Time-dependent simulation of blood flow through an abdominal aorta with iliac arteries

被引:0
|
作者
Gorski, Grzegorz [1 ]
Kucab, Krzysztof [1 ]
机构
[1] Univ Rzeszow, Inst Phys, Coll Nat Sci, ul Pigon 1, PL-35310 Rzeszow, Poland
来源
关键词
Blood flow; Aortic stenosis; Turbulence models; WALL SHEAR-STRESS; NUMERICAL-SIMULATION; PULSATILE FLOW; CAROTID BIFURCATION; COMPUTED-TOMOGRAPHY; TURBULENT-FLOW; IN-VIVO; ATHEROSCLEROSIS; FLUID; VALIDATION;
D O I
10.1007/s00249-024-01724-w
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Atherosclerosis is one of the important diseases of the circulatory system because atherosclerotic plaques cause significant disruption of blood flow. Therefore, it is very important to properly understand these processes and skillfully simulate blood flow. In our work, we consider blood flow through an abdominal aorta with iliac arteries, assuming that the right iliac artery is narrowed by an atherosclerotic lesion. Blood flow is simulated using the laminar, standard k-omega\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$k-\omega$$\end{document} and standard k-& varepsilon;\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$k-\epsilon$$\end{document} models. The obtained results show that despite the use of identical initial conditions, the distribution of velocity flow and wall shear stress depends on the choice of flow simulation model. For the k-& varepsilon;\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$k-\epsilon$$\end{document} model, we obtain higher values of speed and wall shear stress on atherosclerotic plaque than in the other two models. The laminar and k-omega\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$k-\omega$$\end{document} models predict larger areas where reverse blood flow occurs in the area behind the atherosclerotic lesion. This effect is associated with negative wall shear stress. These two models give very similar results. The results obtained by us, and those reported in the literature, indicate that k-omega\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$k-\omega$$\end{document} model is the most suitable for blood flow analysis.
引用
收藏
页码:429 / 445
页数:17
相关论文
共 50 条
  • [31] Numerical simulation of time-dependent methane flow
    Ediz, I.G.
    Edwards, J.S.
    Mining science & technology, 1991, 12 (01): : 1 - 15
  • [32] Time-dependent simulation of conduction through a molecule
    Tomfohr, JK
    Sankey, OF
    PHYSICA STATUS SOLIDI B-BASIC RESEARCH, 2001, 226 (01): : 115 - 123
  • [33] Surgical treatment for primary infected aneurysm of the descending thoracic aorta, abdominal aorta, and iliac arteries
    Hsu, RB
    Tsay, YG
    Wang, SS
    Chu, SH
    JOURNAL OF VASCULAR SURGERY, 2002, 36 (04) : 746 - 750
  • [34] MATHEMATICAL ANALYSIS OF BLOOD FLOW THROUGH AN ARTERIAL SEGMENT WITH TIME-DEPENDENT STENOSIS
    Misra, J. C.
    Adhikary, S. D.
    Shit, G. C.
    MATHEMATICAL MODELLING AND ANALYSIS, 2008, 13 (03) : 401 - 412
  • [35] Simulation of blood flow in the human abdominal aorta using the LBGK method
    Leitner, Daniel
    Wassertheurer, Siegfried
    Emrich, Stefan
    Breitenecker, Felix
    PROCEEDINGS OF THE ITI 2008 30TH INTERNATIONAL CONFERENCE ON INFORMATION TECHNOLOGY INTERFACES, 2008, : 439 - +
  • [36] Numerical simulation of blood flow in a flexible stenosed abdominal real aorta
    Alishahi, M.
    Alishahi, M. M.
    Emdad, H.
    SCIENTIA IRANICA, 2011, 18 (06) : 1297 - 1305
  • [37] 3D SIMULATION OF BLOOD FLOW THROUGH NEW DESIGNED STENT GRAFT IN ABDOMINAL AORTA
    Begic, N.
    Karahusic, A. Botonjic
    Kostic, T.
    ATHEROSCLEROSIS, 2019, 287 : E160 - E160
  • [38] Hydatid cyst of the abdominal aorta and bilateral common iliac arteries -: A case report
    Karapinar, K
    Ergül, Z
    Keskin, A
    Bugra, O
    Düzgün, C
    Zengin, M
    JOURNAL OF CARDIOVASCULAR SURGERY, 1999, 40 (04): : 583 - 585
  • [39] AORTO-INTESTINAL FISTULAS FOLLOWING OPERATIONS ON ABDOMINAL AORTA AND ILIAC ARTERIES
    SHEIL, AGR
    REEVE, TS
    LITTLE, JM
    COUPLAND, GA
    LOEWENTHAL, J
    BRITISH JOURNAL OF SURGERY, 1969, 56 (11) : 840 - +
  • [40] ANEURYSMS OF SUBRENAL ABDOMINAL AORTA AND ILIAC ARTERIES - PROPOS OF AN EXPERIENCE IN 64 CASES
    LEBAS, P
    LANFRANCHI, JP
    ROUVILLE, GB
    DUPLAY, H
    BOYER, R
    BISQUERRA, E
    MATTEI, M
    ANNALES DE CHIRURGIE, 1972, 26 (9-10): : 555 - +