Early screening of lung function by electrical impedance tomography in people with normal spirometry reveals unrecognized pathological features

被引:0
|
作者
Qu, Shuoyao [1 ]
Feng, Enzhi [2 ]
Dong, Daihan [1 ]
Yang, Lin [3 ]
Dai, Meng [4 ]
Frerichs, Inez [5 ]
Liu, Shaojie [2 ]
Gao, Yi [6 ]
Zheng, Jinping [6 ]
Song, Liqiang [1 ]
Zhao, Zhanqi [6 ,7 ,8 ]
机构
[1] Air Force Med Univ, Xijing Hosp, Dept Pulm & Crit Care Med, Xian, Peoples R China
[2] 941 Hosp Joint Support Force Peoples Liberat Army, Xining, Peoples R China
[3] Air Force Med Univ, Dept Aerosp Med, Xian, Peoples R China
[4] Air Force Med Univ, Dept Biomed Engn, Xian, Peoples R China
[5] Univ Med Ctr Schleswig, Dept Anesthesiol & Intens Care Med, Holstein Campus Kiel, Kiel, Germany
[6] Guangzhou Med Univ, Affiliated Hosp 1, Guangzhou Inst Resp Hlth, Dept Pulm & Crit Care Med, Guangzhou, Peoples R China
[7] Guangzhou Med Univ, Sch Biomed Engn, Guangzhou, Peoples R China
[8] Chinese Acad Med Sci, Peking Union Med Coll Hosp, Dept Crit Care Med, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
VENTILATION; EIT;
D O I
10.1038/s41467-024-55505-2
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Early detection of lung function impairment is crucial. However, the sensitivity of spirometry in detecting early lung function deterioration is limited. In this study, lungs of 3180 healthy participants scheduled for annual health check were screened. Electrical impedance tomography measurements were conducted in 130 participants with normal spirometry for concept establishment phase and 105 for validation phase. A follow-up CT examination was suggested for participants with abnormal regional time constant or tobacco consumption >= 10 pack-years. Using CT as reference, the sensitivity and specificity of electrical impedance tomography-based screening were 81.3% and 50.0%, respectively in the concept establishment phase. In the validation phase, the sensitivity and specificity were 77.9% and 50.0%. In this study we show that conventional spirometry may not capture early changes that occur at a regional level. The regional time constant based on electrical impedance tomography can be a promising tool for early screening of lung function impairment. Clinical trial registration: ChiCTR2300076673, www.chictr.org.cn.
引用
收藏
页数:9
相关论文
共 47 条
  • [21] Evaluation Of Function And Regional Lung Ventilation Of Morbidly Obese Women Through The Electrical Impedance Tomography
    Silva, S. A.
    Brandao, D. C.
    Goncalves, A. C. E.
    Couto, A. S.
    Morais, C. C. A.
    Rattes, C.
    Campos, S. L.
    Dornelas De Andrade, A.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2017, 195
  • [22] Late Breaking Abstract - Electrical Impedance Tomography (EIT) determines the pulmonary ventilation heterogeneity in patients with normal and preserved ratio impairment of lung function
    Ge, Huiqing
    Li, Jiayi
    Zhao, Zhanqi
    EUROPEAN RESPIRATORY JOURNAL, 2024, 64
  • [23] Regional lung function determined by electrical impedance tomography during bronchodilator reversibility testing in patients with asthma
    Frerichs, I.
    Zhao, Z.
    Becher, T.
    Zabel, P.
    Weiler, N.
    Vogt, B.
    PHYSIOLOGICAL MEASUREMENT, 2016, 37 (06) : 698 - 712
  • [24] Dynamic Electrical Impedance Tomography Image Reconstruction of Neonate Lung Function based on Linear Kalman Filter techniques
    El Dib, Hussein
    Tizzard, Andrew
    Bayford, Richard
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 4: IMAGE PROCESSING, BIOSIGNAL PROCESSING, MODELLING AND SIMULATION, BIOMECHANICS, 2010, 25 : 1643 - 1645
  • [25] Spatial and temporal heterogeneity of regional lung ventilation determined by electrical impedance tomography during pulmonary function testing
    Vogt, Barbara
    Pulletz, Sven
    Elke, Gunnar
    Zhao, Zhanqi
    Zabel, Peter
    Weiler, Norbert
    Frerichs, Inez
    JOURNAL OF APPLIED PHYSIOLOGY, 2012, 113 (07) : 1154 - 1161
  • [26] Affordable, portable and self-administrable electrical impedance tomography enables global and regional lung function assessment
    Fedi Zouari
    Wei Yi Oon
    Dipyaman Modak
    Wing Hang Lee
    Wang Chun Kwok
    Peng Cao
    Wei-Ning Lee
    Terence Chi Chun Tam
    Eddie C. Wong
    Russell W. Chan
    Scientific Reports, 12
  • [27] Deep learning based reconstruction enables high-resolution electrical impedance tomography for lung function assessment
    Zeng, Shihao
    Kwole, Wang Chun
    Cao, Peng
    Zouari, Fedi
    Lee, Philip Tin Yun
    Chan, Russell W.
    Touboul, Adrien
    2023 45TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY, EMBC, 2023,
  • [28] Regional lung function measures determined by electrical impedance tomography during repetitive ventilation manoeuvres in patients with COPD
    Lasarow, L.
    Vogt, B.
    Zhao, Z.
    Balke, L.
    Weiler, N.
    Frerichs, I
    PHYSIOLOGICAL MEASUREMENT, 2021, 42 (01)
  • [29] Global and regional lung function assessment using portable electrical impedance tomography (EIT) system: clinical study
    Zouari, Fedi
    Cheung, Pak To
    Touboul, Adrien
    Kwok, Wang C.
    Sin, Venice
    Wong, Eddie C.
    Zhou, Iris Y.
    Tam, Terence C. C.
    Chan, Russell W.
    2023 45TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY, EMBC, 2023,
  • [30] Affordable, portable and self-administrable electrical impedance tomography enables global and regional lung function assessment
    Zouari, Fedi
    Oon, Wei Yi
    Modak, Dipyaman
    Lee, Wing Hang
    Kwok, Wang Chun
    Cao, Peng
    Lee, Wei-Ning
    Tam, Terence Chi Chun
    Wong, Eddie C.
    Chan, Russell W.
    SCIENTIFIC REPORTS, 2022, 12 (01)