NebulaPlate: a droplet microfluidic platform to analyze platelet aggregation

被引:0
|
作者
Jiang, Zheyi [1 ]
Wei, Meng [1 ]
Zhu, Jiawei [2 ]
Wang, Chenguang [3 ]
Zhang, Tiantian [1 ]
Zhu, Wenjie [2 ]
Zhang, Rong [2 ]
Zhang, Kandi [1 ]
Zhang, Peng [1 ]
Lu, Yihua [1 ]
Chang, Alex Chia Yu [1 ,3 ]
Liu, Yifan [2 ,4 ,5 ]
Zhang, Junfeng [1 ]
机构
[1] Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 9, Sch Med, Dept Cardiol, Shanghai 200011, Peoples R China
[2] ShanghaiTech Univ, Sch Phys Sci & Technol, Shanghai 201210, Peoples R China
[3] Shanghai Jiao Tong Univ, Peoples Hosp 9, Shanghai Inst Precis Med, Sch Med, Shanghai 200125, Peoples R China
[4] Shanghai Clin Res & Trial Ctr, Shanghai 201210, Peoples R China
[5] ShanghaiTech Univ, State Key Lab Adv Med Mat & Devices, Shanghai 201210, Peoples R China
关键词
Platelet function; Platelet aggregation; Microdroplet; P-selectin; Microfluidic chip; PERCUTANEOUS CORONARY INTERVENTION; P-SELECTIN; MECHANISMS; REACTIVITY; THROMBOSIS; ASSAY; RESPONSES; OUTCOMES; THERAPY; POINT;
D O I
10.1186/s12951-025-03212-5
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
The accurate assessment of platelet activity is crucial in clinical practice and scientific research owing to the pivotal role of platelets in the progression of cardiovascular conditions, such as arterial thrombotic diseases. However, conventional platelet activity assessment methods are currently limited by their requirement of substantial blood samples and inadequate high-throughput capabilities, and therapeutic resistance induced by antiplatelet agents impedes treatment efficacy. In this study, we developed a microdroplet-based platelet function detection method, referred to as NebulaPlate, to achieve miniaturized and robust platelet activity assessment, thereby overcoming current challenges. NebulaPlate supports the merging of platelet samples with drugs confined in picoliter microdroplets and leverages an imaging-based analysis to automatically identify platelets, evaluate their aggregation, and determine P-selectin expression within the anchored microdroplets. We experimentally confirmed the feasibility of aggregation assays on NebulaPlate using various representative antiplatelet drugs. Requiring only 0.3 mL whole blood/chip, which corresponds to approximately 100 platelets/reaction, NebulaPlate reduced the consumption of platelet samples in a single assay. This represents a reduction of 10 times compared to that of conventional techniques. Moreover, our experimental results confirmed the validity and reproducibility of platelet function assays performed using NebulaPlate. Our research highlights important developments in the field of platelet activity assessment and provides fresh prospects for future antiplatelet therapies and personalized medicine. Moreover, it introduces new possibilities for research and clinical practice related to arterial thrombotic diseases.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] The effect of microfluidic chip geometry on droplet clustering in a high throughput droplet incubation platform for single-cell analysis
    Mirkale, K.
    Chatterjee, Dhiman
    PHYSICS OF FLUIDS, 2024, 36 (01)
  • [42] Droplet microfluidic SANS
    Adamo, Marco
    Poulos, Andreas S.
    Lopez, Carlos G.
    Martel, Anne
    Porcar, Lionel
    Cabral, Joa O. T.
    SOFT MATTER, 2018, 14 (10) : 1759 - 1770
  • [43] Evolution in Microfluidic Droplet
    Levin, Itay
    Aharoni, Amir
    CHEMISTRY & BIOLOGY, 2012, 19 (08): : 929 - 931
  • [44] Droplet-based microfluidic platform for viscosity measurement over extended concentration range
    Cochard-Marchewka, Paul
    Bremond, Nicolas
    Baudry, Jean
    LAB ON A CHIP, 2023, 23 (09) : 2276 - 2285
  • [45] Open-Channel Droplet Microfluidic Platform for Passive Generation of Human Sperm Microdroplets
    Nicholson, Tristan M.
    Tokihiro, Jodie C.
    Tu, Wan-chen
    Khor, Jian Wei
    Lee, Ulri N.
    Berthier, Erwin
    Amory, John K.
    Walsh, Thomas J.
    Muller, Charles H.
    Theberge, Ashleigh B.
    ACS BIOMATERIALS SCIENCE & ENGINEERING, 2025, 11 (03): : 1373 - 1378
  • [46] Sample-to-answer centrifugal microfluidic droplet PCR platform for quantitation of viral load
    Malic, Lidija
    Clime, Liviu
    Moon, Byeong-Ui
    Nassif, Christina
    Da Fonte, Dillon
    Brassard, Daniel
    Lukic, Ljuboje
    Geissler, Matthias
    Morton, Keith
    Charlebois, Denis
    Veres, Teodor
    LAB ON A CHIP, 2024, 24 (20) : 4755 - 4765
  • [47] Passive Droplet Microfluidic Platform for High-Throughput Screening of Microbial Proteolytic Activity
    Potenza, Luca
    Kozon, Lukasz
    Drewniak, Lukasz
    Kaminski, Tomasz S.
    ANALYTICAL CHEMISTRY, 2024, 96 (40) : 15931 - 15940
  • [48] XPORT ENTRAP: A droplet microfluidic platform for enhanced DNA transfer between microbial species
    Wippold, Jose A.
    Chu, Monica
    Renberg, Rebecca
    Li, Yuwen
    Adams, Bryn
    Han, Arum
    NEW BIOTECHNOLOGY, 2024, 81 : 10 - 19
  • [49] Droplet-assisted electrospray phase separation using an integrated silicon microfluidic platform
    Zhang, Yan
    Kim, Sungho
    Shi, Weihua
    Zhao, Yaoyao
    Park, Insu
    Brenden, Christopher
    Iyer, Hrishikesh
    Jha, Prasoon
    Bashir, Rashid
    Sweedler, Jonathan V.
    Vlasov, Yurii
    LAB ON A CHIP, 2021, 22 (01) : 40 - 46
  • [50] spinDrop: a droplet microfluidic platform to maximise single-cell sequencing information content
    De Jonghe, Joachim
    Kaminski, Tomasz S.
    Morse, David B.
    Tabaka, Marcin
    Ellermann, Anna L.
    Kohler, Timo N.
    Amadei, Gianluca
    Handford, Charlotte E.
    Findlay, Gregory M.
    Zernicka-Goetz, Magdalena
    Teichmann, Sarah A.
    Hollfelder, Florian
    NATURE COMMUNICATIONS, 2023, 14 (01)