Highly sensitive electrochemical determination of agomelatine in biological samples based on Cu nanoparticles/Schiff base network1 modified glassy carbon electrode: DFT and experimental studies

被引:2
|
作者
Ajdari, Beheshteh [1 ]
Madrakian, Tayyebeh [1 ]
Sarvestani, Mohammad Reza Jalali [1 ]
Afkhami, Abbas [1 ]
机构
[1] Bu Ali Sina Univ, Fac Chem & Petr Sci, Dept Analyt Chem, Hamadan 6517838695, Iran
关键词
Agomelatine; Square wave voltammetry; Electrochemical sensor; Density functional theory; Box-Behnken design; VOLTAMMETRIC DETERMINATION; ENERGY-STORAGE; HUMAN PLASMA; OPTIMIZATION; ADSORPTION; MICROEXTRACTION; QUANTIFICATION; NANOCOMPOSITE; SURFACTANTS; MELATONIN;
D O I
10.1016/j.talanta.2024.127174
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, a nanocomposite of copper nanoparticles incorporated into a covalent organic framework (Cu@SNW1) was synthesized and characterized by various approaches such as scanning electron microscopy, cyclic voltammetry, X-ray diffraction, electrochemical impedance spectroscopy, and energy dispersive X-ray spectroscopy. The interaction between the nanocomposite and agomelatine (AGM) was investigated through density functional theory computations. The results indicated that the nanocomposite displays electrocatalytic properties towards AGM and their interactions are both experimentally and thermodynamically viable. The synthesized nanocomposite was employed as an electrocatalytic modifier for the highly selective and sensitive square wave anodic stripping voltammetric detection of AGM. Experimental parameters including; pH, deposition time, modifier concentration, and deposition potential were fine-tuned using the Box-Behnken experimental design strategy. Under the optimal conditions, a linear correlation was established between the anodic peak current of AGM and its concentration across two linear ranges, 0.007-1.00 mu mol L- 1 and 1.00-6.50 mu mol L- 1 . The method demonstrated a limit of detection of 0.002 mu mol L- 1 under the optimized parameters. Furthermore, the proposed method exhibited high sensitivity and selectivity in determining AGM in urine, serum, and saliva samples.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Electrochemical Determination of Chlorophenaramine Based on RTIL/CNT Composite Modified Glassy Carbon Electrode in Pharmaceutical Samples
    Khan, Shirinaz I.
    Motghare, Ramani V.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2019, 166 (13) : B1202 - B1208
  • [22] Highly sensitive electrochemical sensor based on Pt nanoparticles/carbon nanohorns for simultaneous determination of morphine and MDMA in biological samples
    Zhang, Ruilin
    Fu, Kaixin
    Zou, Fangyuan
    Bai, Huiping
    Zhang, Genlin
    Liang, Feng
    Liu, Qingju
    ELECTROCHIMICA ACTA, 2021, 370
  • [23] Sensitive electrochemical determination of Sudan II in food samples using a poly(aminosulfonic acid) modified glassy carbon electrode
    Xinying Ma
    Mingyong Chao
    Russian Journal of Electrochemistry, 2013, 49 : 1057 - 1064
  • [24] Sensitive electrochemical determination of Sudan II in food samples using a poly(aminosulfonic acid) modified glassy carbon electrode
    Ma, Xinying
    Chao, Mingyong
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2013, 49 (11) : 1057 - 1064
  • [25] Ultrasensitive and highly selective electrochemical determination of mesalazine in pharmaceutical, biological and environmental samples with the use of Co-Mordenite/Mesoporous Carbon modified Glassy Carbon Electrode
    Fendrych, Katarzyna
    Porada, Radoslaw
    Bas, Boguslaw
    ELECTROCHIMICA ACTA, 2023, 468
  • [26] Electrochemical determination of glutathione based on an electrodeposited nickel oxide nanoparticles-modified glassy carbon electrode
    Yuan, Baiqing
    Zeng, Xiaoying
    Deng, Dehua
    Xu, Chunying
    Liu, Lin
    Zhang, Jiayu
    Gao, Yan
    Pang, Huan
    ANALYTICAL METHODS, 2013, 5 (07) : 1779 - 1783
  • [27] Highly sensitive electrochemical sensor for the food toxicant Sudan I based on a glassy carbon electrode modified with reduced graphene oxide decorated with Ag-Cu nanoparticles
    Yao, Youzhi
    Liu, Yunchun
    Yang, Zhousheng
    MICROCHIMICA ACTA, 2016, 183 (12) : 3275 - 3283
  • [28] Highly sensitive electrochemical sensor for the food toxicant Sudan I based on a glassy carbon electrode modified with reduced graphene oxide decorated with Ag-Cu nanoparticles
    Youzhi Yao
    Yunchun Liu
    Zhousheng Yang
    Microchimica Acta, 2016, 183 : 3275 - 3283
  • [29] Novel sensor for sensitive electrochemical determination of luteolin based on In2O3 nanoparticles modified glassy carbon paste electrode
    Ibrahim, Hossieny
    Temerk, Yassien
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 206 : 744 - 752
  • [30] Highly sensitive electrochemical determination of azathioprine using a glassy carbon electrode modified with Au neuronal-like nanostructures
    Mei, Li-Ping
    Feng, Jiu-Ju
    Huang, Su-Su
    Shi, Ya-Cheng
    Wang, Ai-Jun
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 240 : 996 - 1002