Electrochemical determination of uric acid in the presence of dopamine and riboflavin using a poly(resorcinol)-modified carbon nanotube sensor

被引:0
|
作者
Kanthappa, B. [1 ]
Manjunatha, J. G. [1 ]
Aldossari, Samar A. [2 ]
Raril, C. [3 ]
机构
[1] Mangalore Univ, FMKMC Coll, Constituent Coll, Dept Chem, Madikeri 571201, Karnataka, India
[2] King Saud Univ, Coll Sci, Dept Chem, POB 2455, Riyadh 11451, Saudi Arabia
[3] Nanjing Univ, Sch Chem & Chem Engn, State Key Lab Analyt Chem Life Sci, Nanjing 210023, Peoples R China
来源
SCIENTIFIC REPORTS | 2025年 / 15卷 / 01期
关键词
Carbon Nanotube electrode; Resorcinol; Uric acid; Riboflavin; Dopamine; Electrochemical Analyser; SIMULTANEOUS VOLTAMMETRIC DETECTION; ASCORBIC-ACID; PASTE ELECTRODE; CHEMILUMINESCENCE; COMPOSITE;
D O I
10.1038/s41598-025-90235-5
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
In this study, an electrochemical sensor based on a poly(resorcinol) modified carbon nanotube paste electrode (P(RS)/MCNTPE) was successfully developed for the sensitive and selective detection of uric acid (UA) in the presence of dopamine (DA) and riboflavin (RFN). The sensor shows excellent performance in a 0.2 M phosphate buffer solution (PBS) at pH 7.0 with a scan rate 0.1 V/s. Various electrochemical methods were studied including cyclic voltammetry (CV), differential pulse voltammetry (DPV), and electrochemical impedance spectroscopy (EIS). Morphological analysis using scanning electron microscopy (SEM) conformed the enhanced surface properties of the bare carbon nanotubes paste electrode (BCNTPE) and the P(RS)/MCNTPE. The effect of pH, scan rate changes 0.025 to 0.25 V/s, revealed that the oxidation of UA follows an adsorption-controlled process. For UA concentration changes from 20 mu M and 380 mu M, sensor exhibited a limit of detection (LOD) of 0.18 mu M and a limit of quantification (LOQ) of 0.61 mu M. Optimal UA response was observed at pH 7.0. The sensor shows good stability, repeatability, and reproducibility. Its analytical applicability was successfully validated in real sample analysis.
引用
收藏
页数:17
相关论文
共 50 条
  • [21] Electrochemical sensor using cobalt oxide-modified porous carbon for uric acid determination
    Changyun Quan
    Wenxuan Chen
    Minghui Yang
    Yi Hou
    Microchimica Acta, 2023, 190
  • [22] PhosphoMolybdic Acid and Poly(Paraphenylenediamine) Modified Carbon Paste Electrode using Voltammetric Determination of Dopamine and Uric Acid
    Lakshmi, Gundluru Bhagya
    Reddy, Yellala V. Rami
    Ravi, Raminani
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2021, 13 (02): : 176 - 189
  • [23] Selective Voltammetric Determination of Carbidopa in the Presence of Uric Acid Using a Modified Carbon Nanotube Paste Electrode
    Beitollahi, Hadi
    Raoof, Jahan-Bakhsh
    Karimi-Maleh, Hassan
    Hosseinzadeh, Rahman
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2012, 4 (01): : 32 - 44
  • [24] Electrochemical polymerized DL-phenylalanine modified carbon nanotube sensor for the selective and sensitive determination of caffeic acid with riboflavin
    Kanthappa, B.
    Manjunatha, J. G.
    Osman, Sameh Mohamed
    Ataollahi, Narges
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [25] DISPOSABLE MULTIWALLED CARBON NANOTUBE PRINTED FILM ELECTROCHEMICAL DETERMINATION OF ACETAMINOPHEN, DOPAMINE, AND URIC ACID
    Tsierkezos, Nikos G.
    Ritter, Uwe
    Wetzold, Nora
    Huebler, Arved Carl
    ANALYTICAL LETTERS, 2014, 47 (17) : 2829 - 2843
  • [26] Electrochemical sensor for detection of uric acid in the presence of ascorbic acid and dopamine using the poly(DPA)/SiO2@Fe3O4 modified carbon paste electrode
    Reddy, Y. Veera Manohara
    Sravani, Bathinapatla
    Agarwal, Shilpi
    Gupta, Vinod Kumar
    Madhavi, G.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2018, 820 : 168 - 175
  • [27] Determination of Dopamine in the Presence of Ascorbic Acid Using a Poly(Amidosulfonic Acid) Modified Glassy Carbon Electrode
    Yuzhong Zhang
    Guiying Jin
    Zhousheng Yang
    Hong Zhao
    Microchimica Acta, 2004, 147 : 225 - 230
  • [28] Determination of dopamine in the presence of ascorbic acid using a poly(amidosulfonic acid) modified glassy carbon electrode
    Zhang, YZ
    Jin, GY
    Yang, ZS
    Zhao, H
    MICROCHIMICA ACTA, 2004, 147 (04) : 225 - 230
  • [29] Determination of dopamine in the presence of ascorbic acid using poly(hippuric acid) modified glassy carbon electrode
    Zhao, H
    Zhang, YH
    Yuan, ZB
    ELECTROANALYSIS, 2002, 14 (14) : 1031 - 1034
  • [30] Selective electrochemical determination of uric acid in the presence of ascorbic acid using a carbon paste electrode modified with β-cyclodextrin
    Ramirez-Berriozabal, Minerva
    Galicia, Laura
    Gutierrez-Granados, Silvia
    Cortes, Jose Sandoval
    Herrasti, Pilar
    ELECTROANALYSIS, 2008, 20 (15) : 1678 - 1683