Generating Osmotic Power Using Waste Effluents for Pressure-Retarded Osmosis

被引:0
|
作者
AL-Musawi, Osamah A. H. [1 ]
Mohammad, Abdul Wahab [2 ]
Mahood, Hameed B. [3 ,4 ]
Ang, Wei Lun [1 ]
Mahmoudi, Ebrahim [1 ]
Kadhum, Abdul Amir H. [5 ]
机构
[1] Univ Kebangsaan Malaysia, Dept Chem & Proc Engn, Bangi, Malaysia
[2] Univ Sharjah, Coll Engn, Chem & Water Desalinat Engn Program, Sharjah, U Arab Emirates
[3] Univ Birmingham, Ctr Sustainable Cooling, Sch Chem Engn, Birmingham B15 2TT, England
[4] Univ Warith Al Anbiyaa, Coll Engn, Karbala 56001, Iraq
[5] Univ Al Ameed, Karbala, Iraq
关键词
Pressure-retarded osmosis; Renewable energy; Spiral-wound membrane; Wastewater; SPIRAL WOUND MODULE; MEMBRANE PROCESSES; SALINITY GRADIENT; REVERSE-OSMOSIS; FLUX BEHAVIOR; PERFORMANCE; ENERGY; DESALINATION; WATER; FO;
D O I
10.1007/s13369-024-09751-7
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Pressure-retarded osmosis (PRO) has a chemical potential to generate sustainable energy by utilising a semi-permeable membrane. RO-brine management with effluents being disposed of and energy usage are two issues that RO systems and deionised units face. The energy generation using the PRO techniques is proposed to address both of these issues practically. PRO can be used and integrated with the configuration of RO-brine as draw solution (DS) and effluent from demineralisation unit as feed solution (FS) that may generate the osmotic power density when it is applied. In this study, osmotic pressure for DS and FS was computed experimentally to predict W-p of the PRO, and the performance of the PRO process was evaluated using various scenarios, which included the spatial process parameters of applied pressure, concentrations and flow rates for DS and FS. In this approach, the effluent solutions could serve as an inflow source. Additionally, there is no need for pre-treatment of the DS and FS, as is required in the common PRO system. Experiments were conducted to estimate the transport properties of commercial SW-membranes. Based on these experimental scenarios, trials were conducted using three DS of NaCl concentrations of similar to 51.8, 44.1, and 36.2 g/L to investigate the viability of the PRO, where the largest W-p reached 2.83, 2.32, and 1.94 W/m(2), while the smallest W-p was 1.5,1.18, and 1.0 W/m(2), and the flux reversal point of the Delta(pPRO) was similar to 10.8 bar and 9.4 bar, corresponding to the different flow rates. Additionally, the effects of dilution on the system were also observed.
引用
收藏
页码:4295 / 4311
页数:17
相关论文
共 50 条
  • [31] Pressure-retarded osmotic power system model considering non-ideal effects
    Maisonneuve, Jonathan
    Pillay, Pragasen
    Laflamme, Claude B.
    RENEWABLE ENERGY, 2015, 75 : 416 - 424
  • [32] Raising the Bar: Increased Hydraulic Pressure Allows Unprecedented High Power Densities in Pressure-Retarded Osmosis
    Straub, Anthony P.
    Yip, Ngai Yin
    Elimelech, Menachem
    ENVIRONMENTAL SCIENCE & TECHNOLOGY LETTERS, 2014, 1 (01): : 55 - 59
  • [33] A tool for assessing the scalability of pressure-retarded osmosis (PRO) membranes
    Manzoor, Husnain
    Selam, Muaz A.
    Rahman, Fahim Bin Abdur
    Adham, Samer
    Castier, Marcelo
    Abdel-Wahab, Ahmed
    RENEWABLE ENERGY, 2020, 149 : 987 - 999
  • [34] THE USE OF PRESSURE-RETARDED OSMOSIS FOR INCREASING THE SOLAR POND EFFICIENCY
    BEMPORAD, GA
    SOLAR ENERGY, 1992, 48 (06) : 375 - 379
  • [35] Semipermeable Membrane Mass Transfer in Pressure-Retarded Osmosis Process
    You, Yonghua
    Huang, Suyi
    Yang, Yi
    Liu, Chao
    Wu, Zhilin
    Yu, Xiangfei
    ADVANCES IN COMPUTER SCIENCE AND ENGINEERING, 2012, 141 : 307 - 315
  • [36] Concentration and Temperature Effects on Water and Salt Permeabilities in Osmosis and Implications in Pressure-Retarded Osmosis
    Sivertsen, Edvard
    Holt, Torleif
    Thelin, Willy R.
    MEMBRANES, 2018, 8 (03)
  • [37] Numerical studies on the pressure-retarded osmosis (PRO) system with the spiral wound module for power generation
    Hong, Sung-Soo
    Ryoo, Won
    Chun, Myung-Suk
    Lee, Seung Oh
    Chung, Gui-Yung
    DESALINATION AND WATER TREATMENT, 2014, 52 (34-36) : 6333 - 6341
  • [38] Energy comparison and cost estimation of pressure-retarded osmosis using spiral wound membrane
    AL-Musawi, Osamah A. H.
    Mohammad, Abdul Wahab
    Mahood, Hameed B.
    Mahmoudi, Ebrahim
    Ang, Wei Lun
    Kadhum, Abdul Amir H.
    DESALINATION AND WATER TREATMENT, 2024, 320
  • [39] Numerical Studies on the Effects of the Channel-Inlet-Pressure Difference in the Pressure-Retarded Osmosis (PRO) Power System
    Hong, Sung Soo
    Ryoo, Won
    Chun, Myung-Suk
    Chung, Gui Yung
    KOREAN CHEMICAL ENGINEERING RESEARCH, 2014, 52 (01): : 68 - 74
  • [40] Outer-Selective Pressure-Retarded Osmosis Hollow Fiber Membranes from Vacuum-Assisted Interfacial Polymerization for Osmotic Power Generation
    Sun, Shi-Peng
    Chung, Tai-Shung
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2013, 47 (22) : 13167 - 13174