The effect of various denture cleansers on the physical and mechanical properties of CAD/CAM and heat-polymerized denture base materials: an in vitro study

被引:0
|
作者
Selin, Ozyurt Tekin [1 ]
Ipek, Caglar [1 ]
机构
[1] Recep Tayyip Erdogan Univ, Fac Dent, Dept Prosthodont, Menderes Blvd 612 Rize, TR-53020 Rize, Turkiye
关键词
Acrylic resin; CAD/CAM; Denture bases; Denture cleansers; Flexural strength; FABRICATING COMPLETE DENTURES; SURFACE-ROUGHNESS; CHEMICAL DISINFECTION; ACRYLIC RESINS; MICROWAVE; IMMERSION; HARDNESS; COLOR;
D O I
10.1007/s00784-024-06016-3
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
ObjectivesTo investigate the effects of denture cleansers on the various properties of CAD/CAM and heat-polymerized polymethyl methacrylate (PMMA). Materials and methodsTwo different brands of heat-polymerized and two of milled PMMA were fabricated (n = 50), in total 200. Each group was randomly divided into five subgroups (n = 10): control groups (D1) kept in distilled water, cleaning tablets (D2, D3), neutral (D4) and acidic electrolyzed acid water (EAW) (D5). Surface roughness, hardness and flexural strength values were evaluated. Data were statistically analyzed with two-way ANOVA and Tukey post hoc test for comparison (p<0.05). ResultsThe milled group showed significantly lower surface roughness, greater surface hardness, and higher flexural strength values than heat polymerized denture bases (p<0.05). The denture cleansers had no significant effect on the surface roughness values of the milled specimens (p>0.05), whereas the specimens in the heat-polymerized groups and treated with D5 showed greater surface roughness values compared with the other cleaning agents (p > 0.05). The denture cleansers had no significant effect on surface hardness and flexural strength of heat polymerize groups (p > 0.05). However, D2, D3 and D5 cleaning agent decreased the hardness values of the milled group (p<0.05) and D5 cleaning agent decreased the flexural strength of the milled group (p<0.05). ConclusionsIt was observed that the applied denture cleansers affected the surface roughness, surface hardness, and flexural strength values of both denture bases but within a clinically acceptable value. Clinical RelevanceCAD/CAM denture bases showed significantly higher physical and mechanical properties than to heat-polymerized base materials. Although the applied neutral EAW cleaners give desired results for denture bases, clinical studies are needed for biological compatibility.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] A comparative evaluation of physical properties of CAD/CAM complete denture resins- an in vitro study
    Arora, Ojasvini
    Ahmed, Nabeel
    Siurkel, Yuliia
    Ronsivalle, Vincenzo
    Cicciu, Marco
    Minervini, Giuseppe
    BMC ORAL HEALTH, 2024, 24 (01)
  • [42] A comparative evaluation of physical properties of CAD/CAM complete denture resins- an in vitro study
    Ojasvini Arora
    Nabeel Ahmed
    Yuliia Siurkel
    Vincenzo Ronsivalle
    Marco Cicciù
    Giuseppe Minervini
    BMC Oral Health, 24
  • [43] CAD-CAM Fabricated Denture Base Resins: In Vitro Investigation of the Minimum Acceptable Denture Base Thickness
    Alaseef, Nawarah
    Albasarah, Sara
    Al Abdulghani, Hanan
    Al-Harbi, Fahad A.
    Gad, Mohammed M.
    Akhtar, Sultan
    Khan, Soban Q.
    Ateeq, Ijlal Shahrukh
    al-Qarni, Faisal D.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (09): : 799 - 805
  • [44] Bonding properties of heat-polymerized denture base resin to Ti-6Al-7Nb alloy
    Suzuki, T
    Takahashi, H
    Arksornnukit, M
    Oda, N
    Hirano, S
    DENTAL MATERIALS JOURNAL, 2005, 24 (04) : 530 - 535
  • [45] In Vitro Analysis of the Fracture Resistance of CAD/CAM Denture Base Resins
    Steinmassl, Otto
    Offermanns, Vincent
    Stoeckl, Wolfgang
    Dumfahrt, Herbert
    Grunert, Ingrid
    Steinmassl, Patricia-Anca
    MATERIALS, 2018, 11 (03):
  • [46] Evaluation of trueness in a denture base fabricated by using CAD-CAM systems and adaptation to the socketed surface of denture base: An in vitro study
    You, Seung-Min
    You, Seung-Gyu
    Lee, Beom-Il
    Kim, Ji-Hwan
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (01): : 108 - 114
  • [47] Effect of various staining beverages on the color stability of CAD/CAM PMMA denture teeth: An in vitro study
    Alouch, Ehab
    Karkoutly, Mawia
    Teriaky, Omar
    CLINICAL AND EXPERIMENTAL DENTAL RESEARCH, 2024, 10 (02):
  • [48] Investigation on the Potential Use of Polypropylene Mesh for the Reinforcement of Heat-Polymerized PMMA Denture Base Resin
    Yerliyurt, Kaan
    Egri, Sinan
    POLYMERS, 2022, 14 (16)
  • [49] Influence of methylmercaptan on the bonding strength of autopolymerizing reline resins to a heat-polymerized denture base resin
    Ohkubo, Takuya
    Oizumi, Makoto
    Kobayashi, Takuya
    DENTAL MATERIALS JOURNAL, 2009, 28 (04) : 426 - 432
  • [50] Mechanical properties and surface roughness of chitosan reinforced heat polymerized denture base resin
    Chander, Naveen Gopi
    Venkatraman, Jayaraman
    JOURNAL OF PROSTHODONTIC RESEARCH, 2022, 66 (01) : 101 - 108