Pilot study of circle sequence reverse osmosis for high-recovery water reuse in industry using tertiary effluent

被引:2
|
作者
Lee, Younggeun [1 ]
Kang, Weekwan [1 ]
Lee, Woonyoung [1 ]
Park, Min-Ju [1 ]
Kim, Jungbin [2 ,3 ,4 ,5 ]
机构
[1] SK Ecoplant, Water Solut Team, Hitech BU, Susong Bldg,Yulgok Ro 2-Gil 19, Seoul 03143, South Korea
[2] Wenzhou Kean Univ, Coll Sci Math & Technol, Ctr Sustainable Environm & Ecosyst Res, Dept Environm Sci, 88 Daxue Rd, Wenzhou 325060, Zhejiang, Peoples R China
[3] Kean Univ, Dorothy & George Hennings Coll Sci Math & Technol, Dept Environm & Sustainabil Sci, 1000 Morris Ave, Union, NJ 07083 USA
[4] Wenzhou Municipal Key Lab Appl Biomed & Biopharmac, Wenzhou 325060, Zhejiang, Peoples R China
[5] Coll Sci Math & Technol, Zhejiang Bioinformat Int Sci & Technol Cooperat Ct, Wenzhou 325060, Zhejiang, Peoples R China
关键词
Circle sequence reverse osmosis; Pilot study; High recovery; Water reuse; Tertiary effluent; Ultrapure water; DESALINATION; ENERGY;
D O I
10.1016/j.desal.2024.118480
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Water reuse has recently been emphasized to ensure a sustainable water supply in response to water scarcity challenges. Reverse osmosis (RO) is widely adopted in water reuse to produce high-quality water from wastewater. However, RO needs to achieve further improvements in recovery and reduce fouling formation, particularly in brackish water reuse conditions. The circle-sequence reverse osmosis (CSRO) system provides a novel solution to the limitations of conventional RO systems in water reuse applications, enabling high recovery while mitigating scaling and organic fouling. Although the benefits of CSRO have been explored in modeling studies, its performance in practice still needs to be evaluated. Therefore, this study examined the performance of a 40 m3/ d CSRO pilot plant to explore its implications for high-recovery water reuse in industry ( e.g., ultrapure water) using tertiary effluent from a sewage treatment plant. The CSRO system achieved a high recovery of up to 97.2 %, with a critical recovery rate of 93.2 %. The CSRO pilot plant operated for four weeks at a recovery of 79.1 % without chemical cleaning in place, exhibiting specific energy consumption (SEC) of 0.71 +/- 0.03 kWh/m3 and permeate conductivity of 33 +/- 2 mu S/cm. Operating parameters were further investigated to provide insights into CSRO performance and highlight its operational features. Lastly, the SEC of CSRO was compared to that of a two stage RO system, with CSRO achieving a reduction of approximately 12-14 % in SEC. The advantages of CSRO highlight its potential for high-recovery and high-quality water reuse with innovative RO technology.
引用
收藏
页数:8
相关论文
共 34 条
  • [31] Microwave heating system for CuFe2O4/rGO/PMS enhanced catalytic-oxidative pre-treatment, water, and salt recovery from reverse osmosis reject of textile industry effluent
    Ghosh, Alakananda
    Kumar, Mathava
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2024, 188 : 1009 - 1025
  • [32] Theoretical and experimental investigation of reverse osmosis (RO) desalination solar system using the solar panel, battery, and water turbine for high-pressure recovery of output brine
    Ramazanian, Saeed
    Aliehyaei, Mehdi
    Salimi, Mahmoud
    Najafizadeh, Mohammad Mehdi
    SOLAR ENERGY, 2023, 262
  • [33] Operation of Different Reverse Osmosis (RO) Membrane Modules for the Treatment of High-Strength Wastewater to Enhance the Recovery of Clean Water-A Case Study in Bac Ninh, Vietnam
    Ho, Ngo Anh Dao
    Nguyen, Van Hieu
    Babel, Sandhya
    SUSTAINABILITY, 2022, 14 (23)
  • [34] Pilot study on arsenic removal from groundwater using a small-scale reverse osmosis system-Towards sustainable drinking water production (vol 318, pg 671, 2016)
    Schmidt, Stefan-Andre
    Gukelberger, Ephraim
    Hermann, Mario
    Fiedler, Florian
    Grossmann, Benjamin
    Hoinkis, Jan
    Ghosh, Ashok
    Chatterjee, Debashis
    Bundschuh, Jochen
    JOURNAL OF HAZARDOUS MATERIALS, 2017, 324 : 797 - 797