Effect of CAD-CAM block thickness and translucency on the polymerization of luting materials

被引:2
|
作者
Kaya, Bengu Dogu [1 ]
Ozturk, Selinsu [2 ]
Senol, Ayse Asli [1 ]
Kahramanoglu, Erkut [3 ]
Atali, Pinar Yilmaz [1 ]
Tarcin, Bilge [1 ]
机构
[1] Marmara Univ, Fac Dent, Dept Restorat Dent, Istanbul, Turkiye
[2] Marmara Univ, Inst Hlth Sci, Dept Restorat Dent, Istanbul, Turkiye
[3] Marmara Univ, Fac Dent, Dept Prosthodont, Istanbul, Turkiye
来源
BMC ORAL HEALTH | 2024年 / 24卷 / 01期
关键词
CAD-CAM block; Degree of conversion; Flowable resin composite; Luting material; Translucency; MECHANICAL-PROPERTIES; RESIN CEMENTS; CURING UNITS; CONVERSION; COMPOSITE; COLOR; OPALESCENCE; EFFICIENCY; OPACITY; ABILITY;
D O I
10.1186/s12903-024-05171-z
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim This in-vitro study aimed to evaluate the degree of conversion (DC) of dual-cured luting cement (Bifix QM, VOCO) and flowable composite (Grandio Flow, VOCO) under lithium disilicate glass-ceramic (IPS e.max CAD, Ivoclar Vivadent) and hybrid ceramic (Grandio Blocs, VOCO; Cerasmart, GC) CAD-CAM blocks with different thicknesses. Materials and methods Contrast ratio (CR), translucency (TPab, TP00), and opalescence (OP) parameters of 30 disc-shaped CAD-CAM blocks (n = 5) prepared with two different thicknesses (1.5 and 2 mm) and 8 mm diameters were calculated using a spectrophotometer (VITA Easyshade V, Zahnfabrik). A total of 36 Bifix QM and Grandio Flow samples were prepared at 100 mu m thickness using a specific setup by polymerizing from the top of the blocks. Following immersion in distilled water at 37 degrees C for 24 h, luting materials were examined by Fourier Transform Infrared Spectroscopy for DC calculation. Data were analyzed using One-way ANOVA, Kruskal Wallis, Mann Whitney U, and Independent Samples t-tests (p < 0.05). Results It was observed that, as the block thickness increased TPab, TP00, and OP decreased, while CR increased. There was no significant difference between the DC of Bifix QM and Grandio Flow when 1.5 mm blocks were used in all groups (p > 0.05). DC of Grandio Flow was significantly higher than Bifix QM under 2 mm-IPS e.max CAD (p = 0.011). Conclusion The translucency of the CAD-CAM blocks varies depending on their thickness. However, there was no significant difference in the DC of the luting materials depending on the block thickness. Further studies are needed on the use of flowable resin composites as luting material.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Impact of CAD/CAM Material Thickness and Translucency on the Polymerization of Dual-Cure Resin Cement in Endocrowns
    Ikemoto, Soshi
    Komagata, Yuya
    Yoshii, Shinji
    Masaki, Chihiro
    Hosokawa, Ryuji
    Ikeda, Hiroshi
    POLYMERS, 2024, 16 (05)
  • [32] Effect of polishing and bleaching on color, whiteness, and translucency of CAD/CAM monolithic materials
    Pena, Ranulfo Castillo
    Ramos, Alejandro Cardenas
    Reis, Jose Mauricio dos Santos Nunes
    Dovigo, Livia Nordi
    Salomon, Jean-Pierre Guy Olivier
    Perez, Maria del Mar
    Fonseca, Renata Garcia
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2024,
  • [33] Effect of Translucency and Curing Mode of Four CAD/CAM Materials on Polymerization Efficiency of Light and Dual Cure Resin Cements
    Shono, Nourah N.
    Elhejazi, Ahmed
    Maawadh, Ahmed
    Al Nahedh, Hend
    EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2022, : 230 - 238
  • [34] Effect of erosive media on microhardness and fracture toughness of CAD-CAM dental materials
    Alaaeldin Elraggal
    Rania Afifi
    Islam Abdelraheem
    BMC Oral Health, 22
  • [35] Grinding damage assessment for CAD-CAM restorative materials
    Curran, Philippe
    Cattani-Lorente, Maria
    Wiskott, H. W. Anselm
    Durual, Stephane
    Scherrer, Susanne S.
    DENTAL MATERIALS, 2017, 33 (03) : 294 - 308
  • [36] Impact of the Luting Technique on the Positioning of CAD-CAM Porcelain Laminate Veneers: An In Vitro Study
    D'Addazio, Gianmaria
    Amoroso, Federico
    Tafuri, Giuseppe
    Baima, Giacomo
    Santilli, Manlio
    Mussano, Federico
    Sinjari, Bruna
    PROSTHESIS, 2024, 6 (05): : 1095 - 1105
  • [37] Wear resistance and abrasiveness of CAD-CAM monolithic materials
    Ludovichetti, Francesco Saverio
    Trindade, Flavia Zardo
    Werner, Arie
    Kleverlaan, Cornelis Johannes
    Fonseca, Renata Garcia
    JOURNAL OF PROSTHETIC DENTISTRY, 2018, 120 (02):
  • [38] Effect of machining damage on the surface roughness and flexural strength of CAD-CAM materials
    Redwan, Hetaf
    Fan, Yuwei
    Giordano II, Russell
    JOURNAL OF PROSTHETIC DENTISTRY, 2025, 133 (03): : 872 - 880
  • [39] Effect of erosive media on microhardness and fracture toughness of CAD-CAM dental materials
    Elraggal, Alaaeldin
    Afifi, Rania
    Abdelraheem, Islam
    BMC ORAL HEALTH, 2022, 22 (01)
  • [40] Effect of virtual cement space and restorative materials on the adaptation of CAD-CAM endocrowns
    Zheng, Ziting
    Wang, Hebi
    Mo, Jiayao
    Ling, Zhiting
    Zeng, Yuting
    Zhang, Yuxin
    Wang, Jilei
    Yan, Wenjuan
    BMC ORAL HEALTH, 2022, 22 (01)