Diagnostic efficacy of dual-energy CT virtual non-calcium technique in the diagnosis of bone marrow edema of sacroiliac joints in ankylosing spondylitis

被引:1
|
作者
Lu, Hongyue [1 ,2 ]
Li, Zhi [2 ,3 ]
Liang, Ziheng [1 ,2 ]
Liu, Yuqi [1 ,2 ]
机构
[1] Kunming Univ Sci & Technol, Med Sch, Kunming, Yunnan, Peoples R China
[2] First Peoples Hosp Yunnan Prov, Dept Radiol, Kunming, Yunnan, Peoples R China
[3] Kunming Univ Sci & Technol, Affiliated Hosp, Kunming, Yunnan, Peoples R China
来源
关键词
DECT VNCa; Ankylosing spondylitis; Bone marrow edema of the sacroiliac joints; Diagnostic efficacy;
D O I
10.1186/s13018-024-05341-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective In-depth investigation of the diagnostic performance of dual-energy CT (DECT) virtual non-calcium (VNCa) technique for sacroiliac joint bone marrow edema (BME) in patients with ankylosing spondylitis(AS). Methods A total of 42 patients with AS)who underwent sacroiliac joint MRI and DECT scans on the same day at our Rheumatology and Immunology Department between August 2022 and June 2023 were selected. Using MRI as the reference standard, the presence of BME on the iliac and sacral surfaces was evaluated, resulting in the categorization of patients into BME-positive and BME-negative groups. Subsequently, the DECT scan data was processed using the "Bone Marrow" algorithm to generate VNCa color-coded images of the bone marrow. The diagnostic performance of DECT in detecting BME was assessed through visual qualitative evaluation and objective quantitative analysis. Results Visual qualitative assessment analysis showed good agreement between the results of BME analysis on virtual non-calcium images and MRI images by both physicians (Kappa > 0.61). The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of visual qualitative assessment for BME by Physicians A and B were as follows: iliac facet [(92.5%, 88.6%, 88.1%, 92.9%, 90.5%), (90.0%, 90.9%, 90.0%, 90.9%, 90.5%)], sacral facet [(88.4%, 87.8%, 88.4%, 87.8%, 88.1%), (90.7%, 85.3%, 86.7%, 89.7%, 88.1%)].In terms of objective quantitative analysis, the CT values of the edematous areas on the iliac and sacral surfaces were (-41.4 +/- 15.9) Hu and (-38.8 +/- 19.7) Hu, respectively, while the CT values of normal bone marrow areas were (-79.6 +/- 18.2) Hu and (-72.8 +/- 14.8) Hu, respectively. The CT values of the edematous areas were higher than those of the non-edematous areas. Based on the receiver operating characteristic curve analysis, the area under the curve for the iliac and sacral surfaces were 0.90 and 0.89, respectively. The optimal CT cutoff values were - 57.4 Hu and - 56.8 Hu, with corresponding sensitivities of 92.5% and 86.4% and specificities of 90.7% and 87.8%. Conclusion The DECT VNCa technique has a high diagnostic efficacy in the diagnosis of BME in the sacroiliac joints in ankylosing spondylitis in terms of visual qualitative assessment and objective quantitative analysis.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Bone Marrow Edema at Dual-Energy CT: A Game Changer in the Emergency Department
    Gosangi, Babina
    Mandell, Jacob C.
    Weaver, Michael J.
    Uyeda, Jennifer W.
    Smith, Stacy E.
    Sodickson, Aaron D.
    Khurana, Bharti
    RADIOGRAPHICS, 2020, 40 (03) : 859 - 874
  • [42] Multiple Myeloma and Dual-Energy CT: Diagnostic Accuracy of Virtual Noncalcium Technique for Detection of Bone Marrow Infiltration of the Spine and Pelvis
    Kosmala, Aleksander
    Weng, Andreas Max
    Heidemeier, Anke
    Krauss, Bernhard
    Knop, Stefan
    Bley, Thorsten Alexander
    Petritsch, Bernhard
    RADIOLOGY, 2018, 286 (01) : 205 - 213
  • [43] Quantitative evaluation of the effects of dual-energy CT acquisition, reconstruction and postprocessing parameters on virtual Non-Calcium (VNCa) images
    Wellenberg, R. H. H.
    Ahmed, R.
    Mueller, F. C.
    Boesen, M.
    Faby, S.
    Maas, M.
    Jurgens, M.
    Streekstra, G. J.
    EUROPEAN JOURNAL OF RADIOLOGY, 2025, 182
  • [44] Detection of Bone Marrow Edema in Nondisplaced Hip Fractures: Utility of a Virtual Noncalcium Dual-Energy CT Application
    Kellock, Trenton T.
    Nicolaou, Savvas
    Kim, Sandra S. Y.
    Al-Busaidi, Sultan
    Louis, Luck J.
    O'Connell, Tim W.
    Ouellette, Hugue A.
    McLaughlin, Patrick D.
    RADIOLOGY, 2017, 284 (03) : 798 - 805
  • [45] Dual-Energy CT: Virtual Calcium Subtraction for Assessment of Bone Marrow Involvement of the Spine in Multiple Myeloma
    Thomas, Christoph
    Schabel, Christoph
    Krauss, Bernhard
    Weisel, Katja
    Bongers, Malte
    Claussen, Claus D.
    Horger, Marius
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (03) : W324 - W331
  • [46] Dual-energy computed tomography for the detection of sacroiliac joints bone marrow oedema in patients with axial spondyloarthritis
    Carotti, M.
    Benfaremo, D.
    Di Carlo, M.
    Ceccarelli, L.
    Luchetti, M. M.
    Piccinni, P.
    Giovagnoni, A.
    Salaffi, F.
    CLINICAL AND EXPERIMENTAL RHEUMATOLOGY, 2021, 39 (06) : 1316 - 1323
  • [47] Quantification of bone marrow edema using dual-energy CT at fracture sites in trauma
    Abbassi, Mashya
    Jain, Ashwin
    Shin, Donghoon
    Arasa, Carlota Andreu
    Li, Baojun
    Anderson, Stephan W.
    LeBedis, Christina A.
    EMERGENCY RADIOLOGY, 2022, 29 (04) : 691 - 696
  • [48] Quantification of bone marrow edema using dual-energy CT at fracture sites in trauma
    Mashya Abbassi
    Ashwin Jain
    Donghoon Shin
    Carlota Andreu Arasa
    Baojun Li
    Stephan W. Anderson
    Christina A. LeBedis
    Emergency Radiology, 2022, 29 : 691 - 696
  • [49] Good interrater reliability of a new grading system in detecting traumatic bone marrow lesions in the knee by dual energy CT virtual non-calcium images
    Cao, Jian-xin
    Wang, Yi-min
    Kong, Xiang-quan
    Yang, Cheng
    Wang, Peng
    EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (06) : 1109 - 1115
  • [50] Diagnostic performance of electron-density dual-energy CT in detection of cervical disc herniation in comparison with standard gray-scale CT and virtual non-calcium images
    Shim, Euddeum
    Kim, Baek Hyun
    Kang, Woo Young
    Hong, Suk-Joo
    Kang, Chang Ho
    Ahn, Kyung-Sik
    Lee, Hyeonbin
    Kwack, Thomas J.
    EUROPEAN RADIOLOGY, 2022, 32 (04) : 2209 - 2220