Experimental and analytical study on axial behaviour of square corrugated concrete filled single and double skin tube stub columns

被引:0
|
作者
Handousa, Aya Mohsen [1 ,2 ]
Abdellatief, Mohamed [1 ]
Salem, Fikry Abdo [2 ]
Mahmoud, Nabil [2 ]
Ghannam, Mohamed [2 ]
机构
[1] Higher Future Inst Engn & Technol Mansoura, Dept Struct Engn, Mansoura, Egypt
[2] Mansoura Univ, Fac Engn, Dept Struct Engn, Mansoura, Egypt
来源
SCIENTIFIC REPORTS | 2025年 / 15卷 / 01期
关键词
Corrugated concrete-filled steel tubes; Corrugated-columns; Square CFDST columns; Ultimate axial strength; Internal square tubes; COMPRESSIVE BEHAVIOR; CFDST COLUMNS; STEEL TUBES; PREDICTION; SECTIONS;
D O I
10.1038/s41598-025-85585-z
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Concrete-filled double-skin steel tubular (CFDST) columns have become widely utilized in building construction and bridges, thanks to their exceptional structural capabilities. Therefore, this study investigates the axial compressive behavior of square CFDST columns. The study aims to explore the influence of external and internal plate shapes (flat or corrugated plates) and different widths of internal steel tubes on the axial compressive behavior. The effects of varying internal widths of the internal steel tube (60 mm, 116 mm, and 160 mm) on the performance of CFDST columns were examined. Additionally, the study compared the performance of concrete-filled steel tubular (CFST) and CFDST columns with external flat or corrugated plates. The findings indicated that incorporating internal corrugated plates notably improved both the load-carrying capacity and ductility of the specimens. Notably, CFDST columns featuring corrugated internal plates (116 mm width) exhibited strength enhancements of 25.3% and 7.4% compared to internal widths of 160 mm and 60 mm, respectively. Furthermore, the study proposed two machine-learning models, namely Artificial Neural Network (ANN) and Gaussian Process Regression (GPR), to estimate the ultimate compressive strength of square CFDST columns. The findings indicated that the GPR model outperformed the ANN model in predicting the bearing capacity of square CFDST columns. Additionally, the Shapley Additive Explanation technique was employed for feature analysis. The outcomes of this analysis revealed that parameters such as section width and concrete strength positively influence the compressive strength index.
引用
收藏
页数:26
相关论文
共 50 条
  • [21] Axial compression behaviour of concrete filled double skin steel tube columns anchored with orbicular rings: Experimental and numerical approach
    Singh, Harpreet
    Tiwary, Aditya Kumar
    ADVANCES IN STRUCTURAL ENGINEERING, 2023, 26 (15) : 2830 - 2861
  • [22] Axial compressive behavior of stone encased concrete-filled square steel tube stub columns
    Liu, Yang
    Liu, Jie
    Liu, Xiaojuan
    Zhang, Chaozhong
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2025, 224
  • [23] Axial behavior of concrete-filled double skin steel tubular stub columns filled with demolished concrete lump
    Wang, Yanze
    Li, Baishou
    MECHATRONICS ENGINEERING, COMPUTING AND INFORMATION TECHNOLOGY, 2014, 556-562 : 671 - 674
  • [24] Behaviour of restrained concrete filled square double-skin and double-tube hollow columns in case of fire
    Lopes, Ruben F. R.
    Rodrigues, Joao Paulo C.
    ENGINEERING STRUCTURES, 2020, 216
  • [25] Finite Element Analysis on Axial Bearing Capacity of Square Double Skin Steel Stub Short Columns Filled with Recycled Concrete
    Bing, Song
    Shou, Li Bai
    PROCEEDINGS OF THE 2016 INTERNATIONAL CONFERENCE ON EDUCATION, MANAGEMENT, COMPUTER AND SOCIETY, 2016, 37 : 1538 - 1543
  • [26] Behaviour of square concrete-filled stiffened steel tubular stub columns under axial compression
    Yuan, Fang
    Huang, Hong
    Chen, Mengcheng
    ADVANCES IN STRUCTURAL ENGINEERING, 2019, 22 (08) : 1878 - 1894
  • [27] Axial compression behaviour of CFRP confined reactive power concrete filled steel tube stub columns
    Jiao C.
    Li S.
    Cui L.
    Wang Z.
    Jian C.
    Fuhe Cailiao Xuebao/Acta Materiae Compositae Sinica, 2021, 38 (02): : 439 - 448
  • [28] Post-fire axial load resistance of concrete-filled, double-skin tube (CFDST) stub columns
    Imani, Reza
    Bruneau, Michel
    Engineering Journal, 2018, 55 (04): : 203 - 208
  • [29] Post-Fire Axial Load Resistance of Concrete-Filled, Double-Skin Tube (CFDST) Stub Columns
    Imani, Reza
    Bruneau, Michel
    ENGINEERING JOURNAL-AMERICAN INSTITUTE OF STEEL CONSTRUCTION, 2018, 55 (04): : 203 - 207
  • [30] Experimental and numerical behaviour of eccentrically loaded high strength concrete filled high strength square steel tube stub columns
    Li, Guochang
    Chen, Bowen
    Yang, Zhijian
    Feng, Yihe
    THIN-WALLED STRUCTURES, 2018, 127 : 483 - 499