Evaluation of the effects of fenestration in Fontan circulation using a lumped parameter model

被引:0
|
作者
Horio, Naohiro [1 ,2 ]
Shimizu, Shuji [2 ,3 ]
Kotani, Yasuhiro [2 ]
Miyahara, Yoshinori [1 ]
Kasahara, Shingo [2 ]
机构
[1] Showa Univ Hosp, Pediat Heart Dis & Adult Congenital Heart Dis Ctr, Tokyo, Japan
[2] Okayama Univ, Grad Sch Med Dent & Pharmaceut Sci, Dept Cardiovasc Surg, Okayama, Japan
[3] Natl Cerebral & Cardiovasc Ctr, Dept Res Promot & Management, 6-1 Kishibe Shimmachi, Suita, Osaka 5648565, Japan
来源
JOURNAL OF PHYSIOLOGICAL SCIENCES | 2024年 / 74卷 / 01期
关键词
Single ventricle; Fontan circulation; Fenestration; Hemodynamic simulation; Lumped parameter model; TOTAL CAVOPULMONARY CONNECTION;
D O I
10.1186/s12576-024-00947-y
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Fenestration has been reported to enhance Fontan hemodynamics in several cases of Fontan circulation. However, the indication criteria for fenestration remain under discussion. To assess the effectiveness of fenestration in Fontan circulation, we conducted a theoretical analysis using a computational model of the fenestrated Fontan circulation. The cardiac chambers and vascular systems were modeled using the time-varying elastance model and the modified Windkessel model, respectively. When the pulmonary vascular resistance index was 4.01 Wood units m2, fenestration significantly reduced central venous pressure from 18.0 to 16.1 mmHg and decreased stressed blood volume from 610 to 555 ml. However, in the models with reduced ventricular end-systolic elastance, increased ventricular stiffness constant, or heightened systemic vascular resistance, the advantages of fenestration were diminished. Thus, fenestration may effectively improve the hemodynamics of Fontan circulation in patients with elevated pulmonary vascular resistance.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Effects of Transcatheter Closure of Fontan Fenestration on Exercise Tolerance
    Tarek S. Momenah
    Haifa Eltayb
    Reida El Oakley
    Howeida Al Qethamy
    Yahya Al Faraidi
    Pediatric Cardiology, 2008, 29 : 585 - 588
  • [32] Effects of transcatheter closure of Fontan fenestration on exercise tolerance
    Momenah, Tarek S.
    Eltayb, Haifa
    El Oakley, Reida
    Al Qethamy, Howeida
    Al Faraidi, Yahya
    PEDIATRIC CARDIOLOGY, 2008, 29 (03) : 585 - 588
  • [33] Parameter estimation for closed-loop lumped parameter models of the systemic circulation using synthetic data
    Bjordalsbakke, Nikolai L.
    Sturdy, Jacob T.
    Hose, David R.
    Hellevik, Leif R.
    MATHEMATICAL BIOSCIENCES, 2022, 343
  • [34] Monitoring variability in parameter estimates for lumped parameter models of the systemic circulation using longitudinal hemodynamic measurements
    Nikolai L. Bjørdalsbakke
    Jacob Sturdy
    Emma M. L. Ingeström
    Leif R. Hellevik
    BioMedical Engineering OnLine, 22
  • [35] Parameter estimation for closed-loop lumped parameter models of the systemic circulation using synthetic data
    Bjørdalsbakke, Nikolai L.
    Sturdy, Jacob T.
    Hose, David R.
    Hellevik, Leif R.
    Mathematical Biosciences, 2022, 343
  • [36] Monitoring variability in parameter estimates for lumped parameter models of the systemic circulation using longitudinal hemodynamic measurements
    Bjordalsbakke, Nikolai L.
    Sturdy, Jacob
    Ingestrom, Emma M. L.
    Hellevik, Leif R.
    BIOMEDICAL ENGINEERING ONLINE, 2023, 22 (01)
  • [37] Using the Amplatzer™ Septal Occluder to occlude fontan fenestration
    Coe, JY
    Dyck, JD
    Olley, PM
    Harder, J
    PEDIATRIC RESEARCH, 2000, 47 (04) : 40A - 40A
  • [38] Fontan fenestration closure using the amplatzer septal occluder
    Cowley, CG
    Badran, S
    Rocchini, AP
    Lloyd, TR
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (02) : 498A - 498A
  • [39] EVALUATION OF THE BENEFITS IN HEAT PUMP DESIGN WHEN USING A DYNAMIC LUMPED-PARAMETER MODEL
    Lepore, R.
    Remy, M.
    Dumont, E.
    Frere, M.
    23RD IIR INTERNATIONAL CONGRESS OF REFRIGERATION, 2011, 23 : 2344 - 2351
  • [40] Evaluation of dynamical behavior of Thorium fueled SMART reactor using lumped parameter dynamic model
    Melikkendli, Behram
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2025, 57 (04)