A method for configuring hybrid electrolyzers based on joint wind and photovoltaic power generation modeling using copula functions

被引:0
|
作者
Liang, Yuan [1 ]
Ma, Haoyuan [1 ]
Liang, Zhonghao [2 ]
Wang, Hongqing [1 ]
Li, Jianlin [2 ]
机构
[1] Beijing Forestry Univ, Coll Sci, Beijing 100083, Peoples R China
[2] North China Univ Technol, Natl User Side Energy Storage Innovat Res & Dev Ct, Beijing 100144, Peoples R China
来源
SUSTAINABLE ENERGY GRIDS & NETWORKS | 2024年 / 40卷
基金
中国国家自然科学基金;
关键词
Copula function; Ensemble empirical mode decomposition; Wind and photovoltaic power generation; Hybrid electrolyzer configuration; Optimal proportioning;
D O I
10.1016/j.segan.2024.101539
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Considering the specific wind and photovoltaic power characteristics of a certain region, this study investigates the optimal ratio of Alkaline Electrolysis Cells (AEL) to Proton Exchange Membrane (PEM) electrolyzers in a hybrid electrolysis system for hydrogen production. A flexible model for configuring the hybrid electrolysis system is proposed, based on a copula function for joint wind and solar power modeling. This model generates wind and photovoltaic power generation scenarios using the copula function, incorporating a selection mechanism to ensure that the output scenarios are more representative of the actual data characteristics of wind and photovoltaic power output. Consequently, considering both the fluctuation and amplitude, the wind and photovoltaic power data are decomposed using the Ensemble empirical mode decomposition method. The decomposed components are then allocated to the two types of electrolyzers. Furthermore, the optimal configuration of the hybrid electrolysis system is determined by minimizing the costs associated with wasted power, electricity purchases, and other expenses. Finally, a case study of a 100 MW wind farm and a 50 MW photovoltaic power station in Northwest China is presented, concluding that the optimal configuration ratio of AEL to PEM electrolyzers is 2:1. In a Matlab/Simulink platform, the performance metrics of the hybrid electrolysis system were validated. It was found that the hydrogen production rate of the hybrid electrolyzer is comparable to that of the PEM electrolyzer, but with a lower required cost. Additionally, the hydrogen production rate and volume of the optimal configuration for the hybrid electrolyzer determined by the model proposed in this paper are higher than those obtained through the optimization algorithm's optimal configuration.
引用
收藏
页数:17
相关论文
共 50 条
  • [31] A scenario generation method based on the mixture vine copula and its application in the power system with wind/hydrogen production
    Qiu, Yibin
    Li, Qi
    Pan, Yuru
    Yang, Hanqing
    Chen, Weirong
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2019, 44 (11) : 5162 - 5170
  • [32] Modeling and Equivalence of Integrated Power Generation System of Wind, Photovoltaic and Energy Storage
    Wang Haohuai
    Tang Yong
    Chen Jing
    Hou Junxian
    2012 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2012,
  • [33] Solar Energy Power of Grid-independent Hybrid Photovoltaic/Wind Power Generation System
    Ren, Da-Jiang
    THEORETICAL AND METHODOLOGICAL APPROACHES TO SOCIAL SCIENCE, ECONOMICS AND MANAGEMENT SCIENCE, 2015, : 494 - 498
  • [34] Optimal scheduling of wind-photovoltaic power-generation system based on a copula-based conditional value-at-risk model
    Ju, Xin
    Liu, Xiaomin
    Liu, Shangke
    Xiao, Yangli
    CLEAN ENERGY, 2022, 6 (04): : 550 - 556
  • [35] Correlation modeling of power output among multiple wind farms based on scenario D vine Copula method
    Qiu, Yibin
    Li, Shihan
    Liu, Lu
    Wang, Yong
    Li, Qi
    Chen, Weirong
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2019, 40 (10): : 2960 - 2966
  • [36] Research on wind speed forecasting method based on hybrid Copula optimization algorithm
    Huang Y.
    Zhang B.
    Pang H.
    Xu J.
    Liu L.
    Wang B.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2022, 43 (10): : 192 - 201
  • [37] Reliability assessment of wind-PV hybrid generation system based on Copula theory
    Zhao, Jichao
    Yuan, Yue
    Fu, Zhixin
    Sun, Chunjun
    Qian, Kang
    Xu, Wenchao
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2013, 33 (01): : 124 - 129
  • [38] Copula-based modeling of stochastic wind power in Europe and implications for the Swiss power grid
    Hagspiel, Simeon
    Papaemannouil, Antonis
    Schmid, Matthias
    Andersson, Goeran
    APPLIED ENERGY, 2012, 96 : 33 - 44
  • [39] Mid-to-long term wind and photovoltaic power generation prediction based on copula function and long short term memory network
    Han, Shuang
    Qiao, Yan-hui
    Yan, Jie
    Liu, Yong-qian
    Li, Li
    Wang, Zheng
    APPLIED ENERGY, 2019, 239 : 181 - 191
  • [40] Modeling of Joint Rainfall Rate and Rain Attenuation Statistics Using Archimedean Copula Functions
    Kourogiorgas, Charilaos I.
    Livieratos, Spiros N.
    Panagopoulos, Athanasios D.
    Chatzarakis, George E.
    2014 8TH EUROPEAN CONFERENCE ON ANTENNAS AND PROPAGATION (EUCAP), 2014, : 509 - +