Does minimally invasive external fixation of proximal humerus fractures provide adequate stability? A biomechanical in vitro study

被引:0
|
作者
Greinwald, Markus [1 ]
Matschl, Franz [1 ]
Regenbogen, Stephan [2 ,3 ]
Paetzold, Robert [2 ]
Blonna, Davide [4 ]
Augat, Peter [1 ,5 ]
机构
[1] BG Unfallklin Murnau, Inst Biomech, Prof Kuntscher Str 8, D-82418 Murnau, Germany
[2] BG Unfallklin Murnau, Dept Trauma & Orthopaed Surg, Murnau, Germany
[3] Heidelberg Univ, BG Klin Ludwigshafen, Dept Traumatol, Ludwigshafen, Germany
[4] Univ Torino, AO Ordine Mauriziano Hosp, Dept Orthopaed & Traumatol, Turin, Italy
[5] Paracelsus Med Univ, Inst Biomech, Salzburg, Austria
关键词
Proximal humeral fracture; External fixator; Internal fixator; Biomechanics; Shoulder fractures; In vitro; Semi-rigid; Galaxy fixator; Philos plate; PERCUTANEOUS FIXATION; WIRE MIGRATION; REDUCTION;
D O I
10.1186/s12891-024-07977-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction Proximal humerus fractures are usually treated with rigid angle-stable plates or nails. As an alternative, semi-rigid, minimally invasive systems have been developed for supportive fixation. A new system uses this principle with 2.5 mm partially threaded pins and external fixation. Aim This study aimed to compare the fracture stability of the fixator with an angular stable plate about whether the mechanical stability is sufficient for early postoperative mobilisation. Materials and methods Human proximal humeri (paired, female, age >= 60, n = 8) were cut to a 3-part fracture and treated with an external fixator (Galaxy Shoulder, Orthofix) or an angular stable plate (Philos, DePuy Synthes). A physiological load was simulated in vitro based on a 45 degrees abduction motion. The load level was continuously increased from 10 to 320 N within 10,000 cycles simulating the loads during rehabilitation. This was followed by another 10,000 cycles at 320 N for fatigue testing. Fracture motion was recorded with a 3D camera. Fracture stability was evaluated at a partial load of 160 N and 240 N (simulating loads during early mobilisation). Results The fracture motion at the lateral aspect was significantly (p < 0.034) larger for the fixator compared to the plate both for axial and for shear movements, while at the medial aspects fracture motions were similar. Both fixation systems adequately stabilized the lateral tubercle fragment with no significant differences between fixation techniques. The migration of the fixator pins (1.1 +/- 1.0 mm) and valgus rotation of the head fragment were minimal (3.1 +/- 2.0 degrees). The maximum load level of 320 N was reached by all plate constructs and 3 fixator constructs. Conclusion Our results suggest that the external fixator system allows early but gentle postoperative mobilisation. More aggressive rehabilitation measures should be postponed after the healing of the fracture.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Minimally Invasive Polyaxial Locking Plate Fixation of Proximal Humeral Fractures: A Prospective Study
    Ruchholtz, Steffen
    Hauk, Carsten
    Lewan, Ulrike
    Franz, Daniel
    Kuehne, Christian
    Zettl, Ralph
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2011, 71 (06): : 1737 - 1744
  • [32] Minimally Invasive Surgery by Angular Stability Systems in Proximal Tibia Fractures - Biomechanical Characteristics and Preliminary Results
    Sirbu, P. D.
    Carata, E.
    Petreus, T.
    Munteanu, F.
    Popescu, C.
    Asaftei, R.
    Botez, P.
    INTERNATIONAL CONFERENCE ON ADVANCEMENTS OF MEDICINE AND HEALTH CARE THROUGH TECHNOLOGY, 2009, 26 : 413 - +
  • [33] Digital analysis of external fixation area of proximal humerus fractures in elderly patients
    Baorui Xing
    Yadi Zhang
    Xiuxiu Hou
    Yunmei Li
    Guoliang Li
    Guangpu Han
    BMC Musculoskeletal Disorders, 22
  • [34] Hybrid blade and locking plate fixation for proximal humerus fractures: a comparative biomechanical analysis
    Jabran, Ali
    Peach, Chris
    Zou, Zhenmin
    Ren, Lei
    BIOMEDICAL ENGINEERING ONLINE, 2018, 17
  • [35] EXTERNAL FIXATION OF DISPLACED FRACTURES OF THE PROXIMAL HUMERUS - TECHNIQUE AND PRELIMINARY-RESULTS
    KRISTIANSEN, B
    KOFOED, H
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1987, 69 (04): : 643 - 646
  • [36] Hybrid blade and locking plate fixation for proximal humerus fractures: a comparative biomechanical analysis
    Ali Jabran
    Chris Peach
    Zhenmin Zou
    Lei Ren
    BioMedical Engineering OnLine, 17
  • [37] Internal fixation of proximal humerus fractures. Influence of implant design on biomechanical properties
    Hessmann, MH
    Sternstein, W
    Krummenauer, F
    Hofmann, A
    Rommens, PM
    CHIRURG, 2005, 76 (02): : 167 - 174
  • [38] Digital analysis of external fixation area of proximal humerus fractures in elderly patients
    Xing, Baorui
    Zhang, Yadi
    Hou, Xiuxiu
    Li, Yunmei
    Li, Guoliang
    Han, Guangpu
    BMC MUSCULOSKELETAL DISORDERS, 2021, 22 (01)
  • [39] Does Proximal Humerus Inter Locking System (PHILOS) Plating Provide a Good Functional Outcome in Proximal Humerus Fractures?
    Ethiraj, Prabhu
    Venkataraman, Sagar
    Karthik, S. J.
    Shanthappa, Arun H.
    Agarawal, Sandesh
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (06)
  • [40] Biomechanical in vitro assessment of screw augmentation in locked plating of proximal humerus fractures
    Roederer, Goetz
    Scola, Alexander
    Schmoelz, Werner
    Gebhard, Florian
    Windolf, Markus
    Hofmann-Fliri, Ladina
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2013, 44 (10): : 1327 - 1332