
    Wu Kang
    Hangang Liu
    The European Physical Journal Plus, 131
  • [29] Design of the Proton Injector for Compact Neutron Source DARIA
    V. A. Skalyga
    I. V. Izotov
    S. S. Vybin
    T. V. Kulevoy
    G. N. Kropachev
    A. L. Sitnikov
    S. V. Grigoriev
    Journal of Surface Investigation: X-ray, Synchrotron and Neutron Techniques, 2022, 16 : 427 - 433
  • [30] Design of the proton injector for compact neutron source DARIA
    Skalyga, V. A.
    Izotov, I., V
    Vybin, S. S.
    Kulevoy, T., V
    Kropachev, G. N.
    Sitnikov, A. L.
    Grigoriev, S., V
    19TH INTERNATIONAL CONFERENCE ON ION SOURCES - ICIS2021, 2022, 2244